logo

IEC 60884-1 2022 Test Set Up For Plugs And Sockets Temperature Rise Test

Basic Properties
Place of Origin: China
Brand Name: Sinuo
Certification: Calibration Certificate(cost additional )
Model Number: SN2119
Trading Properties
Minimum Order Quantity: 1 Set
Price: Negotiable
Payment Terms: T/T
Supply Ability: 10 Sets / Month
Specifications
Test stations: 2 Stations Channels: 8 Channels
Test current: 0-60A Test voltage: <12V
Humidity: 30%-90% Timing: Can Be Selected
Working temperature: 0-40℃ Digital value: ±0.5%FC±2d
High Light:

IEC 60884-1 2022 Test Set Up

,

Plugs And Sockets Test Set Up

Product Description

 

IEC 60884-1: 2022 Test Set Up For Plugs And Sockets Temperature Rise Test

 

Product Information For Test Set Up:

 

The device is made and manufactured according to the related standard requirement of temperature rising, such as IEC 60884-1:2022 clause 19, IEC 60669-1:2017 Clause 17, VDE0620 etc. It is applicable to the temperature rising of electronic accessories in working position.

 

Technical parameters For Test Set Up:

 

Model SN2119
Test stations 2 stations are independently adjustable, each group has two outputs in series
Test current 0-60A
Test voltage <12V
Digital display current value Accuracy: ±0.5%FC±2d
Timing Digital display, range 0~99.99s~99.99m~99.99h can be selected, alarm when time arrives
Temperature measurement Adopt temperature inspection instrument, 8 channels, LCD digital display, with temperature-time curve
Power supply AC220V±10%/50-60Hz
Standard IEC 60884-1
Test samples Plug and socket-outlets
 

Applications For Test Set Up:

 

Samples Household appliance plugs and sockets
Test purpose Test the temperature rise of electrical accessories under working conditions
Test principle Use voltage and current to simulate the normal use of the workpiece, and measure the temperature rise after a certain period of time
Equipment structure and characteristics

External type, with built-in temperature measuring meter, the thermocouple wire is directly connected to the sample

Equipment dimensions: about: 600 × 600 × 600 (mm) W × D × H, equipment weight: 100kg

Use environmental Power supply: AC220V±10%/50-60Hz, working temperature 0-40℃, humidity 30%-90%.
 

IEC 60884-1 2022 Test Set Up For Plugs And Sockets Temperature Rise Test

 

IEC 60884-1 2022 Test Set Up For Plugs And Sockets Temperature Rise Test