Send Message
products
PRODUCTS DETAILS
Home > Products >
IEC 60884-1 2022 Load Cabinet For Plug And Socket Normal Operation Life Test

IEC 60884-1 2022 Load Cabinet For Plug And Socket Normal Operation Life Test

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 20 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2117A
Test Station:
2 Stations
Load Capacity:
2*15KVA
Digital Voltmeter:
0~300V, Accuracy ±0.5%
Digital Ammeter:
0~40A, Accuracy ±0.5%
Capacitive Load:
70uf, 140uf, 7.3uf, Switchable
Load Mode:
Resistive, Inductive, Capacitive
Output Voltage:
300V
Output Current:
42A
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
20 sets per month
High Light:

IEC 60884-1 2022 Load Cabinet

,

Plug And Socket Load Cabinet

Product Description

 

IEC 60884-1: 2022 Load Cabinet For Plug And Socket Normal Operation Life Test

 

Product Information For Load Cabinet:

 

This load cabinet conforms to Standards of IEC 60669-1:2017 clause 18 and 19, IEC 60884-1 2013 clause 20 and 21, IEC 60950-1, IEC 60598-1, IEC61058-1 and so on

 

This device is used for household and similar purpose fixed electrical appliance switch, plug and socket, coupler for on-off ability, breaking capacity and normal operation life test.

 

The top of this apparatus is the operation control panel on which there are switches for controlling power supply, for the electric capacity conversion and for the load type conversion. There are also the displaying meters of connecting current and voltage as well as power, the buttons of start and stop, alarm, the status indicator light and so on. Below are the according knobs for output voltage adjustment, for current adjustment and for inductance adjustment. There are two stations, each station has the function of resistive, inductive and capacitive Load test. The kind of load test can be chosen by the transferring switch. The inside of load cabinet is cooled by the strong wind convection. There are terminals below the near cabinet through which the load cabinet can be connected with the switch and plug-socket endurance tester using the cables. During the process of test, the equipment outputs the current and voltage to test sample.

 

Technical Parameters For Load Cabinet:

 

No.: Item Parameters
1 Power supply Single phase AC220V/50Hz with ground wire
2 Channel 2 stations
3 Digital voltmeter 0~300V, accuracy ±0.5%
4 Digital ammeter 0~40A, accuracy ±0.5%
5 Digital display power meter 0~15KW, accuracy ±0.5%
6 Digital display power factor meter 0.3~0.98, accuracy ±0.5%
7 Load mode Resistive, inductive, capacitive three in one, switchable
8 Capacitive load 70uf, 140uf, 7.3uf can be switchable
9 Load output mode Each power (continuous) / interval power can be switchable
10 Timer 0~999999 times, can be preset
11 Load power capacity 2*15KVA
12 Upper limit of output current 42A, when it exceeds 42A, it will cut off automatically
13 Max. of the output voltage 300V, when it exceeds 305V, it stopped automatically
14 Operating environment Temperature: + 5 ~ + 40 ℃; relative humidity: (20 ~ 90)% RH; atmospheric pressure: 80 ~ 106kpa; no severe shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gas, good heat dissipation.
15 Equipment dimension & weight L 860 mm * W 810 mm * H 1880 mm, 455KGS
 
Precautions For Load Cabinet:
 

1 Due to the large capacity of this machine, a separate power connection is required, do not share a power supply with other equipment. It is best to connect a three-phase leakage protection switch with a current range of 63A to the machine.

2 This machine uses a single-phase AC220V/50Hz power supply with ground wire.

3 Because the voltage between the contacts of the sample can reach AC300V, and the maximum current is 42A, non-operators cannot touch the sample (switch) during test to prevent personal safety (electric shock). Before replacing the sample, please turn off the main power switch.

4 This machine generates a lot of heat, and there is a heat dissipation fan on the top of the load cabinet. Please do not place any debris so that the heat dissipation fan can dissipate heat.

5 When the counter reaches the preset number of tests, an alarm will sound to indicate that the test is complete. Press the "RST" button on the counter to clear the alarm.

 

IEC 60884-1 2022 Load Cabinet For Plug And Socket Normal Operation Life Test 0


IEC 60884-1 2022 Load Cabinet For Plug And Socket Normal Operation Life Test 1

products
PRODUCTS DETAILS
IEC 60884-1 2022 Load Cabinet For Plug And Socket Normal Operation Life Test
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 20 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2117A
Test Station:
2 Stations
Load Capacity:
2*15KVA
Digital Voltmeter:
0~300V, Accuracy ±0.5%
Digital Ammeter:
0~40A, Accuracy ±0.5%
Capacitive Load:
70uf, 140uf, 7.3uf, Switchable
Load Mode:
Resistive, Inductive, Capacitive
Output Voltage:
300V
Output Current:
42A
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
20 sets per month
High Light

IEC 60884-1 2022 Load Cabinet

,

Plug And Socket Load Cabinet

Product Description

 

IEC 60884-1: 2022 Load Cabinet For Plug And Socket Normal Operation Life Test

 

Product Information For Load Cabinet:

 

This load cabinet conforms to Standards of IEC 60669-1:2017 clause 18 and 19, IEC 60884-1 2013 clause 20 and 21, IEC 60950-1, IEC 60598-1, IEC61058-1 and so on

 

This device is used for household and similar purpose fixed electrical appliance switch, plug and socket, coupler for on-off ability, breaking capacity and normal operation life test.

 

The top of this apparatus is the operation control panel on which there are switches for controlling power supply, for the electric capacity conversion and for the load type conversion. There are also the displaying meters of connecting current and voltage as well as power, the buttons of start and stop, alarm, the status indicator light and so on. Below are the according knobs for output voltage adjustment, for current adjustment and for inductance adjustment. There are two stations, each station has the function of resistive, inductive and capacitive Load test. The kind of load test can be chosen by the transferring switch. The inside of load cabinet is cooled by the strong wind convection. There are terminals below the near cabinet through which the load cabinet can be connected with the switch and plug-socket endurance tester using the cables. During the process of test, the equipment outputs the current and voltage to test sample.

 

Technical Parameters For Load Cabinet:

 

No.: Item Parameters
1 Power supply Single phase AC220V/50Hz with ground wire
2 Channel 2 stations
3 Digital voltmeter 0~300V, accuracy ±0.5%
4 Digital ammeter 0~40A, accuracy ±0.5%
5 Digital display power meter 0~15KW, accuracy ±0.5%
6 Digital display power factor meter 0.3~0.98, accuracy ±0.5%
7 Load mode Resistive, inductive, capacitive three in one, switchable
8 Capacitive load 70uf, 140uf, 7.3uf can be switchable
9 Load output mode Each power (continuous) / interval power can be switchable
10 Timer 0~999999 times, can be preset
11 Load power capacity 2*15KVA
12 Upper limit of output current 42A, when it exceeds 42A, it will cut off automatically
13 Max. of the output voltage 300V, when it exceeds 305V, it stopped automatically
14 Operating environment Temperature: + 5 ~ + 40 ℃; relative humidity: (20 ~ 90)% RH; atmospheric pressure: 80 ~ 106kpa; no severe shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gas, good heat dissipation.
15 Equipment dimension & weight L 860 mm * W 810 mm * H 1880 mm, 455KGS
 
Precautions For Load Cabinet:
 

1 Due to the large capacity of this machine, a separate power connection is required, do not share a power supply with other equipment. It is best to connect a three-phase leakage protection switch with a current range of 63A to the machine.

2 This machine uses a single-phase AC220V/50Hz power supply with ground wire.

3 Because the voltage between the contacts of the sample can reach AC300V, and the maximum current is 42A, non-operators cannot touch the sample (switch) during test to prevent personal safety (electric shock). Before replacing the sample, please turn off the main power switch.

4 This machine generates a lot of heat, and there is a heat dissipation fan on the top of the load cabinet. Please do not place any debris so that the heat dissipation fan can dissipate heat.

5 When the counter reaches the preset number of tests, an alarm will sound to indicate that the test is complete. Press the "RST" button on the counter to clear the alarm.

 

IEC 60884-1 2022 Load Cabinet For Plug And Socket Normal Operation Life Test 0


IEC 60884-1 2022 Load Cabinet For Plug And Socket Normal Operation Life Test 1

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.