Model Number
SN2117F
Applied Standard:
IEC60669
Applied Clause:
18.3
Output Channel:
1 Channel
Load Power Capacity:
7.5KVA
Maximum Output Current:
20A
Maximum Output Voltage:
300V
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Standard Exporting Plywood Case
Delivery Time:
30 Days
Payment Terms:
L/C, T/T
Supply Ability:
20 Sets Per Month
High Light:

Filament Lamp Load Cabinet

,

Halogen Lamp Load Cabinet

,

IEC 60669 Lamp Load Cabinet

Product Description

 

IEC 60669 Clause 18.3 The Halogen and Filament Lamp Load Cabinet Max. 20A

 

Product Information:

This halogen lamp load cabinet meets the requirements of IEC60669 Clause 18.3, UL1054, UL943, etc.
This device is used for household and similar purpose fixed electrical appliance switch, plug and socket, coupler for on-off ability, breaking capacity and normal operation life test. The purpose is to assess whether the accessory can withstand the current surge and electrical fatigue damage that occur in normal use, as well as whether there is contact adhesion or long-term disconnection, and to check whether it has excessive wear and other harmful consequences.

 

Technical Parameters:

Applied standard IEC60669
Applied clause 18.3
Power supply Single-phase with ground cable: AC220±10%/50Hz
Digital display voltmeter Measuring range 0~300V, precision±0.5%±2d
Digital display ammeter Measuring range 0~40A, precision±0.5%±2d.
Digital display wattmeter Measuring range 0~9KW, precision±0.5%±2d

Loading method

Built-in 3 groups of multiple 200W halogen lamps combination, cyclically energized.
Output channel 1 channel.
Load power capacity 7.5KVA
Maximum output current 20A,when current exceeds 22A, the machine will cut off load outputting automatically
Maximum output voltage 300V, when exceeds 305V the machine will cut load outputting automatically.
Lamp combination The power of each lamp is 200W, 1/2/3/4/10/10 lamps can be combined.
Counter 0~999999 times , can be preset.
Long adhesive protection function Upper limited time 0~99S can be set.
Use environment Usage ambient temperature:5~40℃, relative humidity:(20~90)%RH, ambient environment air pressure:80~106kpa, no severe vibration, no vibration, no electromagnetic interference, no dust, no explosive, np corrosive gas, with good heat dissipation environment.
 
IEC 60669 Clause 18.3 The Halogen and Filament  Lamp Load Cabinet Max. 20A 0
products
PRODUCTS DETAILS
IEC 60669 Clause 18.3 The Halogen and Filament Lamp Load Cabinet Max. 20A
MOQ: 1
Price: Negotiable
Standard Packaging: Standard Exporting Plywood Case
Delivery Period: 30 Days
Payment Method: L/C, T/T
Supply Capacity: 20 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2117F
Applied Standard:
IEC60669
Applied Clause:
18.3
Output Channel:
1 Channel
Load Power Capacity:
7.5KVA
Maximum Output Current:
20A
Maximum Output Voltage:
300V
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Standard Exporting Plywood Case
Delivery Time:
30 Days
Payment Terms:
L/C, T/T
Supply Ability:
20 Sets Per Month
High Light

Filament Lamp Load Cabinet

,

Halogen Lamp Load Cabinet

,

IEC 60669 Lamp Load Cabinet

Product Description

 

IEC 60669 Clause 18.3 The Halogen and Filament Lamp Load Cabinet Max. 20A

 

Product Information:

This halogen lamp load cabinet meets the requirements of IEC60669 Clause 18.3, UL1054, UL943, etc.
This device is used for household and similar purpose fixed electrical appliance switch, plug and socket, coupler for on-off ability, breaking capacity and normal operation life test. The purpose is to assess whether the accessory can withstand the current surge and electrical fatigue damage that occur in normal use, as well as whether there is contact adhesion or long-term disconnection, and to check whether it has excessive wear and other harmful consequences.

 

Technical Parameters:

Applied standard IEC60669
Applied clause 18.3
Power supply Single-phase with ground cable: AC220±10%/50Hz
Digital display voltmeter Measuring range 0~300V, precision±0.5%±2d
Digital display ammeter Measuring range 0~40A, precision±0.5%±2d.
Digital display wattmeter Measuring range 0~9KW, precision±0.5%±2d

Loading method

Built-in 3 groups of multiple 200W halogen lamps combination, cyclically energized.
Output channel 1 channel.
Load power capacity 7.5KVA
Maximum output current 20A,when current exceeds 22A, the machine will cut off load outputting automatically
Maximum output voltage 300V, when exceeds 305V the machine will cut load outputting automatically.
Lamp combination The power of each lamp is 200W, 1/2/3/4/10/10 lamps can be combined.
Counter 0~999999 times , can be preset.
Long adhesive protection function Upper limited time 0~99S can be set.
Use environment Usage ambient temperature:5~40℃, relative humidity:(20~90)%RH, ambient environment air pressure:80~106kpa, no severe vibration, no vibration, no electromagnetic interference, no dust, no explosive, np corrosive gas, with good heat dissipation environment.
 