| MOQ: | 1 |
| Price: | Customized |
| Standard Packaging: | Plywood Case |
| Delivery Period: | 30 Days |
| Payment Method: | T/T |
| Supply Capacity: | 20 Sets Per Month |
![]()
| Test station | Single workstation, independent output |
| Electrical control method | Touchscreen + button control, instrument display |
| Digital voltage value | Measuring range 0-300V, accuracy class 0.5 |
| Digital power value | Measuring range 0-9KW, accuracy class 0.5 |
| Output voltage | 0-280V adjustable, ensure test voltage 250V~ |
| Preset switch rated voltage | Each circuit is 250V~, with four rated current options: 10A, 13A, 16A, and 20A |
| Working parameter settings | All parameters are set according to 250V~, including W, Ipeak, I²t, and the inrush current waveform |
| Usage environment | Power supply: AC220±5%/50Hz, 10KVA Operating environment: Atmospheric pressure 80~106kpa; ambient temperature 5~40°C; relative humidity (20~80)%RH, free from severe vibration, electromagnetic interference, dust, corrosive gases, and with good heat dissipation |
| Equipment structure and features | The load cabinet adopts an integrated steel structure frame and Toyota white paneling. The control panel is located on the top front. It includes a power switch, product test voltage and power display all integrated into a 10-inch touchscreen, an alarm, and internal resistor and capacitor load combinations, AC contactors, and relays. There are terminals at the bottom of the housing, which are connected to the product inside the testing machine via wires, and output current and provide load during the testing process. Equipment dimensions: approx. 800×800×1800 (mm) W×D×H; Equipment weight: 180kg |
| Calibration function | Each set of equipment is provided with a closing control device (select "Calibration" function on the touch screen). In this mode, the circuit is always turned on at a 90-degree azimuth angle. This function can be used for initial equipment calibration and metering verification. (The metering method involves exporting the current waveform using an external oscilloscope, and then calculating the I²t value. The oscilloscope is not provided.) |
| Protection function | Features include continuous interruption/continuous operation, with a preset protection time of 1-99 seconds. The system will shut down and alarm during protection. |
| MOQ: | 1 |
| Price: | Customized |
| Standard Packaging: | Plywood Case |
| Delivery Period: | 30 Days |
| Payment Method: | T/T |
| Supply Capacity: | 20 Sets Per Month |
![]()
| Test station | Single workstation, independent output |
| Electrical control method | Touchscreen + button control, instrument display |
| Digital voltage value | Measuring range 0-300V, accuracy class 0.5 |
| Digital power value | Measuring range 0-9KW, accuracy class 0.5 |
| Output voltage | 0-280V adjustable, ensure test voltage 250V~ |
| Preset switch rated voltage | Each circuit is 250V~, with four rated current options: 10A, 13A, 16A, and 20A |
| Working parameter settings | All parameters are set according to 250V~, including W, Ipeak, I²t, and the inrush current waveform |
| Usage environment | Power supply: AC220±5%/50Hz, 10KVA Operating environment: Atmospheric pressure 80~106kpa; ambient temperature 5~40°C; relative humidity (20~80)%RH, free from severe vibration, electromagnetic interference, dust, corrosive gases, and with good heat dissipation |
| Equipment structure and features | The load cabinet adopts an integrated steel structure frame and Toyota white paneling. The control panel is located on the top front. It includes a power switch, product test voltage and power display all integrated into a 10-inch touchscreen, an alarm, and internal resistor and capacitor load combinations, AC contactors, and relays. There are terminals at the bottom of the housing, which are connected to the product inside the testing machine via wires, and output current and provide load during the testing process. Equipment dimensions: approx. 800×800×1800 (mm) W×D×H; Equipment weight: 180kg |
| Calibration function | Each set of equipment is provided with a closing control device (select "Calibration" function on the touch screen). In this mode, the circuit is always turned on at a 90-degree azimuth angle. This function can be used for initial equipment calibration and metering verification. (The metering method involves exporting the current waveform using an external oscilloscope, and then calculating the I²t value. The oscilloscope is not provided.) |
| Protection function | Features include continuous interruption/continuous operation, with a preset protection time of 1-99 seconds. The system will shut down and alarm during protection. |