logo

Medical Material Tester ANSI/AAMI-EC53 2013/(R)2020 Flex Life Of Trunk Cable And Patient Leadwire Flex Relief

Basic Properties
Place of Origin: China
Brand Name: Sinuo
Certification: Calibration Certificate (Cost Additional)
Model Number: SN1112M
Trading Properties
Minimum Order Quantity: 1
Price: Customized
Payment Terms: T/T
Supply Ability: 10 sets per month
Specifications
Input power: AC220V 50HZ Control method: PLC Control
Drive mode: Servo Motor Drive Clamping method: Mechanical Clamping
Test station: 1 Station Flexing angle: 0-360°
Flexing rate: 0-60 Times/m Flexing times: 0~999999 Times
High Light:

Leadwire Flex Relief Medical Material Tester

,

:ANSI/AAMI-EC53 Medical Material Tester

Product Description

 

ANSI/AAMI-EC53: 2013/(R)2020 Flex Life Of Trunk Cable And Patient Leadwire Flex Relief

 

Standard & Clauses: 

 

AAMI-EC53-1998

ANSI/AAMI-EC53:2013/(R)2020 “ECG trunk cables and patient leadwires”

 

Specimen Range, Application, Principle, Structure and Use Environment:

 

Samples and Restrictions: EGA trunk cables and patient leadwires

Application: Used to test the bending resistance of EGA trunk cables and patient leadwires when the power cord enters the appliance. To verify its reliable performance.

Principle: Use a motor to drive the fixture to flex the sample. Apply current to the soft wire to make the sample flex left and right at a certain speed and angle of ±90°. And clamp the weight at a position 6 inches away from the lead outlet end of the sample. The test will automatically stop when the equipment reaches the test times or the soft wire is short-circuited.

Equipment structure and schematic diagram: 

The equipment is driven by a servo motor, and the fixture is installed in the center. And the eccentricity is adjustable. When clamping the sample, the flexing axis and the point where the cord enters the appliance can coincide as much as possible. This results in minimal lateral displacement of the cord and load.

Equipment dimensions: approximately: 800×800×1300 (mm) W×H×D, equipment weight: 130kg

 

Medical Material Tester ANSI/AAMI-EC53 2013/(R)2020 Flex Life Of Trunk Cable And Patient Leadwire Flex ReliefMedical Material Tester ANSI/AAMI-EC53 2013/(R)2020 Flex Life Of Trunk Cable And Patient Leadwire Flex Relief

 

Technical Parameters:

 

Test station Single
Electrical control method PLC and 7-inch touch screen
Drive mode Servo motor drive
Sample clamping method Mechanical clamping, the position of clamping point is adjustable
Flexing angle 0-360° adjustable arbitrarily (can be preset ±30°, ±45°, ±60°, ±90°)
Flexing rate 0-60 times/min, variable frequency speed regulation
Flexing times

0~999999 Can be preset and set according to standard table 1 requirements

Medical Material Tester ANSI/AAMI-EC53 2013/(R)2020 Flex Life Of Trunk Cable And Patient Leadwire Flex Relief

Load weight

1. 0.23kg (±5%), 1 piece (weight tray).

2. 0.1kg, 10 pieces, (add weight, stack weight). Achieve standard 0.0072*π*d² (±5%)

Test judgment

1. Short circuit judgment

2. Disconnection judgment

 

 

Medical Material Tester ANSI/AAMI-EC53 2013/(R)2020 Flex Life Of Trunk Cable And Patient Leadwire Flex Relief

 

Medical Material Tester ANSI/AAMI-EC53 2013/(R)2020 Flex Life Of Trunk Cable And Patient Leadwire Flex Relief

 

Medical Material Tester ANSI/AAMI-EC53 2013/(R)2020 Flex Life Of Trunk Cable And Patient Leadwire Flex Relief