logo
Products
PRODUCTS DETAILS
Home > Products >
IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test

IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2502
Power Consumption:
Maximum 1500W
Voltage Output:
AC Three-phase 415V±10%
Current Output:
AC 5~2000mA
Timing Accuracy:
5ms, Resolution 1ms
Type A Phase Selection:
0°, 90°, 135°
Type A Polarity Selection:
Positive, Negative
A/AC Type:
Switchable
Display Accuracy:
Class 1
Highlight:

IEC 61008-1 Residual Current Tester

,

Type A Polarity RCD Tester

,

5ms Timing Residual Current Tester

Product Description
Product Overview

This test equipment conforms to the standard requirements of IEC 61009-1:2012, IEC 60898-1:2015, IEC 61008-1:2010, and related specifications. It is specifically designed for the automatic verification of the operating characteristics of miniature residual current circuit breakers.

The instrument is built on an ARM-7 high-speed processor and is equipped with a high-speed true RMS A/D converter, a DSS sine wave generator with mains tracking, and a power amplifier. It automatically outputs current and can perform tests such as operating current and operating time, making it an ideal device for verifying molded case residual current circuit breakers.

IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test

Key Features
  • 24-bit high-speed, high-precision true RMS AD conversion for accurate sampling of operating current and voltage
  • High-speed processor for precise sampling of action time
  • Supports the standard Modbus-RTU communication protocol
  • Quick selection of operating current for conventional products, with separate setting for unconventional products
  • 32-bit embedded processor for high-speed processing of large volumes of communication data
  • RS232/485 full-rate asynchronous serial communication interface, with a maximum baud rate of 115200 bps
  • Isolation protection for input and output signals ensures safe operation
  • Software and hardware watchdog (WDT) design for system stability
  • Configuration parameters are stored in flash memory, retained permanently and not lost when power is off
  • Anti-jamming design in both software and hardware adapts to harsh electromagnetic environments
  • IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test
Technical Parameters
Operating Power Supply AC three-phase 415V ±10%
Operating Power Consumption Maximum 1500W
Human-Machine Interface 4.3-inch touchscreen
Current and Voltage Display Accuracy Class 1; current resolution 0.1mA; voltage resolution 0.1V
Current Output Range AC: 5~2000mA
Voltage Output AC three-phase 415V ±10%
Timing Accuracy 5ms; resolution 1ms
Type A Phase Selection 0 degrees (2000mA), 90 degrees (2000mA), 135 degrees (30mA)
Type A Polarity Selection Positive, Negative, Positive + DC 6mA, Negative + DC 6mA
Operating Environment -20~70℃, 90%RH (non-condensing)
Storage Environment -30~75℃, 90%RH (non-condensing)
Dimensions 49 × 37 × 34 mm (L × W × H)
Weight Approximately 20kg
Computer Software Included for setting up, starting, and monitoring tests, enabling customers to save and print test reports
Working Principle

The instrument supplies mains voltage directly to the test sample's voltage input terminal after switching and adjusting the range. Simultaneously, the signal board collects the mains frequency and phase synchronization to generate a sinusoidal signal, which is then amplified to obtain the simulated leakage current of the test sample and applied to it.

The main control board collects the test sample's input voltage, output voltage, and leakage current, then analyzes and calculates data such as the operating current and operating time through software. The principal diagram is shown below:

Principal diagram of the residual current operating characteristic tester showing signal board, main control board, power amplifier, and test sample connections
Principal diagram of the residual current operating characteristic tester.
Operating Instructions
  • [A/AC Type]:Switch between A and AC types.
  • [Current Polarity]:Adjust the current polarity after entering the A-type operation interface.
  • [Angle]:Adjust the angle (0°, 90°, 135°) after entering the A-type interface.
  • [DC6mA]:Adjust ±6mA in the A-type interface.
  • [Function Keys]:After entering the interface, adjust the starting ratio (starting current percentage), rise rate (test speed), manual/automatic switching, and address setting. Click the [knob] to select an item and rotate the [knob] to adjust it.
  • [Calibration]:After entering, manually adjust the output current and compare it with the standard meter.
  • [ABC Phases]:During 4P product testing, click to select which phase the leakage current is applied to (default is phase A).
  • Time Multiplier:Used during time testing. The output current equals the current range multiplied by the [Time Multiplier] (default is 1; clicking again changes the multiplier).
  • Current Range ±:Set on the touchscreen interface.
  • Voltage Range ±:Set on the touchscreen interface.
  • Current:Leakage current (gradual change) test interface.
  • Time:Press once for the leakage time (sudden increase) test; press twice to enter [Closed Test], which tests closing and opening.
  • Button:Test product button.
  • Test:Start button in manual mode.
  • IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test
Products
PRODUCTS DETAILS
IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2502
Power Consumption:
Maximum 1500W
Voltage Output:
AC Three-phase 415V±10%
Current Output:
AC 5~2000mA
Timing Accuracy:
5ms, Resolution 1ms
Type A Phase Selection:
0°, 90°, 135°
Type A Polarity Selection:
Positive, Negative
A/AC Type:
Switchable
Display Accuracy:
Class 1
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
10 Sets Per Month
Highlight

IEC 61008-1 Residual Current Tester

,

Type A Polarity RCD Tester

,

5ms Timing Residual Current Tester

Product Description
Product Overview

This test equipment conforms to the standard requirements of IEC 61009-1:2012, IEC 60898-1:2015, IEC 61008-1:2010, and related specifications. It is specifically designed for the automatic verification of the operating characteristics of miniature residual current circuit breakers.

The instrument is built on an ARM-7 high-speed processor and is equipped with a high-speed true RMS A/D converter, a DSS sine wave generator with mains tracking, and a power amplifier. It automatically outputs current and can perform tests such as operating current and operating time, making it an ideal device for verifying molded case residual current circuit breakers.

IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test

Key Features
  • 24-bit high-speed, high-precision true RMS AD conversion for accurate sampling of operating current and voltage
  • High-speed processor for precise sampling of action time
  • Supports the standard Modbus-RTU communication protocol
  • Quick selection of operating current for conventional products, with separate setting for unconventional products
  • 32-bit embedded processor for high-speed processing of large volumes of communication data
  • RS232/485 full-rate asynchronous serial communication interface, with a maximum baud rate of 115200 bps
  • Isolation protection for input and output signals ensures safe operation
  • Software and hardware watchdog (WDT) design for system stability
  • Configuration parameters are stored in flash memory, retained permanently and not lost when power is off
  • Anti-jamming design in both software and hardware adapts to harsh electromagnetic environments
  • IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test
Technical Parameters
Operating Power Supply AC three-phase 415V ±10%
Operating Power Consumption Maximum 1500W
Human-Machine Interface 4.3-inch touchscreen
Current and Voltage Display Accuracy Class 1; current resolution 0.1mA; voltage resolution 0.1V
Current Output Range AC: 5~2000mA
Voltage Output AC three-phase 415V ±10%
Timing Accuracy 5ms; resolution 1ms
Type A Phase Selection 0 degrees (2000mA), 90 degrees (2000mA), 135 degrees (30mA)
Type A Polarity Selection Positive, Negative, Positive + DC 6mA, Negative + DC 6mA
Operating Environment -20~70℃, 90%RH (non-condensing)
Storage Environment -30~75℃, 90%RH (non-condensing)
Dimensions 49 × 37 × 34 mm (L × W × H)
Weight Approximately 20kg
Computer Software Included for setting up, starting, and monitoring tests, enabling customers to save and print test reports
Working Principle

The instrument supplies mains voltage directly to the test sample's voltage input terminal after switching and adjusting the range. Simultaneously, the signal board collects the mains frequency and phase synchronization to generate a sinusoidal signal, which is then amplified to obtain the simulated leakage current of the test sample and applied to it.

The main control board collects the test sample's input voltage, output voltage, and leakage current, then analyzes and calculates data such as the operating current and operating time through software. The principal diagram is shown below:

Principal diagram of the residual current operating characteristic tester showing signal board, main control board, power amplifier, and test sample connections
Principal diagram of the residual current operating characteristic tester.
Operating Instructions
  • [A/AC Type]:Switch between A and AC types.
  • [Current Polarity]:Adjust the current polarity after entering the A-type operation interface.
  • [Angle]:Adjust the angle (0°, 90°, 135°) after entering the A-type interface.
  • [DC6mA]:Adjust ±6mA in the A-type interface.
  • [Function Keys]:After entering the interface, adjust the starting ratio (starting current percentage), rise rate (test speed), manual/automatic switching, and address setting. Click the [knob] to select an item and rotate the [knob] to adjust it.
  • [Calibration]:After entering, manually adjust the output current and compare it with the standard meter.
  • [ABC Phases]:During 4P product testing, click to select which phase the leakage current is applied to (default is phase A).
  • Time Multiplier:Used during time testing. The output current equals the current range multiplied by the [Time Multiplier] (default is 1; clicking again changes the multiplier).
  • Current Range ±:Set on the touchscreen interface.
  • Voltage Range ±:Set on the touchscreen interface.
  • Current:Leakage current (gradual change) test interface.
  • Time:Press once for the leakage time (sudden increase) test; press twice to enter [Closed Test], which tests closing and opening.
  • Button:Test product button.
  • Test:Start button in manual mode.
  • IEC 61008-1 Residual Current Operating Characteristic Tester For RCD Circuit Breaker Test
sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2026 Sinuo Testing Equipment Co. , Limited . All Rights Reserved.