IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave

IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 5 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Model Number
SN2501
Applied Standard:
IEC 60898-1
Applied Clause:
Clause 9.10
Test Station:
Delay: 1 Station; Instant: 1 Station
Test Items:
Tripping Characteristics
Output AC Current:
3~180A
Output AC Voltage:
0~5V
Miniature Circuit Breaker:
3~63A
Current Output Waveform:
Sine Wave
Highlight:

IEC 60898-1 Clause 9.10 MCB Testing Machine

,

3~63A Miniature Circuit Breaker Tester

,

Sine Wave Current Output MCB Testing Machine

Product Description
Product Overview

This test equipment is designed and manufactured in accordance with the standard requirements of IEC 60898-1 clause 9.10, IEC 60947-1 clause 7.2.1, and other relevant standards.

It is built to verify that circuit breakers comply with the applicable requirements by applying 1.13 times, 1.45 times, and 2.55 times the rated current, and checking whether the breaker trips within the specified time. The equipment can also test the instantaneous tripping characteristics of the circuit breaker by applying 3 to 10 times the rated current to determine whether it trips within the required time.

It is suitable for online testing of molded case circuit breakers and miniature circuit breakers before leaving the factory, and is essential equipment for electrical performance testing in circuit breaker manufacturing.

IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave

Technical Parameters
Applied Standard IEC 60898-1
Clause 9.10
Control Method 10-inch color touch screen operation
Test Items Small instantaneous tripping characteristics, time, delayed tripping characteristics
Test Station Delay: one station; Instant: one station; meets 1–4P circuit breaker requirements
Delay Trip Parameters
Output AC Current 3–180 A
Output AC Voltage 0–5 V
Output Current Channel 1 channel; multi-P circuit breaker contacts are connected in series to test several switches
Test Miniature Circuit Breaker Products 3–63
Current Output Waveform Sine wave (correction equipment current waveform distortion not more than 5%, system error not more than 3%)
Current Control Method Automatic adjustment; current is set on the touch screen
Current Accuracy Level 0.5
Voltage Accuracy Level 0.5
Transformer Ratio 200/5 A
Test Time 1–999999 s
Current After 1.13 times the current is applied, it quickly and automatically rises to 1.45 times the current within 5 seconds
Fixture Terminal method; Delay: one station; Instantaneous: one station
Instantaneous Trip Test
Fixture Terminal method; Delay: one station; Instantaneous: one station
Output Current AC 30 A–1500 A
Output Current Channels 1 channel
Current Accuracy 0.5 level
Resolution 1 A
Instantaneous Test Time ≤ 0.2 s
Action Time Upper Limit Setting 1–200 ms
Action Time Lower Limit Setting 1–200 ms
Test Station 1 station
Timing Time 1–9999 ms
Protective Function Short circuit protection, overload protection, leakage protection
Temperature Rise Test

Under normal working conditions, when the circuit breaker is tested according to the specified conditions, it should not be damaged in a way that affects its function or safety of use.

Temperature Measurement Channel 8 channels; temperature resolution: 0.1 °C
Thermocouple T type
Temperature Curve Touch screen display with temperature data logging table
Temperature Measurement Range 0–200 °C
Configuration Wires for temperature rise test: 1, 1.5, 2, 2.5, 4, 6 and 10 mm², each specification 1 meter long, 5 pcs per specification; 16, 25, 50 and 70 mm², each specification 2 meters long, 5 pcs per specification
Equipment Characteristics

The equipment chamber is welded with high-quality steel, and the plate is sprayed and sealed. The surface is treated with anti-static, anti-rust, and anti-corrosion spraying.

The upper part of the equipment is equipped with a panel, a power switch, and a variety of wire ends for the delay tripping test. The equipment features a rational design and offers the advantages of convenience, simple operation, reliable performance, and an attractive appearance.

IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave

Test Principle

This test equipment adopts the principle of low-voltage, high-current output. It uses the large current inside the machine to isolate the output current of the transformer. The current magnitude is set via the touch screen, and the constant current source adjusts the output current of the transformer, providing automatic current stabilization.

The test time is set through the touch screen display, and the measured trip time is compared to judge the quality of the circuit breaker.

IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave

Products
PRODUCTS DETAILS
IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 5 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Model Number
SN2501
Applied Standard:
IEC 60898-1
Applied Clause:
Clause 9.10
Test Station:
Delay: 1 Station; Instant: 1 Station
Test Items:
Tripping Characteristics
Output AC Current:
3~180A
Output AC Voltage:
0~5V
Miniature Circuit Breaker:
3~63A
Current Output Waveform:
Sine Wave
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
5 Sets Per Month
Highlight

IEC 60898-1 Clause 9.10 MCB Testing Machine

,

3~63A Miniature Circuit Breaker Tester

,

Sine Wave Current Output MCB Testing Machine

Product Description
Product Overview

This test equipment is designed and manufactured in accordance with the standard requirements of IEC 60898-1 clause 9.10, IEC 60947-1 clause 7.2.1, and other relevant standards.

It is built to verify that circuit breakers comply with the applicable requirements by applying 1.13 times, 1.45 times, and 2.55 times the rated current, and checking whether the breaker trips within the specified time. The equipment can also test the instantaneous tripping characteristics of the circuit breaker by applying 3 to 10 times the rated current to determine whether it trips within the required time.

It is suitable for online testing of molded case circuit breakers and miniature circuit breakers before leaving the factory, and is essential equipment for electrical performance testing in circuit breaker manufacturing.

IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave

Technical Parameters
Applied Standard IEC 60898-1
Clause 9.10
Control Method 10-inch color touch screen operation
Test Items Small instantaneous tripping characteristics, time, delayed tripping characteristics
Test Station Delay: one station; Instant: one station; meets 1–4P circuit breaker requirements
Delay Trip Parameters
Output AC Current 3–180 A
Output AC Voltage 0–5 V
Output Current Channel 1 channel; multi-P circuit breaker contacts are connected in series to test several switches
Test Miniature Circuit Breaker Products 3–63
Current Output Waveform Sine wave (correction equipment current waveform distortion not more than 5%, system error not more than 3%)
Current Control Method Automatic adjustment; current is set on the touch screen
Current Accuracy Level 0.5
Voltage Accuracy Level 0.5
Transformer Ratio 200/5 A
Test Time 1–999999 s
Current After 1.13 times the current is applied, it quickly and automatically rises to 1.45 times the current within 5 seconds
Fixture Terminal method; Delay: one station; Instantaneous: one station
Instantaneous Trip Test
Fixture Terminal method; Delay: one station; Instantaneous: one station
Output Current AC 30 A–1500 A
Output Current Channels 1 channel
Current Accuracy 0.5 level
Resolution 1 A
Instantaneous Test Time ≤ 0.2 s
Action Time Upper Limit Setting 1–200 ms
Action Time Lower Limit Setting 1–200 ms
Test Station 1 station
Timing Time 1–9999 ms
Protective Function Short circuit protection, overload protection, leakage protection
Temperature Rise Test

Under normal working conditions, when the circuit breaker is tested according to the specified conditions, it should not be damaged in a way that affects its function or safety of use.

Temperature Measurement Channel 8 channels; temperature resolution: 0.1 °C
Thermocouple T type
Temperature Curve Touch screen display with temperature data logging table
Temperature Measurement Range 0–200 °C
Configuration Wires for temperature rise test: 1, 1.5, 2, 2.5, 4, 6 and 10 mm², each specification 1 meter long, 5 pcs per specification; 16, 25, 50 and 70 mm², each specification 2 meters long, 5 pcs per specification
Equipment Characteristics

The equipment chamber is welded with high-quality steel, and the plate is sprayed and sealed. The surface is treated with anti-static, anti-rust, and anti-corrosion spraying.

The upper part of the equipment is equipped with a panel, a power switch, and a variety of wire ends for the delay tripping test. The equipment features a rational design and offers the advantages of convenience, simple operation, reliable performance, and an attractive appearance.

IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave

Test Principle

This test equipment adopts the principle of low-voltage, high-current output. It uses the large current inside the machine to isolate the output current of the transformer. The current magnitude is set via the touch screen, and the constant current source adjusts the output current of the transformer, providing automatic current stabilization.

The test time is set through the touch screen display, and the measured trip time is compared to judge the quality of the circuit breaker.

IEC 60898-1 Clause 9.10 MCB Testing Machine for 3~63A Miniature Circuit Breaker with Sine Wave