logo

IEC 60065 Hazardous Live Parts Probe Verify The Protection Against Access to hazardous parts

Basic Properties
Place of Origin: China
Brand Name: Sinuo
Certification: Calibration Certificate (Cost Additional)
Model Number: SN2210-75
Trading Properties
Minimum Order Quantity: 1
Price: Customized
Payment Terms: T/T
Supply Ability: 100 sets per month
Specifications
Applied Standard: IEC 60065 Applied Clause: Clause 9.1.3
Probe diameter: Φ4 Mm Handle length: 100mm
Baffle diameter: Ф35±0.2 Mm Probe length: 100±0.2 Mm
Probe Material: Stainless Steel Handle Material: Nylon
High Light:

IEC 60065 hazardous parts probe

,

hazardous live parts tester

,

switch life protection tester

Product Description

 

IEC 60065 Hazardous Live Parts Probe Verify The Protection Against Access to hazardous parts

 

Product information:

 

Standard:IEC60065:2014 clause 9.1.3, EN61010-1, UL3101-1 and CSA 1010-1, and etc.

Application:This testing probe is used to verify the protection against access to hazardous parts through top openings.

Test sample:Audio, video and similar electronic apparatus.

Feature:It can be used for anti-electric shock test when it is equipped with amphenol connector or used for enclosure protection test when open threaded hole of M6 at the end of the handle (connected with pull and push dynamometer).

 

 

Technical Parameters:

 

Probe diameter Ф4+0.05 0 mm
Sphere baffle SФ35±0.2 mm
Handle diameter Ф10 mm
Probe length 100±0.2 mm
Handle length 100mm
Standards IEC60065:2014 clause 9.1.1.3, EN61010-1, UL3101-1 and CSA 1010-1, etc.
 

Sinuohave a full range of test probes according to different standards, and also can offer customized service.

IEC 60065 Hazardous Live Parts Probe Verify The Protection Against Access to hazardous parts

Test procedures and operation

 

Please refer to the relevant standards.

Take IEC 60950 clause 2.1.1.1 as an example:

This test probe is applied to openings, without appreciable force, in every possible position, except that floor-standing equipment having a mass exceeding 40 kg is not tilted.

The test probe doesn’t have built-in force, if specific applied force required, the test probe should work together with a force gauge. At the end of our probe handle, there is a M6 thread hole to match the force gauge. Showing as following reference picture:

IEC 60065 Hazardous Live Parts Probe Verify The Protection Against Access to hazardous parts

 

IEC 60065 Hazardous Live Parts Probe Verify The Protection Against Access to hazardous parts

IEC 60065 Hazardous Live Parts Probe Verify The Protection Against Access to hazardous parts

Notice

1. Please do not damage the appliance shape (such as scratching, bending, etc.).

2. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.

3. Be careful of electric shock.