logo
products
PRODUCTS DETAILS
Home > Products >
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa

IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN8810C-1m3
Effective Size:
1000×1000×1000 W×D×H
External Space:
1600×2400×2000 W×D×H
Temperature Range:
20~70℃
Range Of Humidity:
30%R.H~98%R.H
Salt Mist:
1~2ml/h/80cm2
Spray Pressure:
70~170Kpa
Machine Power:
15KW
Maximum Current:
23A
Highlight:

170Kpa Compound Salt Corrosion Test Chamber

,

1M3 Compound Salt Corrosion Test Chamber

Product Description

 

IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa

 

1. Product information:

 

1.1 Corrosion of protected and unprotected metallic materials is influenced by many environmental factors, which mainly depend on the type of metallic material and the type of environment. It is impossible to design a laboratory accelerated corrosion test chamber that includes all environmental factors that affect corrosion resistance. Therefore, the laboratory test is designed by simulating the factors that play a major role in the corrosion of metallic materials. This equipment is designed to simulate and increase the effects of the environment on metallic materials exposed to an outdoor atmosphere that is contaminated with salt and can accelerate corrosion. The equipment includes a test method for cyclically exposing the sample to salt spray, dry, hot and humid environments. This equipment test is a comparative test, and the test results cannot predict the long-term results of the corrosion resistance of the same metal material used under this environmental condition. However, this method can still provide valuable information on the relative performance of materials exposed to salt pollution like the test conditions. Compared with traditional accelerated corrosion tests, such as neutral salt spray test (NSS), acetic acid salt spray test (AASS), and copper accelerated acetic acid salt spray test (CASS), the biggest advantage of this equipment test is that it can better Reproduces corrosion that occurs outdoors in salt-contaminated environments.

1.2 The equipment has temperature-humidity-heat alternating salt spray compound test chamber with temperature and humidity adjustment function is used to test various performance indicators and quality management of accessories under alternating compound conditions such as high temperature, humidity, dryness, and salt spray.

1.3 The equipment has an emergency braking function, and a brake switch is installed on the equipment. When an abnormal situation occurs, the equipment can be powered off through the control switch.

1.4 The equipment is equipped with corresponding system software, which can run stably on the provided operating system, and the software interface is in Chinese or English, the software includes temperature change test, humidity, precision calibration, and equipment self-test module.

1.5 The system software can record in real time, save automatically, and optimize data, and can draw temperature-time, humidity-time curves through software settings.

1.6 The system software is set with a safety protection parameter interface, and after the setting is completed, it will be given priority during the test process, thereby ensuring the safety of the test.

1.7 The system software can achieve the function of test data security protection, and the software has the function of administrator, which can limit the operation authority of general operators.

1.8 The system software has the function of post-data processing, which can support the import of multiple data files, support data filtering, and support arbitrary X-axis and Y-axis selection.

 

 

2. Volume, weight, dimensions and specifications:

 

2.1 Product Name Compound Salt Spray Test Chamber
2.2 Product model SN8810C-1m3
2.3 Nominal internal volume

1m³

Note: Does not include the volume of the top sloping roof

2.4 Effective size of inner box (mm)

1000×1000×1000 W×D×H

Note: The height of the top slope is 600mm

2.5 External space (mm) About 1600×2400×2000 W×D×H
2.6 Weight About 500kg
2.7 Bearing capacity About 80KG

 

 

3. Device power, current and power supply:

 

3.1 Total machine power 15KW
3.2 Maximum current 23A
3.3 Power supply conditions and power supply

AC380V three-phase four-wire system + protective grounding; the allowable fluctuation range of voltage is ±10%V.

The allowable frequency fluctuation range is 50±0.5HZ; TN-S power supply or TT power supply.

The grounding resistance of the protective ground wire is less than 4Ω.

The user is required to configure an air or power switch of corresponding capacity for the equipment at the installation site, and the switch must independently control the use of the equipment. When placing electrified samples in the chamber box, please use an external power supply for the sample power supply, and do not use the local power supply directly.

 

 

4. Equipment main technical parameters:

 

4.1 Temperature range of test chamber 20~70℃ continuously adjustable
4.2 Temperature range of saturation tank RT+5℃~70℃
4.3 Range of humidity 30%R.H~98%R.H (as shown in the figure)
4.4 Salt mist deposition amount

1~2ml/h/80cm2 (at least 16 hours of collection, take the average value)

Note: The monitoring point of the spray volume is located in the test area close to the surface of the sample

4.5 Spray pressure 70~170Kpa
4.6 Spray method Three modes of continuous spray, cycle spray and program spray can be adjusted by yourself
4.7 PH value of liquid medicine Neutral test 6.5~7.2 Acid test 3.0~3.3
4.8 Test conditions

A. Commonly used alternating salt spray test conditions: ambient temperature of 35°C, saturated barrel temperature of 47°C, spray test time of 5% salt water concentration from 1min to 999h can be set arbitrarily, and then in the damp heat test at a temperature of 40°C±2°C, relative humidity 93%RH±3%RH, the test time can be set arbitrarily from 1min to 999h; the cycle can be set arbitrarily from 1 to 999 times. Then, let it stand for 1min to 999h under standard environmental conditions with a temperature of 23°C±2°C and a relative humidity of 50%RH±5%RH, which can be set arbitrarily.

 

B. Dry and wet compound salt spray test conditions: at an ambient temperature of 35°C, a saturated barrel temperature of 47°C, and a spray test time of 5% salt water concentration from 1min to 999h, which can be set arbitrarily; dry under the condition that the relative humidity is equal to or lower than 30%RH For the test, the test time can be set arbitrarily from 1min to 999h; in the humid and hot environment with a relative humidity greater than 95%RH, the test time can be set arbitrarily from 1min to 999h; then return to the first step of the salt spray test; the cycle can be set arbitrarily from 1 to 999 times.

 

C. NSS salt spray test, AASS acetic acid salt spray test, CASS copper accelerated acetic acid salt spray test, damp heat test, drying test, standard large climate environment test conditions or other combined test conditions can be carried out independently.

4.9 Control accuracy

Temperature resolution: 0.1°C

Humidity resolution: 0.1%R.H

Temperature deviation: ±2.0℃

Humidity deviation: ≤+2-3%R.H when ≥75%RH,

humidity deviation: ≤±5%R.H when <75%RH

Temperature fluctuation: ±1℃

Humidity fluctuation: ±3%R.H

Note: The temperature uniformity and deviation are measured under the conditions of ambient temperature +25°C, relative humidity ≤85% RH, and no sample.

4.1 Heating rate of the test room RT→+60℃≤45 min
4.2 Heating rate of saturated tank RT→+65℃≤45 min
4.12 Specimen restrictions

This test chamber prohibits:

Testing or storage of samples of flammable, explosive and volatile substances

Testing or storage of samples of corrosive substances

Testing or storage of biological samples

Testing or storage of samples of strong electromagnetic emission sources

Testing and storage of radioactive material samples

Testing and storage of samples of highly toxic substances

Testing and storage of samples that may produce highly toxic substances during testing or storage

 
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa 0
 
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa 1
 
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa 2

products
PRODUCTS DETAILS
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN8810C-1m3
Effective Size:
1000×1000×1000 W×D×H
External Space:
1600×2400×2000 W×D×H
Temperature Range:
20~70℃
Range Of Humidity:
30%R.H~98%R.H
Salt Mist:
1~2ml/h/80cm2
Spray Pressure:
70~170Kpa
Machine Power:
15KW
Maximum Current:
23A
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
10 sets per month
Highlight

170Kpa Compound Salt Corrosion Test Chamber

,

1M3 Compound Salt Corrosion Test Chamber

Product Description

 

IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa

 

1. Product information:

 

1.1 Corrosion of protected and unprotected metallic materials is influenced by many environmental factors, which mainly depend on the type of metallic material and the type of environment. It is impossible to design a laboratory accelerated corrosion test chamber that includes all environmental factors that affect corrosion resistance. Therefore, the laboratory test is designed by simulating the factors that play a major role in the corrosion of metallic materials. This equipment is designed to simulate and increase the effects of the environment on metallic materials exposed to an outdoor atmosphere that is contaminated with salt and can accelerate corrosion. The equipment includes a test method for cyclically exposing the sample to salt spray, dry, hot and humid environments. This equipment test is a comparative test, and the test results cannot predict the long-term results of the corrosion resistance of the same metal material used under this environmental condition. However, this method can still provide valuable information on the relative performance of materials exposed to salt pollution like the test conditions. Compared with traditional accelerated corrosion tests, such as neutral salt spray test (NSS), acetic acid salt spray test (AASS), and copper accelerated acetic acid salt spray test (CASS), the biggest advantage of this equipment test is that it can better Reproduces corrosion that occurs outdoors in salt-contaminated environments.

1.2 The equipment has temperature-humidity-heat alternating salt spray compound test chamber with temperature and humidity adjustment function is used to test various performance indicators and quality management of accessories under alternating compound conditions such as high temperature, humidity, dryness, and salt spray.

1.3 The equipment has an emergency braking function, and a brake switch is installed on the equipment. When an abnormal situation occurs, the equipment can be powered off through the control switch.

1.4 The equipment is equipped with corresponding system software, which can run stably on the provided operating system, and the software interface is in Chinese or English, the software includes temperature change test, humidity, precision calibration, and equipment self-test module.

1.5 The system software can record in real time, save automatically, and optimize data, and can draw temperature-time, humidity-time curves through software settings.

1.6 The system software is set with a safety protection parameter interface, and after the setting is completed, it will be given priority during the test process, thereby ensuring the safety of the test.

1.7 The system software can achieve the function of test data security protection, and the software has the function of administrator, which can limit the operation authority of general operators.

1.8 The system software has the function of post-data processing, which can support the import of multiple data files, support data filtering, and support arbitrary X-axis and Y-axis selection.

 

 

2. Volume, weight, dimensions and specifications:

 

2.1 Product Name Compound Salt Spray Test Chamber
2.2 Product model SN8810C-1m3
2.3 Nominal internal volume

1m³

Note: Does not include the volume of the top sloping roof

2.4 Effective size of inner box (mm)

1000×1000×1000 W×D×H

Note: The height of the top slope is 600mm

2.5 External space (mm) About 1600×2400×2000 W×D×H
2.6 Weight About 500kg
2.7 Bearing capacity About 80KG

 

 

3. Device power, current and power supply:

 

3.1 Total machine power 15KW
3.2 Maximum current 23A
3.3 Power supply conditions and power supply

AC380V three-phase four-wire system + protective grounding; the allowable fluctuation range of voltage is ±10%V.

The allowable frequency fluctuation range is 50±0.5HZ; TN-S power supply or TT power supply.

The grounding resistance of the protective ground wire is less than 4Ω.

The user is required to configure an air or power switch of corresponding capacity for the equipment at the installation site, and the switch must independently control the use of the equipment. When placing electrified samples in the chamber box, please use an external power supply for the sample power supply, and do not use the local power supply directly.

 

 

4. Equipment main technical parameters:

 

4.1 Temperature range of test chamber 20~70℃ continuously adjustable
4.2 Temperature range of saturation tank RT+5℃~70℃
4.3 Range of humidity 30%R.H~98%R.H (as shown in the figure)
4.4 Salt mist deposition amount

1~2ml/h/80cm2 (at least 16 hours of collection, take the average value)

Note: The monitoring point of the spray volume is located in the test area close to the surface of the sample

4.5 Spray pressure 70~170Kpa
4.6 Spray method Three modes of continuous spray, cycle spray and program spray can be adjusted by yourself
4.7 PH value of liquid medicine Neutral test 6.5~7.2 Acid test 3.0~3.3
4.8 Test conditions

A. Commonly used alternating salt spray test conditions: ambient temperature of 35°C, saturated barrel temperature of 47°C, spray test time of 5% salt water concentration from 1min to 999h can be set arbitrarily, and then in the damp heat test at a temperature of 40°C±2°C, relative humidity 93%RH±3%RH, the test time can be set arbitrarily from 1min to 999h; the cycle can be set arbitrarily from 1 to 999 times. Then, let it stand for 1min to 999h under standard environmental conditions with a temperature of 23°C±2°C and a relative humidity of 50%RH±5%RH, which can be set arbitrarily.

 

B. Dry and wet compound salt spray test conditions: at an ambient temperature of 35°C, a saturated barrel temperature of 47°C, and a spray test time of 5% salt water concentration from 1min to 999h, which can be set arbitrarily; dry under the condition that the relative humidity is equal to or lower than 30%RH For the test, the test time can be set arbitrarily from 1min to 999h; in the humid and hot environment with a relative humidity greater than 95%RH, the test time can be set arbitrarily from 1min to 999h; then return to the first step of the salt spray test; the cycle can be set arbitrarily from 1 to 999 times.

 

C. NSS salt spray test, AASS acetic acid salt spray test, CASS copper accelerated acetic acid salt spray test, damp heat test, drying test, standard large climate environment test conditions or other combined test conditions can be carried out independently.

4.9 Control accuracy

Temperature resolution: 0.1°C

Humidity resolution: 0.1%R.H

Temperature deviation: ±2.0℃

Humidity deviation: ≤+2-3%R.H when ≥75%RH,

humidity deviation: ≤±5%R.H when <75%RH

Temperature fluctuation: ±1℃

Humidity fluctuation: ±3%R.H

Note: The temperature uniformity and deviation are measured under the conditions of ambient temperature +25°C, relative humidity ≤85% RH, and no sample.

4.1 Heating rate of the test room RT→+60℃≤45 min
4.2 Heating rate of saturated tank RT→+65℃≤45 min
4.12 Specimen restrictions

This test chamber prohibits:

Testing or storage of samples of flammable, explosive and volatile substances

Testing or storage of samples of corrosive substances

Testing or storage of biological samples

Testing or storage of samples of strong electromagnetic emission sources

Testing and storage of radioactive material samples

Testing and storage of samples of highly toxic substances

Testing and storage of samples that may produce highly toxic substances during testing or storage

 
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa 0
 
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa 1
 
IEC 60068-2-11 1M3 Compound Salt Corrosion Test Chamber Spray Pressure 70~170Kpa 2

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2025 Sinuo Testing Equipment Co. , Limited . All Rights Reserved.