Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2904
Applied Standard:
IEC 61386-21
Applied Clause:
Clause 10.4.102
Material:
Steel
Manufacturing Tolerance:
+0.05mm
Axial Dimension:
±0.2mm
Admissible Wear:
0.01mm
Highlight:

IEC 61386-21 Gauge

,

Minimum Inside Diameter Gauge

,

Conduit System Gauge

Product Description

 

IEC 61386-21 Figure 102 Gauge For Checking The Minimum Inside Diameter Of The Conduit System
 
 
Product information:
 
This gauge is the minimum inner diameter gauge for metal conduits and other materials after bending tests. When the sample is tested in IEC61386-21, clause 10.4.101 (one end of the sample is vertical and the other end is at a 45° angle to the vertical line), this gauge should pass through the sample with no initial velocity. Comply with the requirements of Clause 6.7.2 and Figure 12 of JG3050-1998 "Insulated Electrical Bushings and Accessories for Buildings", "GB 20041.21-2008 Conduit Systems for Cable Management - Special Requirements for Rigid Conduit Systems", GB/T14823.2 "Conduits for Electrical Installation" Special requirements - Rigid insulating material flat conduit", ZBG33008 "Polyvinyl chloride plastic corrugated wire conduit" and IEC61386-21 Section 10.4.101 and Figure 102 and IEC61386-22 Section 10.4.102 and Figure 102 and other requirements.
 

IEC 61386-21 Figure 102 Gauge For Checking Minimum Inside Diameter Of Conduit System 0
 
Technical parameters:
 
1. Material: steel, surface hard chromium plated
2. Gauge selection table (unit: mm)
 

No. Gauge D+0.05 0 Sample nominal diameter Minimum inner diameter of sample Remark
Minimum inner diameter gauge of metal casing after bending: IEC61386-21
1 10.2 16 12.75  
2 13.1 20 16.38  
3 16.8 25 21.0  
Minimum inner diameter gauge of non-metallic casing after bending: IEC61386-22
1 8.6 16 10.75  
2 11.3 20 14.13  
3 14.6 25 18.25  
4 19.4 32 24.25  
5 25.0 40 31.25  
6 31.7 50 39.63  
7 41 63 51.25  
Note: Tolerance of other dimensions not specified is ±0.2mm, surface wear shall not exceed 0.01mm

 
3. There are 10 gauges in total, including 3 minimum inner diameter gauges for metal casing bending and 7 minimum inner diameter gauges for non-metal casing bending.
 

IEC 61386-21 Figure 102 Gauge For Checking Minimum Inside Diameter Of Conduit System 1

 

products
PRODUCTS DETAILS
IEC 61386-21 Figure 102 Gauge For Checking Minimum Inside Diameter Of Conduit System
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 days
Payment Method: T/T
Supply Capacity: 20 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2904
Applied Standard:
IEC 61386-21
Applied Clause:
Clause 10.4.102
Material:
Steel
Manufacturing Tolerance:
+0.05mm
Axial Dimension:
±0.2mm
Admissible Wear:
0.01mm
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 days
Payment Terms:
T/T
Supply Ability:
20 Sets Per Month
Highlight

IEC 61386-21 Gauge

,

Minimum Inside Diameter Gauge

,

Conduit System Gauge

Product Description

 

IEC 61386-21 Figure 102 Gauge For Checking The Minimum Inside Diameter Of The Conduit System
 
 
Product information:
 
This gauge is the minimum inner diameter gauge for metal conduits and other materials after bending tests. When the sample is tested in IEC61386-21, clause 10.4.101 (one end of the sample is vertical and the other end is at a 45° angle to the vertical line), this gauge should pass through the sample with no initial velocity. Comply with the requirements of Clause 6.7.2 and Figure 12 of JG3050-1998 "Insulated Electrical Bushings and Accessories for Buildings", "GB 20041.21-2008 Conduit Systems for Cable Management - Special Requirements for Rigid Conduit Systems", GB/T14823.2 "Conduits for Electrical Installation" Special requirements - Rigid insulating material flat conduit", ZBG33008 "Polyvinyl chloride plastic corrugated wire conduit" and IEC61386-21 Section 10.4.101 and Figure 102 and IEC61386-22 Section 10.4.102 and Figure 102 and other requirements.
 

IEC 61386-21 Figure 102 Gauge For Checking Minimum Inside Diameter Of Conduit System 0
 
Technical parameters:
 
1. Material: steel, surface hard chromium plated
2. Gauge selection table (unit: mm)
 

No. Gauge D+0.05 0 Sample nominal diameter Minimum inner diameter of sample Remark
Minimum inner diameter gauge of metal casing after bending: IEC61386-21
1 10.2 16 12.75  
2 13.1 20 16.38  
3 16.8 25 21.0  
Minimum inner diameter gauge of non-metallic casing after bending: IEC61386-22
1 8.6 16 10.75  
2 11.3 20 14.13  
3 14.6 25 18.25  
4 19.4 32 24.25  
5 25.0 40 31.25  
6 31.7 50 39.63  
7 41 63 51.25  
Note: Tolerance of other dimensions not specified is ±0.2mm, surface wear shall not exceed 0.01mm

 
3. There are 10 gauges in total, including 3 minimum inner diameter gauges for metal casing bending and 7 minimum inner diameter gauges for non-metal casing bending.
 

IEC 61386-21 Figure 102 Gauge For Checking Minimum Inside Diameter Of Conduit System 1

 