Standard applied: IEC60335-1 clause 23.3 and 25.14, IEC 60335-2-23 clause 23.3 and 11.101.
Test sample: Small household appliances (such as coffee pot, electric iron, toaster, luminaires and etc.), and skin or hair care appliances.
Feature: The test device adopts to PLC electrical control, 7-inch color touch screen intelligent operation system; servo motor controlling the test angle, high precision digital instrument, high performance digital frequency conversion, precise speed regulation, six number memory timer, multifunctional combined clamps, center gauge of rotation, flexing and rotation angles adjustable, 4kw output power, can also supply load current to test sample (1.25 times of test sample’s rated current). Test times (maximum of 999999 times), test speed, and test angles can be preset; it has electric current detection function. This device can meet the test requirements of most of small household electrical appliances, the applicable range is widely.
Technical Parameters:
Flexing or rotation angle | 0-360°. Can be preset |
Flexing or rotation speed | 0~60 rpm, can be preset |
Test times | 0~999999 times, can be preset and displayed |
Input Power | Single phase 220V, 60Hz |
Control | PLC programmable control |
Drive | Servo motor |
Operation | 7” Touch screen intelligent operation |
Max. output power | 4KW |
Output voltage | 0~250V |
Output current | 0~16A |
Max. carrying capacity | 30kg |
Test station | 1 station |
Specimen fixtures |
Universal fixtures for IEC60335-1 clause 25.14 test, 1 set
Universal fixture and a positioning platform which can be raised and lowered for IEC60335-1 clause 23.3 test, 1 set
* The is a guide rail on the bottom plate for moving the lifting platform part to the right side, to avoid affect sample placement when process other tests.
Universal fixture for IEC 60335-2-23 clause 11.101, 1 set
|
Temperature Measuring | Hand-held infrared thermometer, -50°C~380°C |
Load weights | 1N*1, 5N*1,10N*1 |
Common Faults and Treatments:
No. | Fault | Reason | Treatment |
1 |
Turn on the “Power” switch, but the indicator light not turn on | The external power supply is not connected | Please connect to the external power supply |
The fuse is broken | Find out the reason and change the fuse. | ||
The indicator light damaged | Replace the light | ||
2 |
Turn on the “Power” switch, Touchscreen not work | The internal DC24V power supply is in problem | Replace the DC24V power supply |
Touchscreen damaged | Replace the touchscreen | ||
3 | Touchscreen no response | Connection to PLC loose | Reconnect |
Touchscreen damaged | Replace the touchscreen | ||
4 | Load power no power supply | Load socket damaged | Replace the socket |
The fuse is broken | Change the fuse | ||
5 |
Press down “Start” button, but the manipulators do not work. |
The display value and preset value of test times are the same | Press “Count Cleared” button |
The E-STOP button is not reset | Release E-STOP button | ||
There is foreign object in the machine, the machinery is stuck | Remove the foreign object | ||
It is not under auto test mode | Press “Start” button | ||
Connection to motor loosen | Reconnect | ||
Not in starting position | Homing | ||
6 | Noise | Swivel speed low or too high | Reset the speed |
Connection to motor loosen | Reconnect |
|
MOQ: | 1 |
Price: | Negotiable |
Standard Packaging: | Plywood Case |
Delivery Period: | 30 Days |
Payment Method: | T/T |
Supply Capacity: | 20 Sets Per Month |
IEC 60335-2-23 Power Cord Flexibility Test Equipment PLC Control With Universal Fixtures
Product Information:
Standard applied: IEC60335-1 clause 23.3 and 25.14, IEC 60335-2-23 clause 23.3 and 11.101.
Test sample: Small household appliances (such as coffee pot, electric iron, toaster, luminaires and etc.), and skin or hair care appliances.
Feature: The test device adopts to PLC electrical control, 7-inch color touch screen intelligent operation system; servo motor controlling the test angle, high precision digital instrument, high performance digital frequency conversion, precise speed regulation, six number memory timer, multifunctional combined clamps, center gauge of rotation, flexing and rotation angles adjustable, 4kw output power, can also supply load current to test sample (1.25 times of test sample’s rated current). Test times (maximum of 999999 times), test speed, and test angles can be preset; it has electric current detection function. This device can meet the test requirements of most of small household electrical appliances, the applicable range is widely.
Technical Parameters:
Flexing or rotation angle | 0-360°. Can be preset |
Flexing or rotation speed | 0~60 rpm, can be preset |
Test times | 0~999999 times, can be preset and displayed |
Input Power | Single phase 220V, 60Hz |
Control | PLC programmable control |
Drive | Servo motor |
Operation | 7” Touch screen intelligent operation |
Max. output power | 4KW |
Output voltage | 0~250V |
Output current | 0~16A |
Max. carrying capacity | 30kg |
Test station | 1 station |
Specimen fixtures |
Universal fixtures for IEC60335-1 clause 25.14 test, 1 set
Universal fixture and a positioning platform which can be raised and lowered for IEC60335-1 clause 23.3 test, 1 set
* The is a guide rail on the bottom plate for moving the lifting platform part to the right side, to avoid affect sample placement when process other tests.
Universal fixture for IEC 60335-2-23 clause 11.101, 1 set
|
Temperature Measuring | Hand-held infrared thermometer, -50°C~380°C |
Load weights | 1N*1, 5N*1,10N*1 |
Common Faults and Treatments:
No. | Fault | Reason | Treatment |
1 |
Turn on the “Power” switch, but the indicator light not turn on | The external power supply is not connected | Please connect to the external power supply |
The fuse is broken | Find out the reason and change the fuse. | ||
The indicator light damaged | Replace the light | ||
2 |
Turn on the “Power” switch, Touchscreen not work | The internal DC24V power supply is in problem | Replace the DC24V power supply |
Touchscreen damaged | Replace the touchscreen | ||
3 | Touchscreen no response | Connection to PLC loose | Reconnect |
Touchscreen damaged | Replace the touchscreen | ||
4 | Load power no power supply | Load socket damaged | Replace the socket |
The fuse is broken | Change the fuse | ||
5 |
Press down “Start” button, but the manipulators do not work. |
The display value and preset value of test times are the same | Press “Count Cleared” button |
The E-STOP button is not reset | Release E-STOP button | ||
There is foreign object in the machine, the machinery is stuck | Remove the foreign object | ||
It is not under auto test mode | Press “Start” button | ||
Connection to motor loosen | Reconnect | ||
Not in starting position | Homing | ||
6 | Noise | Swivel speed low or too high | Reset the speed |
Connection to motor loosen | Reconnect |