logo

Coupler Heating Tester For Evaluating Heat Resistance Performance Testing IEC60320-1

Basic Properties
Place of Origin: China
Brand Name: Sinuo
Certification: Calibration Certificate (Cost Additional)
Model Number: SN2103
Trading Properties
Minimum Order Quantity: 1
Price: Customized
Payment Terms: T/T
Supply Ability: 20 sets per month
Specifications
Heating temp.: RT+10~160℃±2℃ Standard gauge: 3 Heating Gauges
Test station: Single Station Test items: Input Socket
Control method: Button Control Heating method: Electric Heating
Test time: 0-99h59m Center distance: Φ175
High Light:

Heat Resistance Performance Coupler Heating Tester

,

IEC60320-1 Coupler Heating Tester

,

Coupler Heating Tester

Product Description

 

Coupler Heating Tester For Evaluating Heat Resistance Performance Testing IEC60320-1

 

Product information:

 

Standard:IEC60320-1:2021 clause 18.2 and figure 5, IEC60320-3:2022.

Test purpose: used to evaluate the heat resistance performance of appliance couplers under thermal conditions or extreme heat conditions.

Power supply: AC220V±10%/50-60Hz, working temperature 5-35℃, humidity 30%-90%.

 

Coupler Heating Tester For Evaluating Heat Resistance Performance Testing IEC60320-1

Coupler Heating Tester For Evaluating Heat Resistance Performance Testing IEC60320-1

 

 

Technical Parameters:

 

Test station Single station
Electrical control method Button control, digital display
Heating method Electric heating, RT+10~160℃±2℃, can be preset
Test items C16: 10A heat-resistant appliance input socket: test 10A connector, test temperature 120°±2°;
C16A: 10A heat-resistant appliance input socket: test 10A connector, test temperature 155°±2°;
C22: 16A heat-resistant appliance input socket: test 16A connector, test temperature 155°±2°;
N: 10A heat-resistant appliance output socket: test 10A plug connector, test temperature 120°±2°;
P: 10A heat-resistant appliance output socket: test 10A plug connector, test temperature 155°±2°;
R: 16A heat-resistant appliance output socket: test 16A plug connector, test temperature 155°±2°;
Test time 0-99 hours and 59 minutes can be preset;
Coupler center distance Arranged uniformly in a circle of Φ175
Standard gauge The standard 10A heat-resistant, 10A extreme heat-resistant and 16A extreme heat-resistant appliance input sockets and appliance output sockets are heating gauges, 3 each of C16, C16A, C22, N, P and R, 18pcs in total.
 