Send Message
products
PRODUCTS DETAILS
Home > Products >
IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 20 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2117D
Test Station:
3 Stations
Voltage Value:
0~300V
Power Value:
0~1KW
Output Voltage:
0~280V
Display Accuracy:
0.5 Level
Control Method:
Touch Screen
Protection Time:
1~99S
Power Supply:
AC220/50Hz
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
20 sets per month
High Light:

Self Ballasted Lamp Switch Load Cabinet

,

IEC 60669-2-1 Lamp Switch Load Cabinet

Product Description

 

IEC 60669-2-1 Self-Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches

 

Product information:

 

The load cabinet conforms to the requirements of IEC60669-1:2017 clause 19.3 and IEC60669-2-1: 2015 figure 103, clause 19.109, IEC60669-2-1: 2021 clause 19.106.

 

It is suitable for the on-off capability and normal operating life test of switches for household and similar fixed electrical installations. Especially suitable for switches intended for self-ballasted lamp loads, which should withstand the electrical and thermal stresses that occur when controlling the LED circuit, without excessive damage or other harmful effects.

 

Main features:

 

1. This load cabinet has been preset with the load conditions required by the standard before leaving the factory. As long as the test voltage is adjusted to 230~ to 250V~, the operator presses the corresponding button on the touch screen with the same rated current and power of the switch to be tested, then its rated power, impulse waveform, Ipeak and I²t meet the corresponding requirements of the standard.

 

2. The operation is convenient and intuitive, the input voltage and output power are digital displayed, the current impact Ipeak current value and I2t energy value can be observed on the touch screen, and the numbers of random shock waveforms will be counted.

 

3. With 3 stations, 3 switches with different parameters can be tested at the same time.

 

4. With calibration mode and calibration dedicated port, built-in 90-degree closing plate, it is convenient to measure the output waveform, Ipeak current value and I²t energy value, which fully meets the requirements of the standard for equipment calibration.

 

5. This equipment is equipped with an automatic intelligent voltage regulating and stabilizing device (this device is especially suitable for use at night when the voltage rises), it can reach the required voltage value of 250V~ without needing to connect an external manual voltage regulator.

 

Main Technical parameters:

Approximate dimensions: width 770mm × width 960mm × height 1700mm, the color of the frame is blue, the side panels are light white, and the upper front is the operation control panel. On the panel, there are power supply control switch, product test voltage and power display instruments, alarms, touch screen, etc., inside the upper part of the cabinet, there are resistor and capacitor load combinations, AC contactors, and relays, on the lower part of the cabinet, there are connection terminals, which are connected with the sample through the wires to output current and provide load during the detection process.

1) Power supply: match client's local power supply requirements with ground wire.

2) Digital display voltage value: range 0~300V, accuracy 0.5 level.

3) Digital display power value: range 0~1KW, accuracy 0.5 level.

4) Number of output channels: 3 channels, namely 3 independent test stations.

5). Each channel has selection buttons with pre-set test modes, such as IEC-1 test modes (as per IEC 60669-1:2017) : 100W,150W, 200W, 250W; IEC-2 test modes (as per IEC 60669-2-1: 2002/AMD2: 2015): 100W, 150W,200W, 250W (these four test modes are in IEC-1 interface), 30W, 60W, 300W, 350W (these four test modes are in IEC-2 interface) and 15W, 400W in the User-defined interface shown as User-1 and User-4, and the remaining selection buttons in the User-defined interface shown as User-2 and User-3 can be defined by user by inputting the values through the touch screen interface.

6) The input voltage is adjustable to ensure the test voltage.

7) All working parameters are set, including W, Ipeak, I²t and impulse current waveform.

8), Ipeak, I²t and real-time waveform of impulse current are directly displayed on the touch screen interface, and the numbers of random impulse waveforms will be counted.

9) Each set of equipment provides a closing control device (the touch screen selects the "CAL" function), and it is conducted at a 90-degree angle each time. This function can be used for the initial adjustment of the equipment and the measurement calibration.

10). With long-breaking/long-conduction protection functions, the protection time can be preset from 1 to 99S, and it will alarm when it is under protection situation.

11). Use environment: temperature 5~40℃, relative humidity 20~90%RH, atmospheric pressure 80~106kpa; no severe vibration, no electromagnetic interference, no dust, corrosive gas, and a place with good heat dissipation.

 

IEC 60669-1: 2017 standard parameters:

Rated Power (W)

Ipeak

A

Distribution system: 220/380, 230/400/ 240/415

I2t

A2s

Distribution system: 220/380,

230/400/

240/415

15 22 0.08
30 41 0.3
60 73 1.2
100 108 2.8
150 142 5.5
200 170 9
250 192 13
300 209 16.5
350 223 20.5
400 235 24.5

 

IEC 60669-2-1: 2015 standard parameters:

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches 0

 

Basic principle of equipment:

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches 1

 

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches 2

 

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches 3

(Cooperate with a switch endurance test apparatus, the switch endurance test apparatus is optional, not included in SN2117D)

products
PRODUCTS DETAILS
IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 20 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2117D
Test Station:
3 Stations
Voltage Value:
0~300V
Power Value:
0~1KW
Output Voltage:
0~280V
Display Accuracy:
0.5 Level
Control Method:
Touch Screen
Protection Time:
1~99S
Power Supply:
AC220/50Hz
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
20 sets per month
High Light

Self Ballasted Lamp Switch Load Cabinet

,

IEC 60669-2-1 Lamp Switch Load Cabinet

Product Description

 

IEC 60669-2-1 Self-Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches

 

Product information:

 

The load cabinet conforms to the requirements of IEC60669-1:2017 clause 19.3 and IEC60669-2-1: 2015 figure 103, clause 19.109, IEC60669-2-1: 2021 clause 19.106.

 

It is suitable for the on-off capability and normal operating life test of switches for household and similar fixed electrical installations. Especially suitable for switches intended for self-ballasted lamp loads, which should withstand the electrical and thermal stresses that occur when controlling the LED circuit, without excessive damage or other harmful effects.

 

Main features:

 

1. This load cabinet has been preset with the load conditions required by the standard before leaving the factory. As long as the test voltage is adjusted to 230~ to 250V~, the operator presses the corresponding button on the touch screen with the same rated current and power of the switch to be tested, then its rated power, impulse waveform, Ipeak and I²t meet the corresponding requirements of the standard.

 

2. The operation is convenient and intuitive, the input voltage and output power are digital displayed, the current impact Ipeak current value and I2t energy value can be observed on the touch screen, and the numbers of random shock waveforms will be counted.

 

3. With 3 stations, 3 switches with different parameters can be tested at the same time.

 

4. With calibration mode and calibration dedicated port, built-in 90-degree closing plate, it is convenient to measure the output waveform, Ipeak current value and I²t energy value, which fully meets the requirements of the standard for equipment calibration.

 

5. This equipment is equipped with an automatic intelligent voltage regulating and stabilizing device (this device is especially suitable for use at night when the voltage rises), it can reach the required voltage value of 250V~ without needing to connect an external manual voltage regulator.

 

Main Technical parameters:

Approximate dimensions: width 770mm × width 960mm × height 1700mm, the color of the frame is blue, the side panels are light white, and the upper front is the operation control panel. On the panel, there are power supply control switch, product test voltage and power display instruments, alarms, touch screen, etc., inside the upper part of the cabinet, there are resistor and capacitor load combinations, AC contactors, and relays, on the lower part of the cabinet, there are connection terminals, which are connected with the sample through the wires to output current and provide load during the detection process.

1) Power supply: match client's local power supply requirements with ground wire.

2) Digital display voltage value: range 0~300V, accuracy 0.5 level.

3) Digital display power value: range 0~1KW, accuracy 0.5 level.

4) Number of output channels: 3 channels, namely 3 independent test stations.

5). Each channel has selection buttons with pre-set test modes, such as IEC-1 test modes (as per IEC 60669-1:2017) : 100W,150W, 200W, 250W; IEC-2 test modes (as per IEC 60669-2-1: 2002/AMD2: 2015): 100W, 150W,200W, 250W (these four test modes are in IEC-1 interface), 30W, 60W, 300W, 350W (these four test modes are in IEC-2 interface) and 15W, 400W in the User-defined interface shown as User-1 and User-4, and the remaining selection buttons in the User-defined interface shown as User-2 and User-3 can be defined by user by inputting the values through the touch screen interface.

6) The input voltage is adjustable to ensure the test voltage.

7) All working parameters are set, including W, Ipeak, I²t and impulse current waveform.

8), Ipeak, I²t and real-time waveform of impulse current are directly displayed on the touch screen interface, and the numbers of random impulse waveforms will be counted.

9) Each set of equipment provides a closing control device (the touch screen selects the "CAL" function), and it is conducted at a 90-degree angle each time. This function can be used for the initial adjustment of the equipment and the measurement calibration.

10). With long-breaking/long-conduction protection functions, the protection time can be preset from 1 to 99S, and it will alarm when it is under protection situation.

11). Use environment: temperature 5~40℃, relative humidity 20~90%RH, atmospheric pressure 80~106kpa; no severe vibration, no electromagnetic interference, no dust, corrosive gas, and a place with good heat dissipation.

 

IEC 60669-1: 2017 standard parameters:

Rated Power (W)

Ipeak

A

Distribution system: 220/380, 230/400/ 240/415

I2t

A2s

Distribution system: 220/380,

230/400/

240/415

15 22 0.08
30 41 0.3
60 73 1.2
100 108 2.8
150 142 5.5
200 170 9
250 192 13
300 209 16.5
350 223 20.5
400 235 24.5

 

IEC 60669-2-1: 2015 standard parameters:

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches 0

 

Basic principle of equipment:

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches 1

 

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches 2

 

IEC 60669-2-1 Self - Ballasted Lamp Switch Load Cabinet For Test Capability Of The Switches 3

(Cooperate with a switch endurance test apparatus, the switch endurance test apparatus is optional, not included in SN2117D)

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.