Home ProductsEnvironmental Test Chamber

Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2

Certification
China Sinuo Testing Equipment Co. , Limited certification
China Sinuo Testing Equipment Co. , Limited certification
Customer Reviews
Perfect on-site installation service, excellent training and technology support. Absolutely helps us a lot.

—— Aryan Das

Thanks. Your company is very professional, I am sure we will have good cooperation in the future.

—— Fernando Fuentealba

It's a great purchase, good products received with good packing, will back to you for next needs.

—— Sarah Rashad

I'm Online Chat Now

Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2

Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2
Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2 Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2 Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2 Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2

Large Image :  Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2

Product Details:
Place of Origin: China
Brand Name: Sinuo
Certification: Calibration Certificate(cost additional )
Model Number: SN886-4300
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Standard Exporting Plywood Case
Delivery Time: 30 days
Payment Terms: T/T
Supply Ability: 10 Sets / Month
Detailed Product Description
Rising Rate: ≤1.6℃/min (full Average) Cooling Rate: ≤1.0℃/min (full Average)
Temperature Fluctuation: ≤±0.5℃ (at Steady State) Temperature Uniformity: ≤2℃ (at Steady State)
Temperature Deviation: ±2.0℃ Humidity Deviation: ≤+2/-3%R.H
Material: SUS304 Stainless Steel Cooling Method: Air-cooling
High Light:

IEC60068-2 Humidity Heat Test Chamber

,

Walk In Humidity Heat Test Chamber

,

SUS304 Environmental Test Chamber

 

Walk-In Salt Spray Corrosion Humidity-Heat Test Chamber for Solar Panel IEC60068-2

 

Product Information For Walk-In Salt Spray Corrosion Humidity-Heat Test Chamber:

 

Solar panel walk-in constant temperature and humidity test chamber is mainly designed and manufactured according to standards of IEC 60068-2-78, IEC 1251:1993, IEC 61730 and etc. It is used to test photovoltaic modules and determine the ability of modules to withstand long-term moisture penetration. The purpose is to determine the ability of modules to resist heat cycles and humidity-heat tests. It is also suitable for ESS high and low temperature cyclic stress screening test or constant test for electrical and electronic products and other products, parts and materials, and for quality and reliability testing of products, parts and materials under simulated temperature changes.

The test room adopts PLC intelligent central integrated control, touch screen display and operation, it is equipped with sample placement brackets, and a slope at the entrance of the test room. The samples are convenient to be moved and placed. The whole system is simple to operate, and the whole machine is beautiful and generous.

 

Technical Parameter For Walk-In Salt Spray Corrosion Humidity-Heat Test Chamber:

 

Item Specifications
Name Solar Panel Walk-in Constant Temperature and Humidity Test Chamber
Model SN886-4300
Working studio size (mm) 1100×2600×1500 W*D*H
Numbers of samples that can be placed 3 pcs, Sample size not larger than 1200× 2400×45 mm W*D*H
Chamber external size(mm) Approx. 1850×2850×2720 W*D*H
Test Range Temperature -40℃~+100℃
Humidity

20%~98%RH (Shown as following)

 

Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2 0

Heating and cooling rate Rising rate ≤1.6℃/min (full average)
Cooling rate ≤1.0℃/min (full average)
Temperature fluctuation ≤±0.5℃ (at steady state)
Temperature uniformity ≤2℃ (at steady state)
Temperature deviation ±2.0℃
Humidity Deviation

≤+2/-3%R.H. (when the humidity>75%R.H.)

≤±5%R.H. (when the humidity>≤75%R.H.)

Test contents 1. Thermal cycle: cycle from -40°C±2.0°C to 85°C±2.0°C, the temperature change rate is less than 100°C/h, the constant temperature time is at least 10min, and one cycle does not exceed 6h
2. Humidity-heat test: 85°C±2.0°C, 85%±5%, test time 1000h
Noise ≤75dB
Weight Approx. 1800KG
Test method applied

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

Note: The above performance indicators are measured at room temperature +25°C without samples.
Material Inner wall material SUS304# stainless steel plate
Outer wall material Cold rolled steel plate, pickling and phosphating advanced powder baking paint
Insulation material rigid polyurethane foam + glass fiber
Structure Air duct parts Centrifugal fan; the air outlet can adjust the air volume, height and return air volume
Door Single open door, with handle-type non-reaction handle, the door is equipped with an observation window, lighting lamp, window/door frame anti-condensation electric heating device, Door size: SN886-4300: (approx.) 1.1*1.5M, SN886-5800 (approx.) 1.5*1.5M
Observation window The door with one conductive film explosion-proof tempered glass observation window (with anti-condensation function), window size: 500W×600H (mm)
Fan Long axis centrifugal fan
Sample mounting rack Will be customized to match client’s sample
Impeller Use stainless steel impeller imported from Taiwan
Heater Nickel-chromium alloy electric heater
Refrigeration Compressor French Tecumseh compressor

 

Evaporator

 

Fin type evaporator
Refrigerating method Mechanical compressor cascade
Cooling method Air-cooling
Temperature control instrument 10-inch smart LCD touch programmable controller
Lead hole Φ100mm, 1 pc, equipped with a special foam rubber plug (located on the left side of the chamber)
 

System Principle For Walk-In Salt Spray Corrosion Humidity-Heat Test Chamber:

 

The PLC is used to control the cooling of the compressor, the heating of the heat pipe and the humidification of the humidifier, cooperating with the indoor air duct to realize the control of the temperature and humidity in the chamber.

Forced circulation ventilation, balance temperature regulation method. The control system controls the output of the heater through the PID automatic calculation output according to the temperature point set by the system, and finally reaches a dynamic balance.

 

Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2 1

 

Chamber structure For Walk-In Salt Spray Corrosion Humidity-Heat Test Chamber:

 

The test chamber consists of a control cabinet, a chamber body, a sample mounting bracket and a slope.

 

Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2 2
 
Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2 3
 
Walk In Salt Spray Constant Humidity Heat Test Chamber For Solar Panel IEC60068-2 4
 

Contact Details
Sinuo Testing Equipment Co. , Limited

Contact Person: Sinuo

Tel: +8618102704215

Send your inquiry directly to us (0 / 3000)