MOQ: | 1 |
Price: | Customized |
Standard Packaging: | Carton Box |
Delivery Period: | 5 Days |
Payment Method: | L/C, T/T, Western Union, MoneyGram |
Supply Capacity: | 100 Sets Per Month |
IEC 60335-2-9 Figure 102 Stainless Steel 4.5 kg Load for Testing Rotating Spits
Product overview:
The testing rotating spits load complies with IEC 60335-2-9 clause 3.1.9.102 Figure102,
IEC60335-2-6 clause 3.1.9.104 Figure 103, the equivalent mass is about 4. 5kg.
It is made of stainless steel.
Size: Ф100+20 mm * 85+10 mm.
Technical Characteristics:
Applied Standards & Clauses | IEC 60335-2-9 clause 3.1.9.102 Figure102 IEC60335-2-6 clause 3.1.9.104 Figure 103 |
Load Diameter | Ф100+20 mm |
Load Thickness | 85+10 mm |
Load Material | Stainless steel |
Load Equivalent Mass | 4.5 kg |
How to test the ovens or grills' rotating spits? (extracted from IEC 60335-2-6:2018 clause 3.1.9.103)
Rotating spits in ovens or grills are operated with the load on the rotating spit as shown in Figure 103. The appliance is operated taking into account the instructions with regard to
-the heating elements to be operated;
-the setting of the thermal control;
-the position of t he door and grill pan.
In the absence of such insstructions, the contril is adjusted to its highest setting and the door is fully open or is placed in the most unfavourable intermediate position in which it may be left.
Any grill pan is placed in its lowest position.
MOQ: | 1 |
Price: | Customized |
Standard Packaging: | Carton Box |
Delivery Period: | 5 Days |
Payment Method: | L/C, T/T, Western Union, MoneyGram |
Supply Capacity: | 100 Sets Per Month |
IEC 60335-2-9 Figure 102 Stainless Steel 4.5 kg Load for Testing Rotating Spits
Product overview:
The testing rotating spits load complies with IEC 60335-2-9 clause 3.1.9.102 Figure102,
IEC60335-2-6 clause 3.1.9.104 Figure 103, the equivalent mass is about 4. 5kg.
It is made of stainless steel.
Size: Ф100+20 mm * 85+10 mm.
Technical Characteristics:
Applied Standards & Clauses | IEC 60335-2-9 clause 3.1.9.102 Figure102 IEC60335-2-6 clause 3.1.9.104 Figure 103 |
Load Diameter | Ф100+20 mm |
Load Thickness | 85+10 mm |
Load Material | Stainless steel |
Load Equivalent Mass | 4.5 kg |
How to test the ovens or grills' rotating spits? (extracted from IEC 60335-2-6:2018 clause 3.1.9.103)
Rotating spits in ovens or grills are operated with the load on the rotating spit as shown in Figure 103. The appliance is operated taking into account the instructions with regard to
-the heating elements to be operated;
-the setting of the thermal control;
-the position of t he door and grill pan.
In the absence of such insstructions, the contril is adjusted to its highest setting and the door is fully open or is placed in the most unfavourable intermediate position in which it may be left.
Any grill pan is placed in its lowest position.