Send Message
products
PRODUCTS DETAILS
Home > Products >
50W 500W Flammability Test Chamber Horizontal / Vertical Flame UL94 Fire Hazard Test

50W 500W Flammability Test Chamber Horizontal / Vertical Flame UL94 Fire Hazard Test

MOQ: 1
Price: Negotiable
Standard Packaging: Plywood
Delivery Period: 20 Days
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN771A
Control:
Mitsubishi PLC
Display:
7" Weiview Touch Screen
Combustion Angle:
0°, 20°, 45°
Working Volume:
0.75m³
Chamber Material:
Stainless Steel
Type Of Gas:
Methane Or Coal Gas
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
20 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
High Light:

flame test chamber

,

flammability test apparatus

Product Description

IEC 60695-11-10 / 20 50W 500W Horizontal And Vertical Flame Test Apparatus PLC Control Fire Hazard Testing Chamber

 

Overview:

 

This horizontal and vertical flame test chamber simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is not less than 250kg/m³ according to ISO845 test method.

 

Standards:

 

UL94

IEC60695-11-3

IEC60695-11-4

IEC60695-11-10

IEC60695-11-20

 

Technical Parameters:

 

 
Flame power 50W 500W
Conforming to standards UL94, IEC60695-11-4, IEC60695-11-10 UL94, IEC60695-11-3, IEC60695-11-20
Timing 0~9999, resolution:0.1s, can be set and displayed on touch sceen 0~9999, resolution:0.1s, can be set and displayed on touch sceen
Combustion angle 0°, 20°, 45° 0°, 20°, 45°
Gas pressure 0.1 MPa 0.1 MPa
Height of flame Total height 20±2mm Inner flame 40±2mm total height 125
Distance for temperature measurement 10±1mm 55±1mm
Standard for blast burner IEC60698-11-4, UL94 IEC60695-11-3, UL94
Temperature testing Max. 1100℃, thermocouple: type K Max. 1100℃, thermocouple: type K
Gas flow rate 105 ml/min±5 ml/min 965 ml/min±30 ml/min
Water column height <10mm 125mm±5mm
Temperature rise time From 100℃±5℃ to 700℃±3℃ is 44s±2s From 100℃±5℃ to 700℃±3℃ is 54s±2s
Accuracy of flow rate 1% 1%
Weight of copper block

Ф5.5mm,

1.76 g±0.01 g

(before drilling)

Ф9mm,

10g±0.05 g

(before drilling)

Type of gas Methane or coal gas Methane or coal gas
Volume of chamber 0.75m³, black inner painted
Control Mitsubishi PLC
Display 7" Weiview Touch Screen
Using environment

15 °C to 35 °C temperature,

45 % to 75 % relative humidity

 
 
Features:

 

This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, chamber body are made full of stainless steel, large observation window, imported thermocouple of high precision, PLC control and touch screen display, also equiped with remote controller.

50W 500W Flammability Test Chamber Horizontal / Vertical Flame UL94 Fire Hazard Test 0

Sinuo offers kinds of testing equipment based on the standard requirements of IEC, BS, VDE, UL, GB, ISO and etc., and customize testing systems or devices based on clients' specific requirements, also Sinuo can offer proposals for building an entire laboratory. We have our own senior professional technical team and cooperated with universities and research institutions, together with our strength manufacturing ability, we can offer clients fast reponses  and one-stop service.

 

50W 500W Flammability Test Chamber Horizontal / Vertical Flame UL94 Fire Hazard Test 1

 
products
PRODUCTS DETAILS
50W 500W Flammability Test Chamber Horizontal / Vertical Flame UL94 Fire Hazard Test
MOQ: 1
Price: Negotiable
Standard Packaging: Plywood
Delivery Period: 20 Days
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN771A
Control:
Mitsubishi PLC
Display:
7" Weiview Touch Screen
Combustion Angle:
0°, 20°, 45°
Working Volume:
0.75m³
Chamber Material:
Stainless Steel
Type Of Gas:
Methane Or Coal Gas
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
20 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
High Light

flame test chamber

,

flammability test apparatus

Product Description

IEC 60695-11-10 / 20 50W 500W Horizontal And Vertical Flame Test Apparatus PLC Control Fire Hazard Testing Chamber

 

Overview:

 

This horizontal and vertical flame test chamber simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is not less than 250kg/m³ according to ISO845 test method.

 

Standards:

 

UL94

IEC60695-11-3

IEC60695-11-4

IEC60695-11-10

IEC60695-11-20

 

Technical Parameters:

 

 
Flame power 50W 500W
Conforming to standards UL94, IEC60695-11-4, IEC60695-11-10 UL94, IEC60695-11-3, IEC60695-11-20
Timing 0~9999, resolution:0.1s, can be set and displayed on touch sceen 0~9999, resolution:0.1s, can be set and displayed on touch sceen
Combustion angle 0°, 20°, 45° 0°, 20°, 45°
Gas pressure 0.1 MPa 0.1 MPa
Height of flame Total height 20±2mm Inner flame 40±2mm total height 125
Distance for temperature measurement 10±1mm 55±1mm
Standard for blast burner IEC60698-11-4, UL94 IEC60695-11-3, UL94
Temperature testing Max. 1100℃, thermocouple: type K Max. 1100℃, thermocouple: type K
Gas flow rate 105 ml/min±5 ml/min 965 ml/min±30 ml/min
Water column height <10mm 125mm±5mm
Temperature rise time From 100℃±5℃ to 700℃±3℃ is 44s±2s From 100℃±5℃ to 700℃±3℃ is 54s±2s
Accuracy of flow rate 1% 1%
Weight of copper block

Ф5.5mm,

1.76 g±0.01 g

(before drilling)

Ф9mm,

10g±0.05 g

(before drilling)

Type of gas Methane or coal gas Methane or coal gas
Volume of chamber 0.75m³, black inner painted
Control Mitsubishi PLC
Display 7" Weiview Touch Screen
Using environment

15 °C to 35 °C temperature,

45 % to 75 % relative humidity

 
 
Features:

 

This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, chamber body are made full of stainless steel, large observation window, imported thermocouple of high precision, PLC control and touch screen display, also equiped with remote controller.

50W 500W Flammability Test Chamber Horizontal / Vertical Flame UL94 Fire Hazard Test 0

Sinuo offers kinds of testing equipment based on the standard requirements of IEC, BS, VDE, UL, GB, ISO and etc., and customize testing systems or devices based on clients' specific requirements, also Sinuo can offer proposals for building an entire laboratory. We have our own senior professional technical team and cooperated with universities and research institutions, together with our strength manufacturing ability, we can offer clients fast reponses  and one-stop service.

 

50W 500W Flammability Test Chamber Horizontal / Vertical Flame UL94 Fire Hazard Test 1

 
Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.