IEC 60695-11-10 / 20 50W 500W Horizontal And Vertical Flame Test Apparatus PLC Control Fire Hazard Testing Chamber
Overview:
This horizontal and vertical flame test chamber simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is not less than 250kg/m³ according to ISO845 test method.
Standards:
UL94
IEC60695-11-3
IEC60695-11-4
IEC60695-11-10
IEC60695-11-20
Technical Parameters:
Flame power | 50W | 500W |
Conforming to standards | UL94, IEC60695-11-4, IEC60695-11-10 | UL94, IEC60695-11-3, IEC60695-11-20 |
Timing | 0~9999, resolution:0.1s, can be set and displayed on touch sceen | 0~9999, resolution:0.1s, can be set and displayed on touch sceen |
Combustion angle | 0°, 20°, 45° | 0°, 20°, 45° |
Gas pressure | 0.1 MPa | 0.1 MPa |
Height of flame | Total height 20±2mm | Inner flame 40±2mm total height 125 |
Distance for temperature measurement | 10±1mm | 55±1mm |
Standard for blast burner | IEC60698-11-4, UL94 | IEC60695-11-3, UL94 |
Temperature testing | Max. 1100℃, thermocouple: type K | Max. 1100℃, thermocouple: type K |
Gas flow rate | 105 ml/min±5 ml/min | 965 ml/min±30 ml/min |
Water column height | <10mm | 125mm±5mm |
Temperature rise time | From 100℃±5℃ to 700℃±3℃ is 44s±2s | From 100℃±5℃ to 700℃±3℃ is 54s±2s |
Accuracy of flow rate | 1% | 1% |
Weight of copper block |
Ф5.5mm, 1.76 g±0.01 g (before drilling) |
Ф9mm, 10g±0.05 g (before drilling) |
Type of gas | Methane or coal gas | Methane or coal gas |
Volume of chamber | 0.75m³, black inner painted | |
Control | Mitsubishi PLC | |
Display | 7" Weiview Touch Screen | |
Using environment |
15 °C to 35 °C temperature, 45 % to 75 % relative humidity |
This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, chamber body are made full of stainless steel, large observation window, imported thermocouple of high precision, PLC control and touch screen display, also equiped with remote controller.
Sinuo offers kinds of testing equipment based on the standard requirements of IEC, BS, VDE, UL, GB, ISO and etc., and customize testing systems or devices based on clients' specific requirements, also Sinuo can offer proposals for building an entire laboratory. We have our own senior professional technical team and cooperated with universities and research institutions, together with our strength manufacturing ability, we can offer clients fast reponses and one-stop service.
|
MOQ: | 1 |
Price: | Negotiable |
Standard Packaging: | Plywood |
Delivery Period: | 20 Days |
Payment Method: | T/T, L/C, Western Union, MoneyGram |
Supply Capacity: | 10 Sets Per Month |
IEC 60695-11-10 / 20 50W 500W Horizontal And Vertical Flame Test Apparatus PLC Control Fire Hazard Testing Chamber
Overview:
This horizontal and vertical flame test chamber simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is not less than 250kg/m³ according to ISO845 test method.
Standards:
UL94
IEC60695-11-3
IEC60695-11-4
IEC60695-11-10
IEC60695-11-20
Technical Parameters:
Flame power | 50W | 500W |
Conforming to standards | UL94, IEC60695-11-4, IEC60695-11-10 | UL94, IEC60695-11-3, IEC60695-11-20 |
Timing | 0~9999, resolution:0.1s, can be set and displayed on touch sceen | 0~9999, resolution:0.1s, can be set and displayed on touch sceen |
Combustion angle | 0°, 20°, 45° | 0°, 20°, 45° |
Gas pressure | 0.1 MPa | 0.1 MPa |
Height of flame | Total height 20±2mm | Inner flame 40±2mm total height 125 |
Distance for temperature measurement | 10±1mm | 55±1mm |
Standard for blast burner | IEC60698-11-4, UL94 | IEC60695-11-3, UL94 |
Temperature testing | Max. 1100℃, thermocouple: type K | Max. 1100℃, thermocouple: type K |
Gas flow rate | 105 ml/min±5 ml/min | 965 ml/min±30 ml/min |
Water column height | <10mm | 125mm±5mm |
Temperature rise time | From 100℃±5℃ to 700℃±3℃ is 44s±2s | From 100℃±5℃ to 700℃±3℃ is 54s±2s |
Accuracy of flow rate | 1% | 1% |
Weight of copper block |
Ф5.5mm, 1.76 g±0.01 g (before drilling) |
Ф9mm, 10g±0.05 g (before drilling) |
Type of gas | Methane or coal gas | Methane or coal gas |
Volume of chamber | 0.75m³, black inner painted | |
Control | Mitsubishi PLC | |
Display | 7" Weiview Touch Screen | |
Using environment |
15 °C to 35 °C temperature, 45 % to 75 % relative humidity |
This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, chamber body are made full of stainless steel, large observation window, imported thermocouple of high precision, PLC control and touch screen display, also equiped with remote controller.
Sinuo offers kinds of testing equipment based on the standard requirements of IEC, BS, VDE, UL, GB, ISO and etc., and customize testing systems or devices based on clients' specific requirements, also Sinuo can offer proposals for building an entire laboratory. We have our own senior professional technical team and cooperated with universities and research institutions, together with our strength manufacturing ability, we can offer clients fast reponses and one-stop service.