IEC 60587:2022 Electrical Insulating Material High Voltage Leakage Tracking Test Apparatus

IEC 60587:2022 Electrical Insulating Material High Voltage Leakage Tracking Test Apparatus

MOQ: 1
Price: Negotiable
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 20 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN774B
Test Voltage:
AC 1000 V ~ 6000 V
Transformer Specification:
220V To 6000V
Protective Resistor:
2.5 KV, 3.5 KV And 4.5 KV
Power Wirewound Non-Inductive:
6 KV: 33 KΩ/200 W
Power Channel:
1 Power Channel
Working Stations:
5 Test Stations
Electrodes Distance:
50 ± 0.5 Mm
Inclination Angle:
45° ± 2°
Highlight:

High Voltage Leakage Tracking Test Apparatus

,

Insulating Material Leakage Tracking Test Apparatus

Product Description
IEC 60587:2022 Electrical Insulating Material High Voltage Leakage Tracking Test Apparatus
Product Overview

The SN774B high-voltage leakage tracking test instrument is designed and manufactured in compliance with GB/T 6553-2024 and IEC 60587:2022 standards. This equipment evaluates the resistance to tracking and erosion of electrical insulating materials, including thermosetting/thermoplastic plastics, insulators, and cable insulating materials under power frequency high voltage with contaminated electrolyte.

Utilizing Method 1: Constant Voltage Method as specified in Clause 6.4 of GB/T 6553-2024 (IEC 60587:2022), this apparatus is suitable for inclined specimens with liquid contaminants for tracking and erosion resistance grading. It supports common grading voltages of 2.5 kV, 3.5 kV, and 4.5 kV.

Electrical System Parameters
Input Power Supply
Parameter Specification
Rated Voltage AC 220V ±10%, 50 Hz
Power Frequency Range 45 Hz ~ 65 Hz
Total Harmonic Distortion of Sine Voltage ≤ 5%
Voltage Regulator 0~250V adjustable, capacity: 5 kVA
High-Voltage Output & Related Electrical Specifications
Parameter Specification
Test Voltage AC 1000 V ~ 6000 V, continuously stepless adjustable
Voltage Stabilization Accuracy ≤ ±5%
Transformer Specification 220V to 6000V transformation, capacity ≥ 5 kVA
Short-Circuit Current of Single Specimen Output ≥ 100 mA
Series Protective Resistor 2.5 kV: 1 kΩ/200 W
3.5 kV: 1.5 kΩ/200 W
4.5 kV: 3 kΩ/200 W
6 kV: 33 kΩ/200 W
Over-Current Protection When the current of high-voltage loop reaches 60 mA, the delay relay acts after 3 s ±1 s, automatically cuts off high voltage and triggers audible & visual alarm
Voltage Display Displayed via touch screen
Power Channel & Working Stations 1 power channel; 5 test stations with automatic switching for sequential testing
Tooling & Fixture System
Component Specification
Electrode Material & Thickness Stainless steel electrode, thickness: 0.5 mm (one pair of upper and lower electrodes, manufactured per standard Figure 6)
Spacing Between Upper and Lower Electrodes 50 ± 0.5 mm
Specimen Inclination Angle The mounting surface forms an angle of 45° ±2° with the horizontal plane, adjustable and lockable
Standard Specimen Dimension ≥ 50 mm * 120 mm * 6 mm
Working Station Configuration 5 sets of fixture clamps; 1 high-voltage supply loop for sequential power supply to 5 specimens, equipped with over-current protection
Contaminant Liquid Supply System
Contaminant Liquid Formula

Prepared with distilled water, the mixed solution contains (0.1 ± 0.002) % analytical grade ammonium chloride (NH₄Cl) and (0.02 ± 0.002) % isooctylphenoxy polyethoxy ethanol (non-ionic wetting agent) by mass fraction.

Preparation method: Add 2000 mL distilled water into a measuring cup, weigh 2 g analytical grade NH₄Cl solid and 0.4 g isooctylphenoxy polyethoxy ethanol, pour into distilled water and stir evenly with a glass rod.

Filter Paper Requirements

Filter paper thickness: 0.2 ± 0.02 mm, cut into specified shape and placed between upper electrode and specimen. Use 8 layers if thicker filter paper is adopted.

Peristaltic Pump Dripping

Drip drive: 1 group, switching control, using a precision peristaltic pump for dripping, flow rate range 0.00185~20 ml/min, operating speed 0.1~50 rpm, flow accuracy error: <0.2%.

Standard Test Parameters Matching Table
Standard Test Parameters Matching Table for IEC 60587:2022 High Voltage Tracking Test Apparatus
Chamber & Environmental Structure
Component Specification
Test Chamber Material & Dimension Inner chamber: 304 stainless steel; Dimension (W*D*H): 800*750*850 mm
Observation Window Front door with tempered explosion-proof observation window
Exhaust System Built-in forced exhaust system for automatic discharge of test waste gas
Waste Liquid Recovery Waste liquid tank at chamber bottom, waste liquid is automatically collected into waste liquid barrel
Safety Protection High-voltage interlock door (high voltage cuts off once door is opened); Complete equipment grounding; Insulation protection for high-voltage area
Operating Ambient Conditions Temperature: 23 ℃ ±2 ℃; Humidity: 45% ~ 75% RH
Control System
  • Main Controller: PLC + 7-inch industrial touch screen with Chinese operation interface; supports Method 1 (constant voltage timing: 0 ~ 9999 h)
  • Data Function: Real-time display of voltage, loop current and test time; automatic judgment of pass/failure or breakdown after test completion; data storage and report export via U disk
  • Timing Function: Total test duration is programmable within 0 ~ 9999 h; automatic shutdown after standard 6-hour test
  • Process Control: Set contaminant flow rate and series resistance according to standard table, and set 6-hour liquid dripping time for each group of specimens. Raise voltage to 2.5 kV / 3.5 kV / 4.5 kV after parameter setting, then start liquid dripping and timing. The system stops automatically when dripping lasts for 6 hours. For tests at other voltages, use another 5 specimens for each target voltage. The constant tracking voltage is the maximum voltage at which all five specimens remain intact after 6-hour test
Control System Interface of IEC 60587:2022 High Voltage Tracking Test Apparatus
Overall Dimension & Weight
Parameter Specification
Overall Dimension (L*W*H) Approx. 900*800*1550 mm
Net Weight Approx. 185 kg
Overall View of IEC 60587:2022 Electrical Insulating Material High Voltage Tracking Test Apparatus
Products
PRODUCTS DETAILS
IEC 60587:2022 Electrical Insulating Material High Voltage Leakage Tracking Test Apparatus
MOQ: 1
Price: Negotiable
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 20 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN774B
Test Voltage:
AC 1000 V ~ 6000 V
Transformer Specification:
220V To 6000V
Protective Resistor:
2.5 KV, 3.5 KV And 4.5 KV
Power Wirewound Non-Inductive:
6 KV: 33 KΩ/200 W
Power Channel:
1 Power Channel
Working Stations:
5 Test Stations
Electrodes Distance:
50 ± 0.5 Mm
Inclination Angle:
45° ± 2°
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
20 Sets Per Month
Highlight

High Voltage Leakage Tracking Test Apparatus

,

Insulating Material Leakage Tracking Test Apparatus

Product Description
IEC 60587:2022 Electrical Insulating Material High Voltage Leakage Tracking Test Apparatus
Product Overview

The SN774B high-voltage leakage tracking test instrument is designed and manufactured in compliance with GB/T 6553-2024 and IEC 60587:2022 standards. This equipment evaluates the resistance to tracking and erosion of electrical insulating materials, including thermosetting/thermoplastic plastics, insulators, and cable insulating materials under power frequency high voltage with contaminated electrolyte.

Utilizing Method 1: Constant Voltage Method as specified in Clause 6.4 of GB/T 6553-2024 (IEC 60587:2022), this apparatus is suitable for inclined specimens with liquid contaminants for tracking and erosion resistance grading. It supports common grading voltages of 2.5 kV, 3.5 kV, and 4.5 kV.

Electrical System Parameters
Input Power Supply
Parameter Specification
Rated Voltage AC 220V ±10%, 50 Hz
Power Frequency Range 45 Hz ~ 65 Hz
Total Harmonic Distortion of Sine Voltage ≤ 5%
Voltage Regulator 0~250V adjustable, capacity: 5 kVA
High-Voltage Output & Related Electrical Specifications
Parameter Specification
Test Voltage AC 1000 V ~ 6000 V, continuously stepless adjustable
Voltage Stabilization Accuracy ≤ ±5%
Transformer Specification 220V to 6000V transformation, capacity ≥ 5 kVA
Short-Circuit Current of Single Specimen Output ≥ 100 mA
Series Protective Resistor 2.5 kV: 1 kΩ/200 W
3.5 kV: 1.5 kΩ/200 W
4.5 kV: 3 kΩ/200 W
6 kV: 33 kΩ/200 W
Over-Current Protection When the current of high-voltage loop reaches 60 mA, the delay relay acts after 3 s ±1 s, automatically cuts off high voltage and triggers audible & visual alarm
Voltage Display Displayed via touch screen
Power Channel & Working Stations 1 power channel; 5 test stations with automatic switching for sequential testing
Tooling & Fixture System
Component Specification
Electrode Material & Thickness Stainless steel electrode, thickness: 0.5 mm (one pair of upper and lower electrodes, manufactured per standard Figure 6)
Spacing Between Upper and Lower Electrodes 50 ± 0.5 mm
Specimen Inclination Angle The mounting surface forms an angle of 45° ±2° with the horizontal plane, adjustable and lockable
Standard Specimen Dimension ≥ 50 mm * 120 mm * 6 mm
Working Station Configuration 5 sets of fixture clamps; 1 high-voltage supply loop for sequential power supply to 5 specimens, equipped with over-current protection
Contaminant Liquid Supply System
Contaminant Liquid Formula

Prepared with distilled water, the mixed solution contains (0.1 ± 0.002) % analytical grade ammonium chloride (NH₄Cl) and (0.02 ± 0.002) % isooctylphenoxy polyethoxy ethanol (non-ionic wetting agent) by mass fraction.

Preparation method: Add 2000 mL distilled water into a measuring cup, weigh 2 g analytical grade NH₄Cl solid and 0.4 g isooctylphenoxy polyethoxy ethanol, pour into distilled water and stir evenly with a glass rod.

Filter Paper Requirements

Filter paper thickness: 0.2 ± 0.02 mm, cut into specified shape and placed between upper electrode and specimen. Use 8 layers if thicker filter paper is adopted.

Peristaltic Pump Dripping

Drip drive: 1 group, switching control, using a precision peristaltic pump for dripping, flow rate range 0.00185~20 ml/min, operating speed 0.1~50 rpm, flow accuracy error: <0.2%.

Standard Test Parameters Matching Table
Standard Test Parameters Matching Table for IEC 60587:2022 High Voltage Tracking Test Apparatus
Chamber & Environmental Structure
Component Specification
Test Chamber Material & Dimension Inner chamber: 304 stainless steel; Dimension (W*D*H): 800*750*850 mm
Observation Window Front door with tempered explosion-proof observation window
Exhaust System Built-in forced exhaust system for automatic discharge of test waste gas
Waste Liquid Recovery Waste liquid tank at chamber bottom, waste liquid is automatically collected into waste liquid barrel
Safety Protection High-voltage interlock door (high voltage cuts off once door is opened); Complete equipment grounding; Insulation protection for high-voltage area
Operating Ambient Conditions Temperature: 23 ℃ ±2 ℃; Humidity: 45% ~ 75% RH
Control System
  • Main Controller: PLC + 7-inch industrial touch screen with Chinese operation interface; supports Method 1 (constant voltage timing: 0 ~ 9999 h)
  • Data Function: Real-time display of voltage, loop current and test time; automatic judgment of pass/failure or breakdown after test completion; data storage and report export via U disk
  • Timing Function: Total test duration is programmable within 0 ~ 9999 h; automatic shutdown after standard 6-hour test
  • Process Control: Set contaminant flow rate and series resistance according to standard table, and set 6-hour liquid dripping time for each group of specimens. Raise voltage to 2.5 kV / 3.5 kV / 4.5 kV after parameter setting, then start liquid dripping and timing. The system stops automatically when dripping lasts for 6 hours. For tests at other voltages, use another 5 specimens for each target voltage. The constant tracking voltage is the maximum voltage at which all five specimens remain intact after 6-hour test
Control System Interface of IEC 60587:2022 High Voltage Tracking Test Apparatus
Overall Dimension & Weight
Parameter Specification
Overall Dimension (L*W*H) Approx. 900*800*1550 mm
Net Weight Approx. 185 kg
Overall View of IEC 60587:2022 Electrical Insulating Material High Voltage Tracking Test Apparatus