Our Glow Wire Test Apparatus is engineered to meet the requirements of IEC 60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC 60695-2-13, IEC 60335 clause 30, IEC 60598, and UL 746A.
It simulates the thermal stress test of a glowing component or heat source, such as an overload resistance or ignition source. It is used for fire hazard testing and no-flame ignition source fire tests, measuring the initiation temperature and flammability index of glowing filaments for electric, electronic, and household appliances.
The apparatus adopts PLC control with a 7-inch color touch screen and a digital stepping motor for precise positioning and fast adjustment after specimen replacement. An imported B+B K thermocouple ensures stable and accurate temperature measurement.
Fire hazard safety testing for electrical and electronic products, household appliances, and insulation materials. It is used to determine material ignition temperature and flammability index for product safety certification.
| Control & Display | Integrated PLC & 7" color touch screen |
|---|---|
| Glowing Element | Φ4 mm ± 0.04 mm Ni/Cr (77/20) special standard ring shape, horizontal standing |
| Thermocouple | 1 mm imported K thermocouple (Brand: American B+B); armour temperature resistance 1100°C (better than the standard of 1050°C) |
| Temperature Precision | 500°C–750°C +10%, 750°C–960°C +10%; temperature fluctuation < 3°C |
| Temperature Sensing Delay | 1.7 s |
| Thermostat | 12 bit A/D ±0.05% |
| Specimen Pressure on Glowing Filament | 0.95 N ± 0.1 N (adjustable) |
| Maximum Depth of Heating | 7 mm ± 0.5 mm |
| Specimen Movement Speed | Approx. 13 mm/s |
| Testing Time | 30 s ± 0.1 s (1 s – 999.9 s can be preset) |
| Thickness of Ignite Bedding Board | Thickness 10 mm, white pine board cover, 12 g/m² – 30 g/m² standard silk paper |
| Volume of Test Site | ≥ 0.5 m³, black background, background illuminance ≤ 20 Lx |
| Dimension and Weight | W: 1130 mm × D: 600 mm × H: 1400 mm, gas vent: 100 mm, 115 KGS |
| Power | Single phase AC 220 V ±10% / 50 Hz |
| Standard | IEC 60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC 60695-2-13, UL 746A, IEC 60335, IEC 60598, etc. |
|
|
| MOQ: | 1 |
| Price: | Negotiable |
| Standard Packaging: | Plywood Case |
| Delivery Period: | 30 Days |
| Payment Method: | T/T |
| Supply Capacity: | 10 Sets Per Month |
Our Glow Wire Test Apparatus is engineered to meet the requirements of IEC 60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC 60695-2-13, IEC 60335 clause 30, IEC 60598, and UL 746A.
It simulates the thermal stress test of a glowing component or heat source, such as an overload resistance or ignition source. It is used for fire hazard testing and no-flame ignition source fire tests, measuring the initiation temperature and flammability index of glowing filaments for electric, electronic, and household appliances.
The apparatus adopts PLC control with a 7-inch color touch screen and a digital stepping motor for precise positioning and fast adjustment after specimen replacement. An imported B+B K thermocouple ensures stable and accurate temperature measurement.
Fire hazard safety testing for electrical and electronic products, household appliances, and insulation materials. It is used to determine material ignition temperature and flammability index for product safety certification.
| Control & Display | Integrated PLC & 7" color touch screen |
|---|---|
| Glowing Element | Φ4 mm ± 0.04 mm Ni/Cr (77/20) special standard ring shape, horizontal standing |
| Thermocouple | 1 mm imported K thermocouple (Brand: American B+B); armour temperature resistance 1100°C (better than the standard of 1050°C) |
| Temperature Precision | 500°C–750°C +10%, 750°C–960°C +10%; temperature fluctuation < 3°C |
| Temperature Sensing Delay | 1.7 s |
| Thermostat | 12 bit A/D ±0.05% |
| Specimen Pressure on Glowing Filament | 0.95 N ± 0.1 N (adjustable) |
| Maximum Depth of Heating | 7 mm ± 0.5 mm |
| Specimen Movement Speed | Approx. 13 mm/s |
| Testing Time | 30 s ± 0.1 s (1 s – 999.9 s can be preset) |
| Thickness of Ignite Bedding Board | Thickness 10 mm, white pine board cover, 12 g/m² – 30 g/m² standard silk paper |
| Volume of Test Site | ≥ 0.5 m³, black background, background illuminance ≤ 20 Lx |
| Dimension and Weight | W: 1130 mm × D: 600 mm × H: 1400 mm, gas vent: 100 mm, 115 KGS |
| Power | Single phase AC 220 V ±10% / 50 Hz |
| Standard | IEC 60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC 60695-2-13, UL 746A, IEC 60335, IEC 60598, etc. |