logo
Products
PRODUCTS DETAILS
Home > Products >
IEC 62196-1 Resistive Inductive Three-Phase Power Load Cabinet Test Voltage AC100~600V

IEC 62196-1 Resistive Inductive Three-Phase Power Load Cabinet Test Voltage AC100~600V

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 5 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2117C-100
Test Voltage:
AC100~600V
Test Current:
8-100A
Power Factor:
0.3~0.99
Output Power Capacity:
120kVA
Display Accuracy:
±0.5 Class
Output Method:
Resistive + Inductive
Control Method:
Button Control
Test Station:
Single Station
Highlight:

IEC 62196-1 power load cabinet

,

three-phase resistive inductive load cabinet

,

AC100-600V vehicle testing equipment

Product Description
Product Overview

The Sinuo Three-Phase AC Resistive and Inductive Load Bank is designed for electrical performance evaluation, switching endurance testing, and load simulation of electrical accessories and related equipment. It supports test applications associated with IEC 62196-1:2026 Clauses 22 and 23, IEC 61535 Clause 17, and other applicable test requirements.

This three-phase AC load cabinet combines adjustable resistive and inductive loads, allowing users to configure load conditions for different electrical testing procedures. With an adjustable test voltage of 100–600V AC, a current range of 8–100A, and a continuously adjustable power factor from 0.3 to 0.99, the system provides flexible load configuration for laboratory testing.

The equipment can be used for switch endurance and electrical performance tests involving appliance switches, plugs, socket-outlets, transformers, fuses, and other compatible electrical products. Its integrated chamber-type construction, forced-air cooling, panel-operated load switching, and multiple electrical protection functions make it suitable for indoor electrical safety and product verification laboratories.

Key Features and Benefits
  • Wide-range three-phase AC output: Adjustable test voltage from 100V to 600V AC for different electrical load testing requirements.
  • Combined resistive and inductive loading: Configure resistive loads and inductive loads according to the intended test procedure.
  • Adjustable power factor: Continuous adjustment from 0.3 to 0.99 supports testing under different load conditions.
  • Fine current adjustment: Current adjustment resolution of 0.1A, with automatic output cut-off when the current exceeds 105A.
  • Digital measurement display: Three-phase voltage and current readings, together with digital power factor indication, support convenient monitoring during testing.
  • Integrated safety protection: Leakage, overheating, overcurrent, overload, and short-circuit protection functions.
  • Forced-air cooling: Built-in fan-assisted cooling for indoor laboratory operation.
  • Practical laboratory installation: Chamber-type construction with casters for easier positioning and movement.

IEC 62196-1 Resistive Inductive Three-Phase Power Load Cabinet Test Voltage AC100~600V

Technical Specifications

The following table summarizes the main specifications of the three-phase load bank for technical evaluation and procurement reference.

Parameter Specification
Product type Three-phase AC resistive and inductive load bank
Applicable standards IEC 62196-1:2026 Clauses 22 and 23; IEC 61535 Clause 17; other applicable requirements
Rated output capacity 120kVA, three-phase
Test voltage AC 100–600V, steplessly adjustable
Maximum load voltage 600V AC
Test frequency 50Hz / 60Hz
Test current range 8–100A, adjustable
Current adjustment resolution 0.1A
Overcurrent cut-off Automatic output cut-off above 105A
Power factor 0.3–0.99, continuously adjustable
Voltage display Digital, three-phase voltage indication, accuracy class 0.5
Current display Digital, accuracy class 0.5
Power factor display Digital, resolution 0.001
Load configuration Resistive and inductive
Resistive load element Constantan wire winding
Inductive load element Iron-core inductors / reactors
Load components Three-phase resistors, reactors, and capacitors, as configured
Load switching Panel-mounted knife switches
Control method Push-button control
Test stations 1 station
Cooling method Forced-air cooling with built-in fan
Protection functions Leakage, overheating, overcurrent, overload, and short-circuit protection
Instrument control power supply Single-phase AC 220V ±10%, 50Hz, with protective earth
Product test power supply Three-phase 380V, 50Hz
Approximate dimensions (H × W × D) 2000 × 1200 × 1200mm
Approximate weight 1400kg
Installation type Indoor
Load structure Chamber type
Ambient temperature 0°C to 40°C
Relative humidity Maximum 95%, non-condensing
Altitude Not exceeding 1000m
Environmental restrictions No corrosive gases or vapors
Mobility Equipped with casters
Applications of the Three-Phase Load Cabinet

This programmable-by-configuration resistive and inductive load system is intended for laboratory applications where controlled electrical loads are required. Actual load settings and test procedures should follow the relevant product standard and test plan.

1. EV Charging Connector and Coupler Testing

For laboratories working with IEC 62196-1 requirements, the load bank can provide resistive and inductive load conditions for applicable electrical testing of charging accessories. The intended application includes the relevant test procedures associated with Clauses 22 and 23.

2. Switch Endurance and Electrical Performance Testing

The adjustable load configuration can support applicable switching endurance and electrical performance evaluations of appliance switches and similar switching components under specified test conditions.

3. Plugs and Socket-Outlets

The three-phase load cabinet can be incorporated into suitable test setups for plugs, socket-outlets, and related electrical accessories, subject to their rated values and the requirements of the applicable standard.

4. Transformers, Fuses, and Other Electrical Components

The resistive and inductive load functions can also be used in compatible test arrangements for transformers, fuses, and other electrical products that require controlled load conditions.

Load Configuration and Operating Principle

The load cabinet uses groups of resistors and iron-core inductors to establish the required load configuration. Resistive elements are constructed using constantan wire windings, selected for their low temperature coefficient of resistance. Inductive elements can be connected or disconnected as required by the intended test setup.

Operators control the load through push buttons and panel-mounted knife switches. Digital instruments display the relevant three-phase voltage, current, and power factor readings. A built-in forced-air cooling system helps manage heat generated during load operation.

The equipment also incorporates protective functions against leakage, overheating, excessive current, overload, and short circuits. These functions help protect the test system during operation but do not replace appropriate laboratory electrical safety procedures.

Note: Protective functions are intended to safeguard the test system during operation and do not replace standard laboratory electrical safety procedures.

IEC 62196-1 Resistive Inductive Three-Phase Power Load Cabinet Test Voltage AC100~600V

Products
PRODUCTS DETAILS
IEC 62196-1 Resistive Inductive Three-Phase Power Load Cabinet Test Voltage AC100~600V
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 5 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2117C-100
Test Voltage:
AC100~600V
Test Current:
8-100A
Power Factor:
0.3~0.99
Output Power Capacity:
120kVA
Display Accuracy:
±0.5 Class
Output Method:
Resistive + Inductive
Control Method:
Button Control
Test Station:
Single Station
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
5 Sets Per Month
Highlight

IEC 62196-1 power load cabinet

,

three-phase resistive inductive load cabinet

,

AC100-600V vehicle testing equipment

Product Description
Product Overview

The Sinuo Three-Phase AC Resistive and Inductive Load Bank is designed for electrical performance evaluation, switching endurance testing, and load simulation of electrical accessories and related equipment. It supports test applications associated with IEC 62196-1:2026 Clauses 22 and 23, IEC 61535 Clause 17, and other applicable test requirements.

This three-phase AC load cabinet combines adjustable resistive and inductive loads, allowing users to configure load conditions for different electrical testing procedures. With an adjustable test voltage of 100–600V AC, a current range of 8–100A, and a continuously adjustable power factor from 0.3 to 0.99, the system provides flexible load configuration for laboratory testing.

The equipment can be used for switch endurance and electrical performance tests involving appliance switches, plugs, socket-outlets, transformers, fuses, and other compatible electrical products. Its integrated chamber-type construction, forced-air cooling, panel-operated load switching, and multiple electrical protection functions make it suitable for indoor electrical safety and product verification laboratories.

Key Features and Benefits
  • Wide-range three-phase AC output: Adjustable test voltage from 100V to 600V AC for different electrical load testing requirements.
  • Combined resistive and inductive loading: Configure resistive loads and inductive loads according to the intended test procedure.
  • Adjustable power factor: Continuous adjustment from 0.3 to 0.99 supports testing under different load conditions.
  • Fine current adjustment: Current adjustment resolution of 0.1A, with automatic output cut-off when the current exceeds 105A.
  • Digital measurement display: Three-phase voltage and current readings, together with digital power factor indication, support convenient monitoring during testing.
  • Integrated safety protection: Leakage, overheating, overcurrent, overload, and short-circuit protection functions.
  • Forced-air cooling: Built-in fan-assisted cooling for indoor laboratory operation.
  • Practical laboratory installation: Chamber-type construction with casters for easier positioning and movement.

IEC 62196-1 Resistive Inductive Three-Phase Power Load Cabinet Test Voltage AC100~600V

Technical Specifications

The following table summarizes the main specifications of the three-phase load bank for technical evaluation and procurement reference.

Parameter Specification
Product type Three-phase AC resistive and inductive load bank
Applicable standards IEC 62196-1:2026 Clauses 22 and 23; IEC 61535 Clause 17; other applicable requirements
Rated output capacity 120kVA, three-phase
Test voltage AC 100–600V, steplessly adjustable
Maximum load voltage 600V AC
Test frequency 50Hz / 60Hz
Test current range 8–100A, adjustable
Current adjustment resolution 0.1A
Overcurrent cut-off Automatic output cut-off above 105A
Power factor 0.3–0.99, continuously adjustable
Voltage display Digital, three-phase voltage indication, accuracy class 0.5
Current display Digital, accuracy class 0.5
Power factor display Digital, resolution 0.001
Load configuration Resistive and inductive
Resistive load element Constantan wire winding
Inductive load element Iron-core inductors / reactors
Load components Three-phase resistors, reactors, and capacitors, as configured
Load switching Panel-mounted knife switches
Control method Push-button control
Test stations 1 station
Cooling method Forced-air cooling with built-in fan
Protection functions Leakage, overheating, overcurrent, overload, and short-circuit protection
Instrument control power supply Single-phase AC 220V ±10%, 50Hz, with protective earth
Product test power supply Three-phase 380V, 50Hz
Approximate dimensions (H × W × D) 2000 × 1200 × 1200mm
Approximate weight 1400kg
Installation type Indoor
Load structure Chamber type
Ambient temperature 0°C to 40°C
Relative humidity Maximum 95%, non-condensing
Altitude Not exceeding 1000m
Environmental restrictions No corrosive gases or vapors
Mobility Equipped with casters
Applications of the Three-Phase Load Cabinet

This programmable-by-configuration resistive and inductive load system is intended for laboratory applications where controlled electrical loads are required. Actual load settings and test procedures should follow the relevant product standard and test plan.

1. EV Charging Connector and Coupler Testing

For laboratories working with IEC 62196-1 requirements, the load bank can provide resistive and inductive load conditions for applicable electrical testing of charging accessories. The intended application includes the relevant test procedures associated with Clauses 22 and 23.

2. Switch Endurance and Electrical Performance Testing

The adjustable load configuration can support applicable switching endurance and electrical performance evaluations of appliance switches and similar switching components under specified test conditions.

3. Plugs and Socket-Outlets

The three-phase load cabinet can be incorporated into suitable test setups for plugs, socket-outlets, and related electrical accessories, subject to their rated values and the requirements of the applicable standard.

4. Transformers, Fuses, and Other Electrical Components

The resistive and inductive load functions can also be used in compatible test arrangements for transformers, fuses, and other electrical products that require controlled load conditions.

Load Configuration and Operating Principle

The load cabinet uses groups of resistors and iron-core inductors to establish the required load configuration. Resistive elements are constructed using constantan wire windings, selected for their low temperature coefficient of resistance. Inductive elements can be connected or disconnected as required by the intended test setup.

Operators control the load through push buttons and panel-mounted knife switches. Digital instruments display the relevant three-phase voltage, current, and power factor readings. A built-in forced-air cooling system helps manage heat generated during load operation.

The equipment also incorporates protective functions against leakage, overheating, excessive current, overload, and short circuits. These functions help protect the test system during operation but do not replace appropriate laboratory electrical safety procedures.

Note: Protective functions are intended to safeguard the test system during operation and do not replace standard laboratory electrical safety procedures.

IEC 62196-1 Resistive Inductive Three-Phase Power Load Cabinet Test Voltage AC100~600V

sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2026 Sinuo Testing Equipment Co. , Limited . All Rights Reserved.