Send Message
products
PRODUCTS DETAILS
Home > Products >
IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 5 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN3311
Air Volume:
0~50 M³/min
Static Pressure:
0~2000 Pa
Voltage:
0~300V
Current:
0~20A
Power:
0~5000W
Speed:
0-5000 RPM
Temperature:
-20~80°C
Humidity:
0~100%
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
5 Sets Per Month
Highlight:

IEC 61591 Cooking Fume Extractor

,

Performance Measurement Cooking Fume Extractor

Product Description

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance

 

Product information:

 

This test system meets the air performance test requirements of IEC 61591:2019 clause 10, AMCA 210-07, ISO5801, etc.

It is customized according to the form, material, and maximum shape of the user’s specimens, used to simulate the maximum full pressure efficiency, working air volume, maximum air volume and maximum static pressure of the specimens under specific environmental conditions, to verify whether the specimens meets the limit values ​​required by the standard. It is suitable for air performance testing of range hoods and other cooking fume extractors with a rated voltage not exceeding 250V.

 

The test system adopts intelligent industrial control, large-size computer display and operation, automatic measurement. It can record and automatically print of test reports, and can analyze test results and test data.

 

The test system can measure and draw the corresponding curves of static pressure and air volume, air volume and speed, current, power, efficiency, etc. The specimens can also be tested in two states: inhalation and extraction, and the test performance meets the latest standards for relevant products.

 

Test principle and layout:

 

This solution adopts the blowing test mode, and controls the air volume by stepless adjusting the frequency of the auxiliary fan through the frequency converter; the middle of the air chamber is composed of a flow equalizing orifice plates, nozzles, starting actuators and nozzle plates; the chamber interface size is 600mm×600mm. This system automatically calculates the fan air volume by measuring the pressure difference before and after the nozzle. When the equipment is running, the air performance test device is run on, the air volume of the auxiliary fan is controlled by controlling the opening and closing combination of the nozzles and the current frequency of the frequency conversion device. The static pressure under the corresponding air volume is measured by a high precision micromanometer, so as to obtain the corresponding data of the air volume and air pressure of the specimen, and draw the air volume and air pressure curve. The system is compatible with the air performance test of two types of range hoods: external exhaust type A and suction type B.

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 0

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 1

 

Technical Parameters:

 

Table 1
Item Unit Scope Accuracy Other
Air volume (flow rate) m³/min 0~50 ±2%  
Static pressure/differential pressure

 

Pa

 

0~2000

Full scale ±0.055% Response time does not exceed 90ms

 

Voltage

 

V

 

0~300V

±(0.15% of reading + 0.35% of range) 10Hz≤f<440Hz

 

Current

 

A

0~5mA 0~20A ±(0.15% of reading + 0.35% of range) 10Hz≤f<440Hz
Power W 0~5000W

±(0.15% of reading + 0.50% of range)

±(0.25% of reading + 0.50% of range)

10Hz≤f<45Hz

 

45Hz≤f<440Hz

 

Temperature

 

°C

 

-20~80

±0.2°C

With a temperature gauge with a display accuracy of at least 0.1°C
Humidity % 0~100 ±3%RH Humidity meter with 0.1%RH
Atmospheric pressure kPa 0-200 ≦±200Pa Barometric pressure sensor
Speed ​​(standard configuration)

 

RPM

 

0-5000

 

±5 RPM

Measuring distance 5~100 cm

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 2

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 3

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 4

products
PRODUCTS DETAILS
IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 5 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN3311
Air Volume:
0~50 M³/min
Static Pressure:
0~2000 Pa
Voltage:
0~300V
Current:
0~20A
Power:
0~5000W
Speed:
0-5000 RPM
Temperature:
-20~80°C
Humidity:
0~100%
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
5 Sets Per Month
Highlight

IEC 61591 Cooking Fume Extractor

,

Performance Measurement Cooking Fume Extractor

Product Description

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance

 

Product information:

 

This test system meets the air performance test requirements of IEC 61591:2019 clause 10, AMCA 210-07, ISO5801, etc.

It is customized according to the form, material, and maximum shape of the user’s specimens, used to simulate the maximum full pressure efficiency, working air volume, maximum air volume and maximum static pressure of the specimens under specific environmental conditions, to verify whether the specimens meets the limit values ​​required by the standard. It is suitable for air performance testing of range hoods and other cooking fume extractors with a rated voltage not exceeding 250V.

 

The test system adopts intelligent industrial control, large-size computer display and operation, automatic measurement. It can record and automatically print of test reports, and can analyze test results and test data.

 

The test system can measure and draw the corresponding curves of static pressure and air volume, air volume and speed, current, power, efficiency, etc. The specimens can also be tested in two states: inhalation and extraction, and the test performance meets the latest standards for relevant products.

 

Test principle and layout:

 

This solution adopts the blowing test mode, and controls the air volume by stepless adjusting the frequency of the auxiliary fan through the frequency converter; the middle of the air chamber is composed of a flow equalizing orifice plates, nozzles, starting actuators and nozzle plates; the chamber interface size is 600mm×600mm. This system automatically calculates the fan air volume by measuring the pressure difference before and after the nozzle. When the equipment is running, the air performance test device is run on, the air volume of the auxiliary fan is controlled by controlling the opening and closing combination of the nozzles and the current frequency of the frequency conversion device. The static pressure under the corresponding air volume is measured by a high precision micromanometer, so as to obtain the corresponding data of the air volume and air pressure of the specimen, and draw the air volume and air pressure curve. The system is compatible with the air performance test of two types of range hoods: external exhaust type A and suction type B.

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 0

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 1

 

Technical Parameters:

 

Table 1
Item Unit Scope Accuracy Other
Air volume (flow rate) m³/min 0~50 ±2%  
Static pressure/differential pressure

 

Pa

 

0~2000

Full scale ±0.055% Response time does not exceed 90ms

 

Voltage

 

V

 

0~300V

±(0.15% of reading + 0.35% of range) 10Hz≤f<440Hz

 

Current

 

A

0~5mA 0~20A ±(0.15% of reading + 0.35% of range) 10Hz≤f<440Hz
Power W 0~5000W

±(0.15% of reading + 0.50% of range)

±(0.25% of reading + 0.50% of range)

10Hz≤f<45Hz

 

45Hz≤f<440Hz

 

Temperature

 

°C

 

-20~80

±0.2°C

With a temperature gauge with a display accuracy of at least 0.1°C
Humidity % 0~100 ±3%RH Humidity meter with 0.1%RH
Atmospheric pressure kPa 0-200 ≦±200Pa Barometric pressure sensor
Speed ​​(standard configuration)

 

RPM

 

0-5000

 

±5 RPM

Measuring distance 5~100 cm

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 2

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 3

 

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 4

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.