Send Message
Home ProductsVehicle Testing Equipment

IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C

Certification
China Sinuo Testing Equipment Co. , Limited certification
China Sinuo Testing Equipment Co. , Limited certification
Customer Reviews
Perfect on-site installation service, excellent training and technology support. Absolutely helps us a lot.

—— Aryan Das

Thanks. Your company is very professional, I am sure we will have good cooperation in the future.

—— Fernando Fuentealba

It's a great purchase, good products received with good packing, will back to you for next needs.

—— Sarah Rashad

I'm Online Chat Now

IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C

IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C
IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C

Large Image :  IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C

Product Details:
Place of Origin: China
Brand Name: Sinuo
Certification: Calibration Certificate(cost additional )
Model Number: SN887-150L
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Standard Exporting Plywood Case
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 10 Sets / Month
Detailed Product Description
Applied Standard: IEC 62196-1 2020 Applied Clause: Clause 34.3
Chamber Inner Size: WHD=600×500×500mm Temperature Shock Range: -40~150℃
High Temperature Setting: +60℃ ~ +150℃ Low Temperature Setting: -40℃ ~ -10℃
Temperature Recovery Time: -40~150℃ About 3min Conversion Time: ≤8S
High Light:

IEC 62196-1 thermal shock test chamber

,

8S Cycling Test Chamber

 

IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber

 

IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C to 125°C

 

Product information:

 

This thermal shock test chamber is required by IEC 60068-2-14 (Test Na) and it is required by IEC 62196-1Ed.4CDV 2020 clause 34.3.

The hot and cold impact (thermal shock) test chamber is used to test whether the rapid changes in high and low temperatures cause adverse effects on the product. It is a necessary test equipment for the metal, plastic, rubber, electrical and electronic, automotive parts and other materials industries.

 

Structure:

 

1. Chamber structure: Built-in a high-temperature zone, a low-temperature zone, air valve, loop air duct and stainless steel loop fan, the test article is sent to the heat and cold zone by switching the basket; so as to achieve rapid temperature change and uniform distribution of indoor temperature

2. Inner chamber material: stainless steel

3. Outer chamber material: stainless steel

4. Insulation material: 24k glass wool for high temperature tank

5. Heater: Bare wire heater

6. Air supply circulation system: a. TECO motor b. Stainless steel extended shaft c. Multi-wing fan blade (SIROCCO FAN)

7.Chamber door: Monolithic door a. Flat embedded handle b. Rear button: SUS 304# c. Silicone foam tape

 

Technical parameters:

 

1. Inner chamber size: 600×500×500mm (W*H*D), can be customized

2. External chamber size: about 1400×2200×2200mm (W*H*D), according to final design

3. Temperature shock range: -40~150℃

4. High temperature setting: +60℃ ~ +150℃

5. Low temperature setting: -40℃ ~ -10℃

6. Temperature recovery time: -40~150℃ about 3min

7. Conversion time: ≤8S

8. Temperature exposure duration: more than 30min

9. Temperature setting range of high temperature zone: +60℃~+200℃

10. Temperature setting range of low temperature zone: -50℃ ~ -10℃

11. Temperature fluctuation in the sample area: ±1℃ (at constant temperature)

12. Temperature deviation: ±2℃ (no load, at constant state)

13. Temperature accuracy range: setting accuracy: ±0.1℃, indication accuracy: ±0.1℃, resolution: ±0.1℃

14. Test hole: one ψ50mm hole on the left side of the body, and one silicone plug.

15. Sample rack: stainless steel SUS 304# storage tray 2 pieces

16. Compressed air source: Operator should provide with compressed passenger air source above 5kg/cm2

17. Safety device: over-temperature protection, motor overload protection, compressor high-voltage protection switch, compressor overheat protection switch, compressor overcurrent protection, overvoltage under-phase reverse protection switch, leakage circuit breaker, cooling water abnormal protection

18. Equipment power supply conditions: voltage: 380V AC (±10%), with protective ground wire, grounding resistance ≤4Ω; Frequency: 60±0.5Hz

The user is required to configure the device with an air or power switch of corresponding capacity at the installation site, and this switch must be used independently for this device; power: 32kw; maximum current: 80A

 

Main configuration list:

 

No.: Name Brand
1 Refrigeration Compressor German Bock semi-compact compressor or German Bitzer semi-compact compressor
2 Oil separator Emerson
3 Plate heat exchanger Germany GEA
4 Pressure Switch DANFOSS
5 Condenser Made in China
6 Evaporator Made in China
7 Dry Filter DANFOSS
8 Capillary Sinuo
9 Expansion valve DANFOSS
10 Electromagnetic valve Castel DANFOSS
11 Controller Sinuo
12 Breaker Schneider
13 AC contactor Schneider
14 Thermal relay Schneider
15 Phase sequence relay Swiss Carlogavazzi
16 Relay Omron Japan
17 AC relay Schneider
18 Switching power supply Schneider
 

Sinuo can customize various of enviromental test chambers with different test volume, temperature range, accuracy,etc, based on different standards requirements. Welcome to contact us for more details.

 

IEC 62196-1 Vehicle Plugs Connectors Thermal Cycling Test Chamber -40°C To 125°C 0

 

 

Contact Details
Sinuo Testing Equipment Co. , Limited

Contact Person: Ms. Zoe Zou

Tel: +86 13527656435

Fax: 86-020-39185976

Send your inquiry directly to us (0 / 3000)