IEC 60898-1 960°C Abnormal Heat Glow Wire Test Apparatus For RCBO
Standards & Clauses:
This device is manufactured according to the standard of IEC 60898-1:2015 clause 9.15, IEC60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC60695-2-13, it is required by IEC 60335 clause 30, UL746A, etc.
Product Information:
This device simulates the thermal stress test of glowing component or heat source like overload resistance or ignition source which is caused in s short time. It is suitable for electric and electronic products, household appliances and other material to do fire hazard testing. It is also used in the No flame ignition source fire test to test initiation temperature and flammability index of related glowing filament.
This instrument adopts a new design concept and uses an advanced digital stepping motor to achieve precise positioning, and at the same time, realize rapid adjustment after specimen replacement, which truly meets the requirements of simple and convenient operation. The control system adopts PLC control, each parameter can reflect the real situation of relevant parameters, which is more real-time and accurately, and the operation is intuitive and convenient, meeting the needs of scientific research, far exceeding similar products.
Technical Parameters:
Control & Display | Integrated PLC & 7” color touch screen |
Glowing Element |
Ф4mm ± 0.04mm Ni/Cr (77/20) special standard ring shape, horizontal standing |
Thermocouple |
1mm import K thermocouple (Brand: American B+B), the temperature resistance of armour is 1100 ℃ (better than the standard of 1050 ℃) |
Temperature Precision |
500°C-750°C+10%, 750°C-960°C+10% Temperature fluctuation < 3 ℃ |
Temperature sensing delay | 1.7S |
Thermostat | 12 bit A/D ±0.05% |
Specimen pressure on glowing filament |
0.95N±0.1N (adjustable) |
Maximum depth of heating | 7mm ± 0.5mm |
Specimen movement speed | Approx. 13mm/S |
Testing time | 30s±0.1s (1s ~ 999.9s can be preset) |
Thickness of ignite bedding board |
12g /m 2 ~ 30g /m 2 standard silk paper Thickness 10mm, white pine board cover |
Volume of test site | ≥ 0.5m³, black background, background illuminance ≤ 20Lx |
Dimension and weight |
W: 1130mm × D: 600mm × H: 1400mm, gas vent:100mm, 115KGS |
Power | Single phase AC 220V±10% / 50Hz |
Standard | IEC60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC60695-2-13, UL746A, IEC 60335, IEC 60598, etc. |
![]() |
MOQ: | 1 |
Price: | Customized |
Standard Packaging: | Plywood |
Delivery Period: | 30 Days |
Payment Method: | L/C, , T/T, Western Union, MoneyGram |
Supply Capacity: | 1 set per month |
IEC 60898-1 960°C Abnormal Heat Glow Wire Test Apparatus For RCBO
Standards & Clauses:
This device is manufactured according to the standard of IEC 60898-1:2015 clause 9.15, IEC60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC60695-2-13, it is required by IEC 60335 clause 30, UL746A, etc.
Product Information:
This device simulates the thermal stress test of glowing component or heat source like overload resistance or ignition source which is caused in s short time. It is suitable for electric and electronic products, household appliances and other material to do fire hazard testing. It is also used in the No flame ignition source fire test to test initiation temperature and flammability index of related glowing filament.
This instrument adopts a new design concept and uses an advanced digital stepping motor to achieve precise positioning, and at the same time, realize rapid adjustment after specimen replacement, which truly meets the requirements of simple and convenient operation. The control system adopts PLC control, each parameter can reflect the real situation of relevant parameters, which is more real-time and accurately, and the operation is intuitive and convenient, meeting the needs of scientific research, far exceeding similar products.
Technical Parameters:
Control & Display | Integrated PLC & 7” color touch screen |
Glowing Element |
Ф4mm ± 0.04mm Ni/Cr (77/20) special standard ring shape, horizontal standing |
Thermocouple |
1mm import K thermocouple (Brand: American B+B), the temperature resistance of armour is 1100 ℃ (better than the standard of 1050 ℃) |
Temperature Precision |
500°C-750°C+10%, 750°C-960°C+10% Temperature fluctuation < 3 ℃ |
Temperature sensing delay | 1.7S |
Thermostat | 12 bit A/D ±0.05% |
Specimen pressure on glowing filament |
0.95N±0.1N (adjustable) |
Maximum depth of heating | 7mm ± 0.5mm |
Specimen movement speed | Approx. 13mm/S |
Testing time | 30s±0.1s (1s ~ 999.9s can be preset) |
Thickness of ignite bedding board |
12g /m 2 ~ 30g /m 2 standard silk paper Thickness 10mm, white pine board cover |
Volume of test site | ≥ 0.5m³, black background, background illuminance ≤ 20Lx |
Dimension and weight |
W: 1130mm × D: 600mm × H: 1400mm, gas vent:100mm, 115KGS |
Power | Single phase AC 220V±10% / 50Hz |
Standard | IEC60695-2-10, IEC 60695-2-11, IEC 60695-2-12, IEC60695-2-13, UL746A, IEC 60335, IEC 60598, etc. |