This is a general-purpose electrodynamic vibration test system built for product reliability validation and environmental stress screening (ESS). It is widely used by battery manufacturers, electronics makers, power tool companies, third-party testing laboratories and research institutes.
The system handles a broad range of specimens, from small electronic assemblies to complete battery packs. It is not tied to one single industry. For battery users, it reproduces the real vibration stress that cells, modules and packs encounter during road transport, vehicle operation, storage and handling. This helps engineers expose latent defects at an early development stage, validate structural strength, run fatigue life assessment and screen out non-conforming products on mass production lines.
It covers diversified battery chemistries: lithium-ion, nickel-metal hydride, nickel-cadmium and lead-acid batteries, as well as portable power banks. The system can be integrated with an environmental test chamber to build an all-in-one temperature-humidity-vibration combined test station, a preferred setup for compliance testing under UN38.3, IEC 62660, ISO 16750 and other global regulations.
One platform, three test capabilities. Sine sweep, random vibration and classical shock are switched by the VENZO-820 controller; no extra shaker hardware is needed. The same bench also serves automotive electronics, power tools, precision instruments and general industrial products.
![]()
All three can damage a product, yet they apply completely different mechanical excitation. Choosing the wrong one is like checking a fall with a fatigue run: both look intense, but they evaluate different capabilities.
Sine vibration excites only one dominant frequency at any moment. A sweep test moves the frequency gradually from low to high (or the reverse), like a searchlight scanning across the full frequency range of your sample.
What hidden structural risks can sine vibration reveal? When the sweep approaches the natural frequency of the assembly, resonance occurs and the structural response is greatly amplified. Loose screws, cracked brackets and connector contact failures are typical failure modes found in sine sweep tests.
Key parameters: frequency range, displacement or acceleration, sweep rate, cycle count and dwell time. Low-frequency testing is usually limited by displacement; high-frequency testing depends more on acceleration, thrust and dynamic fixture performance.
Common standards: GB/T 2423.10, IEC 60068-2-6.
Random vibration superimposes countless frequency components simultaneously, with unpredictable instantaneous amplitude. It closely replicates real excitation from road transport, airborne operation and engine broadband vibration.
Think of many people pushing one swing at different rhythms at the same time: instead of a single-frequency sweep, the sample receives continuous broadband energy input.
What do PSD and gRMS mean? Random specifications are defined by PSD (Power Spectral Density), which describes energy distribution per frequency bandwidth. The overall gRMS value is the integral of the full PSD curve.
Please note: equal gRMS does not mean identical severity. If the energy concentrates in different frequency bands, the modal response differs and the failure locations can be completely different.
Common standards: GB/T 2423.56, IEC 60068-2-34, GJB 150.16A.
Shock test applies a high-magnitude mechanical pulse in an extremely short window, simulating transient events such as drop, collision, loading impact, ejection or landing.
Peak acceleration tells you how heavy the strike is; pulse width tells you how long the contact lasts; velocity change (the area under the acceleration-time curve) reflects the total momentum transferred.
Which classic waveforms can this system generate? Half-sine, trailing-edge sawtooth and trapezoidal pulses. For complex assemblies, SRS (Shock Response Spectrum) analysis is also available to calculate maximum structural response at different natural frequencies.
Common standards: GB/T 2423.5, IEC 60068-2-27, GJB 150.18A.
No. They are not interchangeable. Sine sweep excels at resonance searching but cannot reproduce a real broadband operating environment. Random vibration simulates continuous broadband excitation, yet a given gRMS level cannot represent a single high-peak shock pulse.
How to choose? Match the test to your product's real service lifecycle:
| Test Type | Main Evaluation Target | Typical Failure Modes | Best-fit Application |
| Sine Vibration | Resonance frequency, dynamic characteristics, single-frequency endurance | Screw loosening, bracket cracking, contact bounce, local response amplification | Resonance search, sweep inspection, fixed-frequency dwell endurance |
| Random Vibration | Function and fatigue under broadband environment | Solder joint fatigue, connector wear, harness damage, intermittent function failure | Road transport, vehicle operation, aerospace broadband vibration |
| Shock Test | Instant overload, structural strength, transient function | Fragile part rupture, residual stress, fastener detachment, internal collision | Drop, collision, handling impact, ejection and landing |
![]()
| Parameter Item | Specification |
| Sine Thrust | 20000N (2200kgf) |
| Random Thrust | 20000N (2200kgf) |
| Shock Thrust | 40000N (4400kgf) |
| Frequency Range | DC ~ 3000Hz |
| Continuous Displacement | 51mm |
| Max Shock Displacement | 51mm |
| Max Velocity | 2 m/s |
| Max Acceleration (No Load) | 981m/s² (100g) |
| Moving Coil Diameter | Φ320mm |
| 1st Order Resonance Frequency | 3200Hz ±5% |
| Allowable Eccentric Moment | ≤2500 N·cm |
| Equivalent Moving Mass | 20kg |
| Max Static Load | 400kg |
| Axial Isolation Frequency | <2.5Hz |
| Ambient Working Temperature | 0 ~ 40℃ |
| Amplifier Rated Output Power | 21kVA |
| Amplifier Efficiency | >90% |
| Signal-to-Noise Ratio | >65dB |
| MTBF | >3500h |
| Cooling Method | Forced air cooling |
| Power Supply | AC 3P 380V ±10%, 50Hz |
| Amplifier Protection | 18 modes: overvoltage, undervoltage, over-displacement, overheat, interlock, soft start, etc. |
| Item | Horizontal Slip Table SC-1010 | Vertical Extension Table TB-1010 |
| Table Dimension | 1000*1000mm (square) | 1000*1000mm (square) |
| Max Bearing Equivalent Mass | ~150kg | ~143kg |
| Upper Limit Frequency | Sine: 2000Hz / Random: 2000Hz | Sine: 800Hz / Random: 2000Hz |
| Table Material | Magnesium-aluminum alloy | Magnesium-aluminum alloy |
| Structure Feature | Oil film damping, high overturning resistance, granite base | Custom fixture available for irregular specimens |
| Parameter | Value |
| Fan Power | 7.5kW |
| Air Volume | 0.71m³/min |
| Air Duct Diameter | 200mm |
| Max Duct Length | 4.5m |
| Wind Pressure | 8800Pa |
| Net Weight | 200kg |
| Module | Key Performance |
| Sine Control | DC~20000Hz, linear/log sweep, sweep rate 0.1~10 oct/min, control precision ±0.5dB, waveform distortion ≤0.5% |
| Random Control | PSD spectrum control, accuracy ±1dB (90% confidence), control loop up to 2000Hz |
| Shock Control | Half-sine, triangle, sawtooth and square shock waveforms, 5~2000Hz shock spectrum synthesis |
| Data Acquisition Card USB01 | 16-bit, 400KS/s sampling rate, ±5V signal range, Win XP/2000, USB1.1 & 2.0 |
| Operation | Test recipe saving and repeat running, real-time curve display, report export and printing |
General vibration reliability and environmental stress screening for electronic and mechanical products. Lithium-ion, Ni-MH, Ni-Cd and lead-acid battery cell, module and pack testing. UN38.3 lithium battery transport vibration test. IEC 62660 power battery vibration reliability test (EV and energy storage battery as one application). ISO 16750 automotive electronics and battery environmental stress screening. Power bank and consumer lithium battery vibration fatigue and life assessment. Suitable for R&D laboratory, third-party testing laboratory, factory incoming and outgoing quality screening.
|
|
| MOQ: | 1 |
| Price: | Customized |
| Standard Packaging: | Plywood Case |
| Delivery Period: | 30 Working Days |
| Payment Method: | T/T |
| Supply Capacity: | 10 sets per month |
This is a general-purpose electrodynamic vibration test system built for product reliability validation and environmental stress screening (ESS). It is widely used by battery manufacturers, electronics makers, power tool companies, third-party testing laboratories and research institutes.
The system handles a broad range of specimens, from small electronic assemblies to complete battery packs. It is not tied to one single industry. For battery users, it reproduces the real vibration stress that cells, modules and packs encounter during road transport, vehicle operation, storage and handling. This helps engineers expose latent defects at an early development stage, validate structural strength, run fatigue life assessment and screen out non-conforming products on mass production lines.
It covers diversified battery chemistries: lithium-ion, nickel-metal hydride, nickel-cadmium and lead-acid batteries, as well as portable power banks. The system can be integrated with an environmental test chamber to build an all-in-one temperature-humidity-vibration combined test station, a preferred setup for compliance testing under UN38.3, IEC 62660, ISO 16750 and other global regulations.
One platform, three test capabilities. Sine sweep, random vibration and classical shock are switched by the VENZO-820 controller; no extra shaker hardware is needed. The same bench also serves automotive electronics, power tools, precision instruments and general industrial products.
![]()
All three can damage a product, yet they apply completely different mechanical excitation. Choosing the wrong one is like checking a fall with a fatigue run: both look intense, but they evaluate different capabilities.
Sine vibration excites only one dominant frequency at any moment. A sweep test moves the frequency gradually from low to high (or the reverse), like a searchlight scanning across the full frequency range of your sample.
What hidden structural risks can sine vibration reveal? When the sweep approaches the natural frequency of the assembly, resonance occurs and the structural response is greatly amplified. Loose screws, cracked brackets and connector contact failures are typical failure modes found in sine sweep tests.
Key parameters: frequency range, displacement or acceleration, sweep rate, cycle count and dwell time. Low-frequency testing is usually limited by displacement; high-frequency testing depends more on acceleration, thrust and dynamic fixture performance.
Common standards: GB/T 2423.10, IEC 60068-2-6.
Random vibration superimposes countless frequency components simultaneously, with unpredictable instantaneous amplitude. It closely replicates real excitation from road transport, airborne operation and engine broadband vibration.
Think of many people pushing one swing at different rhythms at the same time: instead of a single-frequency sweep, the sample receives continuous broadband energy input.
What do PSD and gRMS mean? Random specifications are defined by PSD (Power Spectral Density), which describes energy distribution per frequency bandwidth. The overall gRMS value is the integral of the full PSD curve.
Please note: equal gRMS does not mean identical severity. If the energy concentrates in different frequency bands, the modal response differs and the failure locations can be completely different.
Common standards: GB/T 2423.56, IEC 60068-2-34, GJB 150.16A.
Shock test applies a high-magnitude mechanical pulse in an extremely short window, simulating transient events such as drop, collision, loading impact, ejection or landing.
Peak acceleration tells you how heavy the strike is; pulse width tells you how long the contact lasts; velocity change (the area under the acceleration-time curve) reflects the total momentum transferred.
Which classic waveforms can this system generate? Half-sine, trailing-edge sawtooth and trapezoidal pulses. For complex assemblies, SRS (Shock Response Spectrum) analysis is also available to calculate maximum structural response at different natural frequencies.
Common standards: GB/T 2423.5, IEC 60068-2-27, GJB 150.18A.
No. They are not interchangeable. Sine sweep excels at resonance searching but cannot reproduce a real broadband operating environment. Random vibration simulates continuous broadband excitation, yet a given gRMS level cannot represent a single high-peak shock pulse.
How to choose? Match the test to your product's real service lifecycle:
| Test Type | Main Evaluation Target | Typical Failure Modes | Best-fit Application |
| Sine Vibration | Resonance frequency, dynamic characteristics, single-frequency endurance | Screw loosening, bracket cracking, contact bounce, local response amplification | Resonance search, sweep inspection, fixed-frequency dwell endurance |
| Random Vibration | Function and fatigue under broadband environment | Solder joint fatigue, connector wear, harness damage, intermittent function failure | Road transport, vehicle operation, aerospace broadband vibration |
| Shock Test | Instant overload, structural strength, transient function | Fragile part rupture, residual stress, fastener detachment, internal collision | Drop, collision, handling impact, ejection and landing |
![]()
| Parameter Item | Specification |
| Sine Thrust | 20000N (2200kgf) |
| Random Thrust | 20000N (2200kgf) |
| Shock Thrust | 40000N (4400kgf) |
| Frequency Range | DC ~ 3000Hz |
| Continuous Displacement | 51mm |
| Max Shock Displacement | 51mm |
| Max Velocity | 2 m/s |
| Max Acceleration (No Load) | 981m/s² (100g) |
| Moving Coil Diameter | Φ320mm |
| 1st Order Resonance Frequency | 3200Hz ±5% |
| Allowable Eccentric Moment | ≤2500 N·cm |
| Equivalent Moving Mass | 20kg |
| Max Static Load | 400kg |
| Axial Isolation Frequency | <2.5Hz |
| Ambient Working Temperature | 0 ~ 40℃ |
| Amplifier Rated Output Power | 21kVA |
| Amplifier Efficiency | >90% |
| Signal-to-Noise Ratio | >65dB |
| MTBF | >3500h |
| Cooling Method | Forced air cooling |
| Power Supply | AC 3P 380V ±10%, 50Hz |
| Amplifier Protection | 18 modes: overvoltage, undervoltage, over-displacement, overheat, interlock, soft start, etc. |
| Item | Horizontal Slip Table SC-1010 | Vertical Extension Table TB-1010 |
| Table Dimension | 1000*1000mm (square) | 1000*1000mm (square) |
| Max Bearing Equivalent Mass | ~150kg | ~143kg |
| Upper Limit Frequency | Sine: 2000Hz / Random: 2000Hz | Sine: 800Hz / Random: 2000Hz |
| Table Material | Magnesium-aluminum alloy | Magnesium-aluminum alloy |
| Structure Feature | Oil film damping, high overturning resistance, granite base | Custom fixture available for irregular specimens |
| Parameter | Value |
| Fan Power | 7.5kW |
| Air Volume | 0.71m³/min |
| Air Duct Diameter | 200mm |
| Max Duct Length | 4.5m |
| Wind Pressure | 8800Pa |
| Net Weight | 200kg |
| Module | Key Performance |
| Sine Control | DC~20000Hz, linear/log sweep, sweep rate 0.1~10 oct/min, control precision ±0.5dB, waveform distortion ≤0.5% |
| Random Control | PSD spectrum control, accuracy ±1dB (90% confidence), control loop up to 2000Hz |
| Shock Control | Half-sine, triangle, sawtooth and square shock waveforms, 5~2000Hz shock spectrum synthesis |
| Data Acquisition Card USB01 | 16-bit, 400KS/s sampling rate, ±5V signal range, Win XP/2000, USB1.1 & 2.0 |
| Operation | Test recipe saving and repeat running, real-time curve display, report export and printing |
General vibration reliability and environmental stress screening for electronic and mechanical products. Lithium-ion, Ni-MH, Ni-Cd and lead-acid battery cell, module and pack testing. UN38.3 lithium battery transport vibration test. IEC 62660 power battery vibration reliability test (EV and energy storage battery as one application). ISO 16750 automotive electronics and battery environmental stress screening. Power bank and consumer lithium battery vibration fatigue and life assessment. Suitable for R&D laboratory, third-party testing laboratory, factory incoming and outgoing quality screening.