Windproof Chamber For Lamps Product Temperature Measurement Customizable Size IEC 60598-1
Product overview:
This windproof chamber is designed according to standard IEC 60598-1:2017 Clause 12.4.1 and Annex D and etc. Applied to provide standard environment condition for lamps product temperature measurement.
The bottom surface is solid wood panels, the other sides are double-layer metal mesh plates, mesh plates spacing is 150mm, ventilation rate of about 40%; all the plates are black matt painted.
Technical parameters:
Outer size | 2100 x 2100 x 2168 mm (L x D x H) |
Inner size | 1800 x 1800 x 2000mm (L x D x H) |
Metal mesh plates space | 150mm |
Door structure | Single, double layer (outward open), 900mm x 1900mm (W*H) |
Aperture of screen | ф2mm |
Ventilation rate | Approx. 40.5% |
Surface coating | black matt paint |
Floor plate size | 2100mm x 2100mm x 18mm (L x D x Thickness) |
Temperature measuring device |
24 channels, measuring range: up to 260°C, measuring accuracy: ±(0.05% rdg. +0.5℃), display resolution: 0.01°C
|
Sample placement rack |
Aluminum profile structure (four stations)
|
Temperature sensing copper sheet + 3 meters thermocouple wire | 25 NOS |
Main configuration:
No.: | Name | Spec. | QTY |
1 | Outer enclosure | L2100mmXD2100mmXH2168mm | 1 Set |
2 | Inner enclosure | L1800mmXD1800mmXH2000mm | 1 Set |
3 | Swing door | W 900mmX H 1900mm (single fan, double layer) | 1 PC |
4 | Floor | L2100mmXD2100mmXH18mm | 1 Set |
5 | Sample rack | Aluminum profile structure (four stations) | 1 Set |
6 | Temperature sensing copper sheet + 3 meters thermocouple wire | 25 Nos | |
7 | Temperature measuring device | 24 channels | 1 Set |
Windshield installation requirements:
External requirements:
There is at least 300mm clearance around the top and sides of the draft shield.
The location of the windshield should be as far away as possible from the air flow and prevent sudden changes in air temperature and radiant heat of the light source.
Ambient temperature: about 25 ℃.
Internal sample installation requirements:
The gap between the inner surface of the draft shield and any part of the lamp should be at least 200mm.
When multiple lamps are tested at the same time, attention should be paid to use light barriers to prevent the radiant heat between lamps from affecting each other.
Different lamps are tested in the same state as they are in actual use as far as possible. This equipment has provided a variety of baffles that can be combined to facilitate various combinations.
|
MOQ: | 1 |
Price: | Customized |
Standard Packaging: | Plywood Case |
Delivery Period: | 30 Days |
Payment Method: | T/T |
Supply Capacity: | 20 sets per month |
Windproof Chamber For Lamps Product Temperature Measurement Customizable Size IEC 60598-1
Product overview:
This windproof chamber is designed according to standard IEC 60598-1:2017 Clause 12.4.1 and Annex D and etc. Applied to provide standard environment condition for lamps product temperature measurement.
The bottom surface is solid wood panels, the other sides are double-layer metal mesh plates, mesh plates spacing is 150mm, ventilation rate of about 40%; all the plates are black matt painted.
Technical parameters:
Outer size | 2100 x 2100 x 2168 mm (L x D x H) |
Inner size | 1800 x 1800 x 2000mm (L x D x H) |
Metal mesh plates space | 150mm |
Door structure | Single, double layer (outward open), 900mm x 1900mm (W*H) |
Aperture of screen | ф2mm |
Ventilation rate | Approx. 40.5% |
Surface coating | black matt paint |
Floor plate size | 2100mm x 2100mm x 18mm (L x D x Thickness) |
Temperature measuring device |
24 channels, measuring range: up to 260°C, measuring accuracy: ±(0.05% rdg. +0.5℃), display resolution: 0.01°C
|
Sample placement rack |
Aluminum profile structure (four stations)
|
Temperature sensing copper sheet + 3 meters thermocouple wire | 25 NOS |
Main configuration:
No.: | Name | Spec. | QTY |
1 | Outer enclosure | L2100mmXD2100mmXH2168mm | 1 Set |
2 | Inner enclosure | L1800mmXD1800mmXH2000mm | 1 Set |
3 | Swing door | W 900mmX H 1900mm (single fan, double layer) | 1 PC |
4 | Floor | L2100mmXD2100mmXH18mm | 1 Set |
5 | Sample rack | Aluminum profile structure (four stations) | 1 Set |
6 | Temperature sensing copper sheet + 3 meters thermocouple wire | 25 Nos | |
7 | Temperature measuring device | 24 channels | 1 Set |
Windshield installation requirements:
External requirements:
There is at least 300mm clearance around the top and sides of the draft shield.
The location of the windshield should be as far away as possible from the air flow and prevent sudden changes in air temperature and radiant heat of the light source.
Ambient temperature: about 25 ℃.
Internal sample installation requirements:
The gap between the inner surface of the draft shield and any part of the lamp should be at least 200mm.
When multiple lamps are tested at the same time, attention should be paid to use light barriers to prevent the radiant heat between lamps from affecting each other.
Different lamps are tested in the same state as they are in actual use as far as possible. This equipment has provided a variety of baffles that can be combined to facilitate various combinations.