Product Details:
Payment & Shipping Terms:
|
Sampling Unit Type: | Packed Column, Split | Flow Setting Range: | H20~200ml/min |
---|---|---|---|
Column Head Pressure Range: | 0~400kpa | Column Head Pressure Accuracy: | 0.1kpa |
Sampler Temperature Control Range: | RT+7℃~420℃ | Column Thermostat Inner Volume: | 225L |
Ignition Function: | Automatic | Simultaneous Installations: | Up To 2 |
Cooling Method: | Back Door | Heating Rate: | 0.1℃~60℃/min |
High Light: | 225L Oxide Residual Amounts Detector,Medical Mask Oxide Residual Amounts Detector,225L Medical Material Tester |
Programmable Medical Mask Ethylene Oxide Residual Amounts Detector 225L
Product overview:
The medical mask ethylene oxide detector adopts a 7-inch color touch screen, and the gas circuit adopts EPC (electronic pressure closed-loop control), EFC (electronic flow closed-loop control) technology, which can be adjusted arbitrarily within the setting range; one button starts automatically. It has functions of automatic heating, ignition, self-check, air leakage alarm, and can store and call various sample conditions; computer back control and host touch screen realize synchronous two-way control; with 8 external events extended function interface, optional Various control valves; the external link method is network port connection (RJ45).
The medical mask ethylene oxide detector is suitable for all disposable medical supplies that are sterilized by ethylene oxide sterilization equipment for the detection of ethylene oxide residual gas spectrometer. Such as disposable medical protective masks, disposable sterile syringes, disposable blood circuit products, disposable blood containers, disposable protective clothing, soft tissue expanders, medical surgical masks, medical absorbent cotton, implantable drug delivery devices, Medical infusion set, medical blood transfusion set, etc.
Technical parameters:
Column thermostat | Inner volume | 225L | |
Temperature control range | RT+5℃~400℃ | ||
Temperature control accuracy | ±0.1℃ | ||
Heating rate | 0.1℃~60℃/min | ||
Order of Program heating | 16 | ||
Repeatability of program heating | ≤2% | ||
Cooling method | Back door | ||
Cooling rate | Required time from 250℃~50℃ is ≤10min | ||
Sampler | Temperature control range | RT+7℃~420℃ | |
Temperature control method | Independent temperature control | ||
Carrier gas flow control method | Constant pressure | ||
Number of simultaneous installations | Up to 3 | ||
Sampling unit type | Packed column, split | ||
Split ratio | Split ratio display | ||
Column head pressure range | 0~400kpa | ||
Column head pressure control accuracy | 0.1kpa | ||
Flow setting range | H20~200ml/min N20~150ml/min | ||
Detector | Choose one between FID, TCD | ||
Temperature range | RT+7℃~420℃ | ||
Number of simultaneous installations | Up to 2 | ||
Ignition function | Automatic | ||
Hydrogen flame ionization detector (FID) |
Detection limit | ≤3*10-12g/s (N-hexadecane) | |
Baseline noise | ≤5*10-14A | ||
Baseline drift | ≤6*10-13A | ||
Dynamic Range | 107 | ||
RSD | ≤3% | ||
Thermal Conductivity Detector (TCD) | Sensitivity | 5000V.ml/mg (N-hexadecane) | |
Baseline noise | ≤0.05mV | ||
Baseline drift | ≤0.15mV/30min | ||
Dynamic Range | 105 | ||
Power supply | AC 220V/50Hz, or match client’s local power supply requirements | ||
Power | 3000W |
Technical advantages:
1. Flexible sampling system. In addition to the general sampling interface, the machine is also equipped with interface protocol docking, convenient installation of automatic sampler and valve center cutting.
2. Adopt high precision digital precision valve steady flow gas path, two-stage pressure steady flow method carrier gas, high precision digital precision diaphragm control valve.
3. Perfect gas pipeline and vacuum welding technology. The gas pipeline used in this instrument adopts no-cleaning high-brightness stainless steel pipeline, which really provides a dry and clean carrier for high-purity gas.
4. With low voltage carrier gas circuit and air cutting protection function.
5. The instrument has high temperature protection function. When any temperature control exceeds a certain range of set temperature, the instrument will stop operation and alarm.
6. The corresponding signal range is wide and the solvent peak is not flat. Meet high concentration and low concentration test. It has good consistency and can meet the needs of high purity sample analysis.
7. Unique operation control system software and hardware design, the instrument automatically realizes the whole software monitoring of the system in the operation process, fundamentally eliminates the phenomenon of temperature and operation parameters of the instrument out of control. Realize "no fault" overtemperature protection, unique active temperature protection function and double hardware self-locking overtemperature control structure, to ensure the safe operation of the instrument when unattended.
8. The signal output of the instrument can be easily connected with peripheral data processing equipment or plotting equipment, such as various chromatographic data processors and chromatographic workstations.
9. The standard configuration of the special network control version of the chromatography workstation, can set all the numerical parameters of the instrument, control the operation, to achieve two-way communication and two-way protection. According to the standard sample, it can directly detect and output the name and type of residual solvent in the analysis object (UG/G), which is convenient for testing personnel to consult the test label for data analysis.