UL 1581 Electrical Cables Wires 225W 500W Flame VW1 FT2 4m³ Flammability Test Chamber
Overview:
This flammability test chamber meets the requirements of UL1581 flame test. The effects of flames in the early stages of fire on electrical and electronic products are used to assess the degree of fire hazard through simulation techniques. It is mainly used for 1080 VW-1 (vertical-specimen) flame test and 1100 horizontal-specimen/ FT2 flame test on finished wires and cables or cords, to evaluate the ability of wires, cables or flexible cords to spread flame to nearby flammable materials when it is on fire.
The equipment adopts PLC control system, touch screen humanized operation interface, black background, multi-function flame gauge; the chamber body is made of stainless steel, the observation window is large; the original imported flame control system to make the flame adjustment become simple; and it has stable performance and convenient operation.
Techinicals:
Flames | 225W&500W |
Standard | UL1581 |
Power Supply | 220V/ 50Hz or 110V/60Hz (can be customized) |
Operation system | Mitsubishi PLC control, VEINVIEW7” touch screen |
Ignition Process | Automatic |
Burner | Diameter: 9.5mm ± 0.5mm, Length:100mm, Original imported, in line with ASTM 5025 standard |
Burning Angles | 0°, 20°, 45° adjustable |
Flame Height | 20mm~125mm±1mm adjustable |
Timing Device | 9999X0.1s can be preset |
Thermocouple | U.S. original Omega Φ0.5mm armored stainless steel sheathed K-type thermocouple |
Temperature Measurement Distance | 25±1mm/55±1mm |
Temperature Measurement Range | MAX 1100°C |
Flame Test |
Adopt original imported flowmeter, the flow rate is adjustable, the accuracy is 1%, the following are the reference values of each test: 500W: 965±30ml/min, 54±2S(100-700°) Reference values of UL1581 power, flame height, temperature measurement time and flow: 225W: (16.5mm)/84±2S 405 ±10mL/min& 45±5 mm water 500W: 125mm(40mm)/54±2S A: 965 ±30mL/min&125±25 mm water B: 385 ±15mL/min&552±100 mm water C: 300 ±10mL/ min&600±125 mm water |
Copper Weight |
Ф9mm±0.01mm Copper head,Cu-ETP purity:99.96%, 10 ± 0 .05 g |
Gas Category | Methane |
Test Space | 4m³ |
Chamber and Appearance | Stainless steel chamber, black matt background with exhaust fan |
Size and weight | W*D*H=1.7*1.3*2.4m, about 350kg |
MOQ: | 1 |
Price: | Negotiation |
Standard Packaging: | Plywood |
Delivery Period: | 1 Month |
Payment Method: | L/C, T/T, Western Union, MoneyGram |
Supply Capacity: | 20 Sets Per Month |
UL 1581 Electrical Cables Wires 225W 500W Flame VW1 FT2 4m³ Flammability Test Chamber
Overview:
This flammability test chamber meets the requirements of UL1581 flame test. The effects of flames in the early stages of fire on electrical and electronic products are used to assess the degree of fire hazard through simulation techniques. It is mainly used for 1080 VW-1 (vertical-specimen) flame test and 1100 horizontal-specimen/ FT2 flame test on finished wires and cables or cords, to evaluate the ability of wires, cables or flexible cords to spread flame to nearby flammable materials when it is on fire.
The equipment adopts PLC control system, touch screen humanized operation interface, black background, multi-function flame gauge; the chamber body is made of stainless steel, the observation window is large; the original imported flame control system to make the flame adjustment become simple; and it has stable performance and convenient operation.
Techinicals:
Flames | 225W&500W |
Standard | UL1581 |
Power Supply | 220V/ 50Hz or 110V/60Hz (can be customized) |
Operation system | Mitsubishi PLC control, VEINVIEW7” touch screen |
Ignition Process | Automatic |
Burner | Diameter: 9.5mm ± 0.5mm, Length:100mm, Original imported, in line with ASTM 5025 standard |
Burning Angles | 0°, 20°, 45° adjustable |
Flame Height | 20mm~125mm±1mm adjustable |
Timing Device | 9999X0.1s can be preset |
Thermocouple | U.S. original Omega Φ0.5mm armored stainless steel sheathed K-type thermocouple |
Temperature Measurement Distance | 25±1mm/55±1mm |
Temperature Measurement Range | MAX 1100°C |
Flame Test |
Adopt original imported flowmeter, the flow rate is adjustable, the accuracy is 1%, the following are the reference values of each test: 500W: 965±30ml/min, 54±2S(100-700°) Reference values of UL1581 power, flame height, temperature measurement time and flow: 225W: (16.5mm)/84±2S 405 ±10mL/min& 45±5 mm water 500W: 125mm(40mm)/54±2S A: 965 ±30mL/min&125±25 mm water B: 385 ±15mL/min&552±100 mm water C: 300 ±10mL/ min&600±125 mm water |
Copper Weight |
Ф9mm±0.01mm Copper head,Cu-ETP purity:99.96%, 10 ± 0 .05 g |
Gas Category | Methane |
Test Space | 4m³ |
Chamber and Appearance | Stainless steel chamber, black matt background with exhaust fan |
Size and weight | W*D*H=1.7*1.3*2.4m, about 350kg |