Brief: Looking for a straightforward way to test the pressure durability of electric water heater liners? This video provides a detailed walkthrough of the IEC 60335-2-21 Electric Water Heaters Pulse Pressure Withstand Testing Machine. You'll see how it performs continuous 24-hour testing, alternating pressures to simulate real-world conditions, and learn about its PLC-controlled operation and safety features for reliable compliance verification.
Related Product Features:
Complies with IEC 60335-2-21:2012 clause 22.47 for water heater liner pressure impact resistance testing.
Designed for 24-hour continuous operation with PLC control and a user-friendly touch screen interface.
Performs pressure cycling between 15% and 100±5% of rated pressure up to 80,000 times at 20-40 cycles per minute.
Includes automatic pressure holding for 10 minutes at maximum working pressure after every 10,000 cycles.
Features built-in safety mechanisms like leak detection, power-down protection, and emergency waterway shut-off.
Accommodates water heater liners up to 500L in capacity with customizable sample connectors.
Utilizes high-quality components including Mitsubishi PLC, Weinview touch screen, and stainless steel construction.
Provides precise pressure control with adjustable test frequency, cycle count, and pressure holding time settings.
FAQs:
What standard does this testing machine comply with?
This machine is designed to meet the requirements of IEC 60335-2-21:2012 clause 22.47 for testing the pulse pressure withstand capability of electric water heater liners.
How does the pressure cycling test work?
The test alternates pressurization between 15% and 100±5% of the rated pressure for up to 80,000 cycles at a frequency of 20-40 times per minute, with pressure holds after every 10,000 cycles to check for deformation.
What safety features are included in the machine?
The machine includes leak detection that automatically stops the test, power-down protection to save test data, emergency waterway shut-off valves, and electrical leakage protection for operator safety.
What is the maximum capacity of water heater liner that can be tested?
The machine can test water heater liners with a capacity of up to 500 liters, with water consumption adjusted according to the sample volume.