logo
Products
PRODUCTS DETAILS
Home > Products >
IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm

IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm

MOQ: 1
Price: Negotiable
Standard Packaging: Carton
Delivery Period: 10 Days
Payment Method: T/T
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2210-2E
Joint 1:
30±0.2 Mm
Joint 2:
60±0.2 Mm
Cylindrical:
R2±0.05 Mm
Spherical:
R4±0.05 Mm
Fingertip To Baffle:
120
Test Finger Diameter:
Ф12
Thrust Plate Diameter:
Ф56 Mm
Thrust Plate Length:
850 Mm
Product Description

 

IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm
 
Product information:
 
This test probe meets the requirements of IEC 60335-2-64 clause 20.2, etc. Test probe similar to that of probe B of IEC 61032 but having a non-circular stop face with a diameter of 56mm.


IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 0

 
 
Technical parameters:
 

ModelSN2210-2E
NameSimilar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm
Joint 130±0.2 mm
Joint 260±0.2 mm
Fingertip to baffle120
CylindricalR2±0.05 mm
SphericalR4±0.05 mm
Fingertip cutting bevel angle37o 0 -10′
Fingertip taper14 o 0 -10′
Test finger diameterФ12 0 -0.05
Thrust Plate diameterФ56 mm
Thrust Plate length850 mm
 

 
Operation Steps:
 
Please refer to the relevant standards; here, we take IEC 60335-2-64 clause 20.2 as an example:
For feed apertures and discharge apertures, unless otherwise specified, the test is carried out with test probe B of IEC 61032, but having a non-circular stop face with a diameter of 56 mm instead of 50 mm and with the distance between the tip of the test probe and the stop face being 120 mm. The 75 mm diameter guard is removed. The test probe is not inserted into the aperture for a linear distance of more than 850 mm, measured from the tip of the probe, if the aperture has a largest dimension of less than 150 mm.
NOTE 103 Moving parts that can be touched by the test probe through discharge apertures are not considered to be dangerous if they have a smooth surface or are constructed so that the risk of entrapment or injury is negligible.
For some appliances complete protection is impracticable and the test with the test probe is therefore not carried out. Examples of such appliances are

  • hand-held appliances;
  • slicers,
  • tin openers;
  • pastry rollers,
  • noodle strip cutters;
  • sieving machines;
  • peelers (discharge apertures only);
  • bone saws (circular or band type);
  • citrus juice squeezers;
  • egg beaters designated as attachable accessories,
  • knife sharpeners

.
Notice:
 
1. For verifying whether LIVE PARTS touched, the probe is equipped with alligator clip, recommended to work with our anti-shock probe experiment device or a 40~50V voltage indicator. Showing as following reference picture:

IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 1
2. Please do not damage the appliance shape (such as scratching, bending, etc.).
3. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.
4. Be careful of electric shock.

 

IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 2IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 3IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 4
 

Products
PRODUCTS DETAILS
IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm
MOQ: 1
Price: Negotiable
Standard Packaging: Carton
Delivery Period: 10 Days
Payment Method: T/T
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2210-2E
Joint 1:
30±0.2 Mm
Joint 2:
60±0.2 Mm
Cylindrical:
R2±0.05 Mm
Spherical:
R4±0.05 Mm
Fingertip To Baffle:
120
Test Finger Diameter:
Ф12
Thrust Plate Diameter:
Ф56 Mm
Thrust Plate Length:
850 Mm
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Carton
Delivery Time:
10 Days
Payment Terms:
T/T
Supply Ability:
10 Sets Per Month
Product Description

 

IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm
 
Product information:
 
This test probe meets the requirements of IEC 60335-2-64 clause 20.2, etc. Test probe similar to that of probe B of IEC 61032 but having a non-circular stop face with a diameter of 56mm.


IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 0

 
 
Technical parameters:
 

ModelSN2210-2E
NameSimilar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm
Joint 130±0.2 mm
Joint 260±0.2 mm
Fingertip to baffle120
CylindricalR2±0.05 mm
SphericalR4±0.05 mm
Fingertip cutting bevel angle37o 0 -10′
Fingertip taper14 o 0 -10′
Test finger diameterФ12 0 -0.05
Thrust Plate diameterФ56 mm
Thrust Plate length850 mm
 

 
Operation Steps:
 
Please refer to the relevant standards; here, we take IEC 60335-2-64 clause 20.2 as an example:
For feed apertures and discharge apertures, unless otherwise specified, the test is carried out with test probe B of IEC 61032, but having a non-circular stop face with a diameter of 56 mm instead of 50 mm and with the distance between the tip of the test probe and the stop face being 120 mm. The 75 mm diameter guard is removed. The test probe is not inserted into the aperture for a linear distance of more than 850 mm, measured from the tip of the probe, if the aperture has a largest dimension of less than 150 mm.
NOTE 103 Moving parts that can be touched by the test probe through discharge apertures are not considered to be dangerous if they have a smooth surface or are constructed so that the risk of entrapment or injury is negligible.
For some appliances complete protection is impracticable and the test with the test probe is therefore not carried out. Examples of such appliances are

  • hand-held appliances;
  • slicers,
  • tin openers;
  • pastry rollers,
  • noodle strip cutters;
  • sieving machines;
  • peelers (discharge apertures only);
  • bone saws (circular or band type);
  • citrus juice squeezers;
  • egg beaters designated as attachable accessories,
  • knife sharpeners

.
Notice:
 
1. For verifying whether LIVE PARTS touched, the probe is equipped with alligator clip, recommended to work with our anti-shock probe experiment device or a 40~50V voltage indicator. Showing as following reference picture:

IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 1
2. Please do not damage the appliance shape (such as scratching, bending, etc.).
3. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.
4. Be careful of electric shock.

 

IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 2IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 3IEC 60335-2-64 Similar Test Probe B But Having a Non-Circular Stop Face with Diameter 56mm 4
 

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2025 Sinuo Testing Equipment Co. , Limited . All Rights Reserved.