Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN775
Ambient Temperature:
10℃~35℃
Relative Humidity:
30%~90%
Burner Opening:
Φ7±0.05mm
Burning Time:
9999X0.1S
Burning Angle:
Tilt 45°±2°
Power Supply:
AC220V±10%, 50/60Hz
Inner Flame:
55±5mm
Outer Flame:
180±10mm
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
20 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
High Light:

Fibre Cable Vertical Flammability Test Device

,

Electric Cable Vertical Flammability Test Device

,

IEC60332-1-2 Flammability Test Chamber

Product Description

 

IEC60332-1-2 Single Insulated Wire Vertical Flammability Test Apparatus For Single Electric Cable Test

 
Overview:
 
The flammability chamber testing adopts integral type inlet ignition system, the combustion time delays 0.1s thus to ensure the sufficient time for gas burning. It also has matte black background, multi-functional flame measure gauge, full stainless steel chamber body, large observation window, imported high precision digital indicator, nice appearance. It is suitable for vertical burning test of a single electric wire, cable or optical fibre cable to determine the burning characteristics of its insulating material. 
   

IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 0
 

                                    
Principle:
 

The flame test apparatus meets the requirements of :
IEC 60332-1-1 “Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus”

IEC 60332-1-2 “Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame”

IEC 60332-1-3 “Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for determination of flamingdroplets/particles”
and etc.
 

Test principe: Integral air-intake automatic ignition system is adopted, and the combustion delay is only 0.1 seconds to ensure full combustion of gas.


Technical parameters:

 

Use Environment Power supply: single-phase AC220V±10%, 50/60Hz
Ambient temperature: 10℃~35℃ Relative humidity: 30%~90%
Control operation mode Electrical control, button operation (PLC control can be optional)
Blast burner standard IEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm,made of brass
Gas flow and gas category

Mixture gas: 650±30mL/min propane &10±0.5L/min air.
Dual flow meter adjustment

Flame application time 9999X0.1S
Flame application angle

Tilt 45°±2°, Adjustable
IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 1

Test flame calibration Temperature measuring copper head: 500W: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°C

Distance between the bunsen burner port to temperature measuring copper block:95 mm

IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 2

Flame height: Inner flame:55±5mm, outer flame:180±10mm
Temperature rise time from 100±5°C to 700°±3°C 45±5s
Combustion chamber WDH=300×450×1200±25mm
Test sample Length: 600±25mm, distance from the bottom:50mm
Fixed horizontal support of the sample 2, distance:550mm
Overall dimensions WDH=700×450×1350mm, weight about 120kg
 
How to position of test piece?
 
The test piece shall straightened and secured to two horizontal supports by means of a suitable size of copper wire, in a vertical position in the centre of the metal, so that the distance between the bottom of the upper support and the top of the lower support is (550±5)mm. In addition, the best piece shall be positioned so that the bottom of the specimen is approximately 50mm from the base of the enclosure. The vertical axis of the test piece shall be arranged centrally within the enclosure (i.e. 150mm from each side and 225mm from the rear).
 
IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 3
 
Sinuo techincal team well understand flammability testing requirements. Except supply various flammability test chamber , Sinuo can also have the ability to provide solutions for building the entire combustion laboratory. Sinuo team can well plan the the combustion laboratory's equipment layout , ventilation and exhaust, gas pipeline, safety measures, etc.
 
IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 4
 
products
PRODUCTS DETAILS
IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device
MOQ: 1
Price: Negotiable
Standard Packaging: Plywood
Delivery Period: 20 Days
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN775
Ambient Temperature:
10℃~35℃
Relative Humidity:
30%~90%
Burner Opening:
Φ7±0.05mm
Burning Time:
9999X0.1S
Burning Angle:
Tilt 45°±2°
Power Supply:
AC220V±10%, 50/60Hz
Inner Flame:
55±5mm
Outer Flame:
180±10mm
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
20 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
High Light

Fibre Cable Vertical Flammability Test Device

,

Electric Cable Vertical Flammability Test Device

,

IEC60332-1-2 Flammability Test Chamber

Product Description

 

IEC60332-1-2 Single Insulated Wire Vertical Flammability Test Apparatus For Single Electric Cable Test

 
Overview:
 
The flammability chamber testing adopts integral type inlet ignition system, the combustion time delays 0.1s thus to ensure the sufficient time for gas burning. It also has matte black background, multi-functional flame measure gauge, full stainless steel chamber body, large observation window, imported high precision digital indicator, nice appearance. It is suitable for vertical burning test of a single electric wire, cable or optical fibre cable to determine the burning characteristics of its insulating material. 
   

IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 0
 

                                    
Principle:
 

The flame test apparatus meets the requirements of :
IEC 60332-1-1 “Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus”

IEC 60332-1-2 “Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame”

IEC 60332-1-3 “Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for determination of flamingdroplets/particles”
and etc.
 

Test principe: Integral air-intake automatic ignition system is adopted, and the combustion delay is only 0.1 seconds to ensure full combustion of gas.


Technical parameters:

 

Use Environment Power supply: single-phase AC220V±10%, 50/60Hz
Ambient temperature: 10℃~35℃ Relative humidity: 30%~90%
Control operation mode Electrical control, button operation (PLC control can be optional)
Blast burner standard IEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm,made of brass
Gas flow and gas category

Mixture gas: 650±30mL/min propane &10±0.5L/min air.
Dual flow meter adjustment

Flame application time 9999X0.1S
Flame application angle

Tilt 45°±2°, Adjustable
IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 1

Test flame calibration Temperature measuring copper head: 500W: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°C

Distance between the bunsen burner port to temperature measuring copper block:95 mm

IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 2

Flame height: Inner flame:55±5mm, outer flame:180±10mm
Temperature rise time from 100±5°C to 700°±3°C 45±5s
Combustion chamber WDH=300×450×1200±25mm
Test sample Length: 600±25mm, distance from the bottom:50mm
Fixed horizontal support of the sample 2, distance:550mm
Overall dimensions WDH=700×450×1350mm, weight about 120kg
 
How to position of test piece?
 
The test piece shall straightened and secured to two horizontal supports by means of a suitable size of copper wire, in a vertical position in the centre of the metal, so that the distance between the bottom of the upper support and the top of the lower support is (550±5)mm. In addition, the best piece shall be positioned so that the bottom of the specimen is approximately 50mm from the base of the enclosure. The vertical axis of the test piece shall be arranged centrally within the enclosure (i.e. 150mm from each side and 225mm from the rear).
 
IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 3
 
Sinuo techincal team well understand flammability testing requirements. Except supply various flammability test chamber , Sinuo can also have the ability to provide solutions for building the entire combustion laboratory. Sinuo team can well plan the the combustion laboratory's equipment layout , ventilation and exhaust, gas pipeline, safety measures, etc.
 
IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device 4
 
Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.