Send Message
products
PRODUCTS DETAILS
Home > Products >
IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage

MOQ: 1
Price: Negotiable
Standard Packaging: Standard Exporting Boxed
Delivery Period: 10 Days
Payment Method: L/C, T/T
Supply Capacity: 60 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2210-81
Applied Standard:
IEC 62368-1
Applied Clause:
Clause 5.4.11
Test Sample:
Current Leakage
Test Condition:
Normal / Abnormal / Single Fault
Specification:
5000 Ω
Warranty:
One Year
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Standard Exporting Boxed
Delivery Time:
10 Days
Payment Terms:
L/C, T/T
Supply Ability:
60 Sets Per Month
High Light:

Clause 5.4.11 Non Inductive Resister

,

IEC 62368-1 Non Inductive Resister

,

Current Leakage Non Inductive Resister

Product Description

 

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage

 

Product Information:

 

This non-inductive resistor, category: wire-wound resistors. It is required by IEC 62368-1:2018 clause 5.4.11 and Annex H, IEC 60950-1 clause 2.4.2, IEC 60065-1:2014 clause 7. Used to test the leakage current between primary and secondary.

 

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage 0

Test Procedures and Operation

Please refer to the relevant standards.

Take IEC 60335-1 clause 8 as an example:

Voltages and currents are measured between the relevant parts and each pole of the supply source. Discharges are measured immediately after the interruption of the supply. The quantity of electricity in the discharge is measured using a resistor having a nominal non-inductive resistance.

NOTE 1 Details of a suitable circuit for measuring the current are given in figure 4 of IEC 60990.

NOTE 2 The quantity of electricity is calculated from the sum of all areas recorded on the voltage/time graph without taking voltage polarity into account.

 

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage 1

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage 2

products
PRODUCTS DETAILS
IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage
MOQ: 1
Price: Negotiable
Standard Packaging: Standard Exporting Boxed
Delivery Period: 10 Days
Payment Method: L/C, T/T
Supply Capacity: 60 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2210-81
Applied Standard:
IEC 62368-1
Applied Clause:
Clause 5.4.11
Test Sample:
Current Leakage
Test Condition:
Normal / Abnormal / Single Fault
Specification:
5000 Ω
Warranty:
One Year
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Standard Exporting Boxed
Delivery Time:
10 Days
Payment Terms:
L/C, T/T
Supply Ability:
60 Sets Per Month
High Light

Clause 5.4.11 Non Inductive Resister

,

IEC 62368-1 Non Inductive Resister

,

Current Leakage Non Inductive Resister

Product Description

 

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage

 

Product Information:

 

This non-inductive resistor, category: wire-wound resistors. It is required by IEC 62368-1:2018 clause 5.4.11 and Annex H, IEC 60950-1 clause 2.4.2, IEC 60065-1:2014 clause 7. Used to test the leakage current between primary and secondary.

 

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage 0

Test Procedures and Operation

Please refer to the relevant standards.

Take IEC 60335-1 clause 8 as an example:

Voltages and currents are measured between the relevant parts and each pole of the supply source. Discharges are measured immediately after the interruption of the supply. The quantity of electricity in the discharge is measured using a resistor having a nominal non-inductive resistance.

NOTE 1 Details of a suitable circuit for measuring the current are given in figure 4 of IEC 60990.

NOTE 2 The quantity of electricity is calculated from the sum of all areas recorded on the voltage/time graph without taking voltage polarity into account.

 

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage 1

IEC 62368-1 Clause 5.4.11 Non - Inductive Resister 5k Ω For Current Leakage 2

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.