Product Details:
Payment & Shipping Terms:
|
Applied Standard: | IEC 62368-1 | Applied Clause: | 4.1.4 |
---|---|---|---|
Nominal Content Volume: | 2880L (Customized) | Temperature Range: | -40 ℃~+85℃ (C Type) Air-cooled Type |
Heating Time: | RT~ 100℃ (2℃-3℃)/min | Cooling Time: | RT~ -40℃(0.7℃-1℃)/min |
Control Method: | 7-inch Color Touch Screen | Humidity Range: | (30 ~ 95)% RH |
High Light: | IEC 62368-1 Humidity Test Chamber,Clause 4.1.4 Humidity Test Chamber,Constant Temperature And Humidity Test Chamber |
IEC 62368-1 Clause 4.1.4 Programmable Constant Temperature And Humidity Test Chamber
Product information:
This programmable temperature chamber is required by IEC 62368-1:2018 clause 4.1.4, Y4.4, Y6.2, etc.
This test chamber is used for cold, heat, humidity and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc. The purpose is to confirm the products reliability of storage and transportation under high and low temperature alternating heat and humidity.
It conforms to standards:
IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”
IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”
IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”
IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”
Features:
1. The test system has advanced and reasonable structural design, standardized manufacturing process, beautiful appearance and generous appearance.
2. The main functional components of the test chamber are world famous branded ones. The test chamber has best control of noise and energy saving.
3. The matching of components and assembly is good. The main functional components are imported from the internationally branded companies, which improves the safety and reliability of the test chamber, and can ensure the long-term, high-frequency usage purposes.
4. The equipment has good operability, maintainability, good temperature stability and durability, good safety performance. It does not pollute the environment and endanger human health.
Technical parameters:
Applied standard | IEC 62368-1 |
Applied clause | 4.1.4 |
Sample limitation | This test chamber prohibits: Testing or storage of flammable, explosive, and volatile substance samples Testing or storage of samples of corrosive substances Testing or storage of biological samples Testing or storage of strong electromagnetic emission source samples Testing or storage of radioactive material samples Test or storage of highly toxic substance samples Testing or storage of samples that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive materials during testing or storage |
Volume, size and weight | |
Nominal content volume | (2880L) |
Inner chamber size | W 2400×D 800×H 1500 (mm) |
External dimensions | Approx. W3100×D1320×H2100 (mm) |
Weight | Approx. (1500) KG |
Performance | |
Temperature range | -40 ℃~+85℃ (C type) Air-cooled type |
Humidity range |
(30 ~ 95)% RH (Refer to temperature and humidity controllable range chart, no active wet and heat load) Temperature and humidity controllable range chart |
Temperature fluctuation | ≤0.5℃ (The temperature fluctuation is half of the difference between the measured maximum temperature and the minimum temperature at the center point) |
Temperature uniformity | ≤2.0℃ (Temperature uniformity is the arithmetic mean of the difference between the highest and lowest temperature measured in each test) |
Humidity deviation | ≤ 2%R.h (>75%), 3%R.h. (<75%) |
Heating time | RT~ 100℃ (2℃-3℃)/min |
Cooling time | RT~ -40℃(0.7℃-1℃)/min |
Working noise
|
80dB(A) (1m in front of the gate, 1.2m above the ground, in free space) |
Control System | |
Controller | 7-inch color touch screen temperature controller, English display |
Operation mode | Fixed value/program mode: users can perform programming test and constant test according to test requirements and needs |
Setting method | Set on the touch screen |
Input | Thermal resistance signal |
Output | Multi-point temperature and humidity signal output |
Control method | Control and adjust the temperature and humidity in the test chamber, and automatically determine the working status of each executive elements (such as compressor, fan, heater, water circuit, etc.) PID action and automatic calculation function Ratio band (PB): 0.1%~999.9% Integration time (IT): SR-92/SR-93 1~3600 seconds Differential time (DT): SR-92/SR-93 1~1200 seconds |
Setting range | Temperature: -100~+300℃, humidity: 0~100%RH |
Control precision | Temperature: 0.1°C, humidity: 0.1%RH, time 0.1 minutes |