Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SNBT4008NFA-5V6AS
Voltage Range:
75mV-15V25mV-5V
Min. Discharge Voltage:
0V
Cutoff Current:
0.2mA;12mA
Current Range:
0.5mA~0.1A; 0.1A~6A
Accuracy:
± 0.05% Of FS
Channels Per Unit:
8
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood
Delivery Time:
1 Month
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
Highlight:

high frequency vibration generator

,

battery discharge analyzer

Product Description

5V 6A Lithium Ion Batteies and Cells Charge Discharge Life Cycle Dual Range Capacity Test Equipment
 
 

Overview:
 
This Li-ion battery charge discharge testing equipment meets the requirements of lithium oon battery and cell pulse charge and discharge test, DC internal resistance (DCIR) test, cycle life (Cycle Life) test, rate charge and discharge test. It has two current range: range 1: 0.5mA~0.1A; Range 2: 0.1A~6A, which can test the small capacity li-ion batteries and the test result are more accuracy.

This testing equipment comes with unique software, which can run on computer to achieve romote control and minitor.
This series of battery testing systems are widely used in various research institutions, universities and power battery manufacturers.
 
Standards & Clauses:
 
Conforms to IEC62133-1/-2:2017 clause 7.1, 7.2.1, 7.3.8, 7.3.9, IEC62133-1/-2:2012 clause8.1.1, 8.1.2, 8.2.1, 8.3.6, 8.3.7 IEC60086-4 clause 6.5.8 6.5.9 IEC60622, IEC60623, IEC 60086-1, IEC61951, IEC61960
 
Technical Parameters:

 

Project index

Parameter index

Input Power AC220V ±10% / 50Hz
resolution AD: 16bit; DA: 16bit
Input Resistance ≥1MΩ
Input Power 425W
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode Independent Control
Voltage Constant voltage control range 25mV-5V
Min Voltage Discharge 0V(with cylinder spring clamp)
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS
Current Output of per channel Range1: 0.5mA~0.1A; Range2: 0.1A~6A
Accuracy ± 0.05% of FS
Cut-off current of CV Range1: 0.2mA; Range2: 12mA
Stability ± 0.05% of FS
Power Per Channel Output Power 30W
Stability ± 0.1% of FS
Time Rise Time The Current 10%-90% Hardware Response Time is 1ms
Step Time Range

Single Step Time Range≤365*24 h,

Time Form Support 00:00:00.000(h, min, s, ms)

Data Recording Record Condition Time△t:100ms
Voltage△U: 10mV
Current△I:Range1:0.2mA; Range2:12mA
Record Frequency 10Hz
Charge Charge Mode

Constant Current Charge, Constant Voltage Charge, 

Constant Current and Constant Voltage,  ChargeConstant Power Charge

End Conditon Voltage, Current, Relative Time, Capacity, -△V
Discharge Discharge Mode Constant Current Discharge, Constant Power Discharge, Constant Resistance discharge
End Condition Voltage, Current, Relative Time, Capacity
Pulse Charge CCC, CPC
Discharge CCD, CPD
Minimum Pulse Width 500ms
Pulse 32 pulse setting in one step
Automated Switch Automated switch from charge to discharge for each pulse
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function, Max Support 3 Layers
Protection Software Protection
  • Power-down Data Protection
  • Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time
Voltage and Current Testing Sample 4-wire connecting
Noise <85dB
Data Management MYSQL Database
Communication Means TCP/IP Protocol
Data Output EXCEL,TXT
Communication Interface Ethernet Port
Per Unit Main Channels No. 8
Dimensions 3U, W*D*H: 480*330*130(mm)
 

Equipment Working Environment:
 

Project index

Parameter index

Working Temperature Range 0℃~40℃
Storage Temperature Range 0℃~45℃
Working Environment Relative Humidity Range 30% ~ 80% RH
Storage Environment Relative Humidity Range 30% ~ 90% RH
 

 

The number of channels, voltage range, current range and etc. can be customized according client's specific requirements and specimen. Please email or call to Sinuo for further assistance.


5V 6A Li-ion Batteies and Cells Life Analyzer High Precision Dual Range Capacity Test Equipment 0

 

products
PRODUCTS DETAILS
5V 6A Li-ion Batteies and Cells Life Analyzer High Precision Dual Range Capacity Test Equipment
MOQ: 1
Price: Customized
Standard Packaging: Plywood
Delivery Period: 1 Month
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SNBT4008NFA-5V6AS
Voltage Range:
75mV-15V25mV-5V
Min. Discharge Voltage:
0V
Cutoff Current:
0.2mA;12mA
Current Range:
0.5mA~0.1A; 0.1A~6A
Accuracy:
± 0.05% Of FS
Channels Per Unit:
8
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood
Delivery Time:
1 Month
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
Highlight

high frequency vibration generator

,

battery discharge analyzer

Product Description

5V 6A Lithium Ion Batteies and Cells Charge Discharge Life Cycle Dual Range Capacity Test Equipment
 
 

Overview:
 
This Li-ion battery charge discharge testing equipment meets the requirements of lithium oon battery and cell pulse charge and discharge test, DC internal resistance (DCIR) test, cycle life (Cycle Life) test, rate charge and discharge test. It has two current range: range 1: 0.5mA~0.1A; Range 2: 0.1A~6A, which can test the small capacity li-ion batteries and the test result are more accuracy.

This testing equipment comes with unique software, which can run on computer to achieve romote control and minitor.
This series of battery testing systems are widely used in various research institutions, universities and power battery manufacturers.
 
Standards & Clauses:
 
Conforms to IEC62133-1/-2:2017 clause 7.1, 7.2.1, 7.3.8, 7.3.9, IEC62133-1/-2:2012 clause8.1.1, 8.1.2, 8.2.1, 8.3.6, 8.3.7 IEC60086-4 clause 6.5.8 6.5.9 IEC60622, IEC60623, IEC 60086-1, IEC61951, IEC61960
 
Technical Parameters:

 

Project index

Parameter index

Input Power AC220V ±10% / 50Hz
resolution AD: 16bit; DA: 16bit
Input Resistance ≥1MΩ
Input Power 425W
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode Independent Control
Voltage Constant voltage control range 25mV-5V
Min Voltage Discharge 0V(with cylinder spring clamp)
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS
Current Output of per channel Range1: 0.5mA~0.1A; Range2: 0.1A~6A
Accuracy ± 0.05% of FS
Cut-off current of CV Range1: 0.2mA; Range2: 12mA
Stability ± 0.05% of FS
Power Per Channel Output Power 30W
Stability ± 0.1% of FS
Time Rise Time The Current 10%-90% Hardware Response Time is 1ms
Step Time Range

Single Step Time Range≤365*24 h,

Time Form Support 00:00:00.000(h, min, s, ms)

Data Recording Record Condition Time△t:100ms
Voltage△U: 10mV
Current△I:Range1:0.2mA; Range2:12mA
Record Frequency 10Hz
Charge Charge Mode

Constant Current Charge, Constant Voltage Charge, 

Constant Current and Constant Voltage,  ChargeConstant Power Charge

End Conditon Voltage, Current, Relative Time, Capacity, -△V
Discharge Discharge Mode Constant Current Discharge, Constant Power Discharge, Constant Resistance discharge
End Condition Voltage, Current, Relative Time, Capacity
Pulse Charge CCC, CPC
Discharge CCD, CPD
Minimum Pulse Width 500ms
Pulse 32 pulse setting in one step
Automated Switch Automated switch from charge to discharge for each pulse
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function, Max Support 3 Layers
Protection Software Protection
  • Power-down Data Protection
  • Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time
Voltage and Current Testing Sample 4-wire connecting
Noise <85dB
Data Management MYSQL Database
Communication Means TCP/IP Protocol
Data Output EXCEL,TXT
Communication Interface Ethernet Port
Per Unit Main Channels No. 8
Dimensions 3U, W*D*H: 480*330*130(mm)
 

Equipment Working Environment:
 

Project index

Parameter index

Working Temperature Range 0℃~40℃
Storage Temperature Range 0℃~45℃
Working Environment Relative Humidity Range 30% ~ 80% RH
Storage Environment Relative Humidity Range 30% ~ 90% RH
 

 

The number of channels, voltage range, current range and etc. can be customized according client's specific requirements and specimen. Please email or call to Sinuo for further assistance.