Send Message
Home ProductsBattery Testing Equipment

Motorcycle Lead Acid Battery Testing Equipment Cell Charge Discharge Capacity Test 20V 50A

Certification
China Sinuo Testing Equipment Co. , Limited certification
China Sinuo Testing Equipment Co. , Limited certification
Customer Reviews
Perfect on-site installation service, excellent training and technology support. Absolutely helps us a lot.

—— Aryan Das

Thanks. Your company is very professional, I am sure we will have good cooperation in the future.

—— Fernando Fuentealba

It's a great purchase, good products received with good packing, will back to you for next needs.

—— Sarah Rashad

I'm Online Chat Now

Motorcycle Lead Acid Battery Testing Equipment Cell Charge Discharge Capacity Test 20V 50A

Motorcycle Lead Acid Battery Testing Equipment Cell Charge Discharge Capacity Test 20V 50A
Motorcycle Lead Acid Battery Testing Equipment Cell Charge Discharge Capacity Test 20V 50A Motorcycle Lead Acid Battery Testing Equipment Cell Charge Discharge Capacity Test 20V 50A

Large Image :  Motorcycle Lead Acid Battery Testing Equipment Cell Charge Discharge Capacity Test 20V 50A

Product Details:
Place of Origin: China
Brand Name: Sinuo
Certification: Calibration Certificate (Cost Additional)
Model Number: SNBT4004FA-50A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Customized
Packaging Details: Plywood
Delivery Time: 1 Month
Payment Terms: T/T, L/C, Western Union, MoneyGram
Supply Ability: 10 Sets Per Month
Detailed Product Description
Voltage Range: 100mV~20V Min. Discharge Voltage: 2.5V
Current Range: 250m A~50A Accuracy: ± 0.1% Of FS
Power Per Channel: 1000W Channels Per Unit: 4
High Light:

battery charge discharge test equipment

,

high frequency vibration generator

20V 50A Motorcycle Lead Acid Battery And Cell Charge Discharge Capacity Test Equipment
 
Overview:
This battery charge discharge testing equipment meets the requirements of battery and cell pulse charge and discharge test, DC internal resistance (DCIR) test, cycle life (Cycle Life) test, rate charge and discharge test. This testing equipment comes with unique software, which can run on computer to achieve romote control and minitor.
This series of battery testing systems are widely used in various research institutions, universities and power battery manufacturers.
Standards & Clauses:
Conforms to IEC62133-1/-2:2017 clause 7.1, 7.2.1, 7.3.8, 7.3.9, IEC62133-1/-2:2012 clause8.1.1, 8.1.2, 8.2.1, 8.3.6, 8.3.7 IEC60086-4 clause 6.5.8 6.5.9 IEC60622, IEC60623, IEC 60086-1, IEC61951, IEC61960
Technical Parameters:
 
 

Project index

Parameter index

Input PowerAC 380V±10%/50Hz (can be customized)
ResolutionAD:16bit; DA:16bit
Input Resistance≥1MΩ
Input Power5570W
Channel Control FeatureConstant current source and constant voltage source adopt independent double closed loop structure
Channel Control ModeIndependent control
VoltageVoltage Range Per Channel100mV-20V
Minimum discharge voltage2.5V
Accuracy± 0.1% of FS
Stability± 0.1% of FS
CurrentCurrent Range Per Channel250m A~50A
Accuracy± 0.1% of FS
Stability± 0.1% of FS
PowerOutput Power Per Channel1000W
Stability± 0.2% of FS
TimeCurrent Response TimeTime of current rising to 20A is 20ms
Step Time Range1s~365*24 hour, Time Form Support 00:00:00:000(h, min, s, ms)
Data RecordingRecord ConditionTime△t: 100ms
Voltage△U:40mV
Current△I: 100mA
Record Frequency10Hz
ChargeCharge ModeConstant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant current and constant voltage of the battery pack
Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
DischargeDischarge ModeConstant current discharge, constant power discharge, constant resistance discharge
Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
Pulse ModeCharge modeConstant current mode, Constant power mode
Discharge modeConstant current mode, Constant power mode
Min. pulse width500ms
Number of pulseSingle pulse step supports 32 different pulses
Continuous switching of charge and dischargeA pulsed step can achieve continuous switching from charge to discharge
Cutoff conditionVoltage, relative time
DCIR TestSupports custom point retrieval for DCR calculations
CycleLoop Measure Range1~65535 times
Max Steps Per Loop254
Nested LoopWith nested loop function, max support 3 layers
ProtectionSoftware Protection
  • Power-down Data Protection
  • Off-line Testing Function
  • Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time, Single cell difference
  • With anti-reverse connection function, IP Protection Grade: IP20
Voltage and current detection samplingFour-wire connection
Noise<85dB
DatabaseMySQL Database
A Means of Communication of Upper MachineTCP/IP Protocol
Data OutputEXCEL, TXT, Diagram
Communication InterfaceEthernet Port
Main Channels No. Per Unit4
Dimensions18U chamber, W*D*H:600*600*1000(mm)
Fixture TypeTo be determined
 


Equipment Working Environment:
 

Project index

Parameter index

Working Temperature Range10℃ ~ 40℃
Storage Temperature Range-10℃ ~ 50℃
Working Environment Relative Humidity Range≤70% RH (No condensation)
Storage Environment Relative Humidity Range≤80% RH (No condensation)
Auxiliary channel voltage range (optional and customized)-5V~5V
Auxiliary channel voltage accuracy
(optional and customized)
±0.1%ofFS


The number of channels, voltage range, current range and etc. can be customized according client's specific requirements and specimen. Please email or call to Sinuo for further assistance.
 
Motorcycle Lead Acid Battery Testing Equipment Cell Charge Discharge Capacity Test 20V 50A 0

Contact Details
Sinuo Testing Equipment Co. , Limited

Contact Person: Ms. Zoe Zou

Tel: +86 13527656435

Fax: 86-020-39185976

Send your inquiry directly to us (0 / 3000)