switch endurance tester
"
IEC 60884-1 Clause 24.3 Rigid Steel Sheet Test Cylinder For Socket - Outlet Torque Test
IEC 60884-1 Clause 24.3 Rigid Steel Sheet Test Cylinder for Socket-outlet Torque Test Product information: The test cylinder meets the requirements of IEC 60884-1 2013 clause 24.3, IEC 60669-1 clause 20.2. It is used to check the reliability of the fixed structure of surface type sockets. Equipment characteristics: This device is processed by treated steel tube, use to check the mechanical strength of the surface type sockets. Technical parameters: Radius of cylinder >200mm,
Plug Pins Insulating Sleeves Abrasion Test Apparatus IEC 60884-1 Figure 28 4N
IEC 60884-1 Figure 28 Insulating Sleeves of Plug Pins Abrasion Test Apparatus Product information: The plug pins insulating sleeves abrasion test apparatus meets the requirements of IEC 60884-1 2013 clause 24.7 and figure 28, BS1363-1 figure 9. It is used to test the abrasion resistance strength of insulation sleeve of plug pins. Technical parameters: Power Supply AC220V, 50Hz or match the client's site local power supply Test Stations Single station (can be customized) Test
Body Plug Pin Fixation Verifying Test Apparatus Figure 30 IEC60884 Clause 24.10
IEC 60884-1 Fig. 30 Apparatus to Verify the Fixation of Pins in the Body of the Plug Product information: The plug pin fixation verifying test apparatus meets the requirements of IEC 60884-1 2013 clause 24.10 and figure 30. Technical parameters: Station 1 station Weights 4N, 20N, 30N for ordinary hole, one in each; 50N, 20N with hook, one in each Gauges provide 6A plug gauge, 10A plug gauge, 16 plug gauge, one each (according to different plug standard requirements) Hole size
IEC 61058-1 Household Appliances Couplers Endurance Test System
IEC 61058-1 Household Appliances Couplers Endurance Test System Standards & Clauses: IEC61058-1:2008 Switches for appliances Part1: General requirements clause 17 IEC60884-1:2006 Plugs and socket-outlets for household and similar purposes- Part1: General requirements clause 20 and 21 IEC60669-1:2007 Switches for household and similar fixed-electrical installations - Part1: General requirements clause 18 and 19 IEC60320-1:2007 Appliance couplers for household and
IEC 60669-1 Three Stations 300V 30A Load Cabinet For Switch Life Tester
IEC 60669-1 Three Stations 300V 30A Load Cabinet for Switch Life Tester Equipment Introduction: The load cabinet is designed and manufactured according to IEC60884-1, IEC61058-1, IEC60669-1 and etc. It is applicable for household and similar fixed electrical installations switches and plug sockets breaking capacity and normal operation test, the rated voltage of the switch is not greater than 280V and the rated current less than 16A. The purpose is assessing whether the
IEC 60669-1 Self Locking Switch Normal Operation Life Tester
IEC 60669-1 High Quality Self-Locking Switch Normal Operation Life Tester Equipment overview: The test equipment has a signaling station to test linear switches (including self-locking switches, plugs and sockets) by changing to different sample fixtures. The equipment complies with the standard clauses of IEC 60669-1 Clauses 18 and 19, IEC 60884-1: 2013 Clauses 20 and 21, Figure 16, IEC 61058-1, IEC 60065:2014 Clauses 14.7 and 15.1. Used in conjunction with a load cabinet
Clause 18 Microwave Oven Door Endurance Test Equipment IEC 60335-2-25
IEC 60335-2-25 Clause 18 Microwave Oven Door Endurance Test Equipment Brief Introduction: It is conforms the standard of IEC60335-2-25:2006 clause 18.This apparatus is a special tester which is used to test the abrasion resistance of the microwave oven door system, including the structure of the hinge, microwave seal and other related parts during use. The mechanical arm is driven by the motor which drives the vacuum suction cup to suck the microwave oven door to open and
IEC60898-1 circuit breakers 28-day Tripping Characteristics Tester
IEC60898-1 Circuit Breakers 28-day Tripping Characteristics Tester Standards & Clauses: The design and manufacturing of this test equipment follow the provisions outlined in IEC 60898-1 (9.1, 9.8, 9.9, 9.10), IEC 60947-1 (7.2.1), along with other related standards. Product Information: The equipment is designed to verify the compliance of circuit breakers with standard requirements by applying 1.13, 1.45, and 2.55 times the rated current to check whether tripping occurs
IEC 60335-2-36 Clause 18.102 Commercial Induction Cooker Heat Resistance Test Device
IEC 60335-2-36 Clause 18.102 Commercial Induction Cooker Heat Resistance Test Device Product information: The test equipment conforms to the standard requirements of IEC60335-2-36 clause 18.102.The equipment is used to verify appliances equipped with glass ceramics or similar surface materials. The structure should be able to ensure the thermal stress occurring in normal use. And after 500 cycles of use, the surface water overflow resistance of the product, the heat