flame test chamber
"
BS EN 12983-1 Annex A Cookware Handle Burning Resistance Test Apparatus With PLC Control
BS EN 12983-1 Annex A Cookware Handle Burning Resistance Test Apparatus With PLC Control Product Information: The design of the Cookware Handle Burning Resistance Test Apparatus complies with annex F of standard TZS 683:2022, Annex A of standard EN 12983-1: 2023, and ES 573:2021 It uses a standard alcohol lamp, a non-stick pan steel base installation platform, an alcohol lamp moving block, and a wind-proof cabinet. In the wind-proof cabinet, the non-stick pan is first
IEC 60086-4 Battery Test Equipment Mechanical Abuse Of Cylindrical Cells Impact Test
IEC 60086-4 Battery Test Equipment Mechanical Abuse Of Cylindrical Cells Impact Test Overview: Battery impact test equipment is used to test the safety performance of batteries from different heights through different masses and different impact areas. Batteries are qualified if there is no flame or explosion after the impact test. Standards Compliant: Comply with IEC 60086-4: 2014 Article 6.5.2 Figure 3, UL1642:2012 Article 14 Figure 14.1, UL 2054, UN38.3, GB/T 18287-2013,
4 Stations Washing Machine Consumption Test System
4 Stations Washing Machine Consumption Test System System Overview Laboratory Introduction This laboratory utilizes insulated chamber panels and an accompanying air reprocessing unit to provide a stable temperature and humidity environment for washing machine performance testing. Utilizing a constant temperature water system and related measurement and control systems, the units under test can operate continuously at a temperature of 232C and a humidity control of 65%5%.
IEC 60086-4 Battery Testing Equipment Cylindrical Battery Cells Mechanical Abuse 9.1kg Impact Test
IEC 60086-4 Cylindrical Battery Cells Mechanical Abuse 9.1kg Impact Test Equipment Overview: The battery impact test equipment is used to test battery safety performance through different masses and different impact areas from different height. The battery is verified as qualified on the condition of no flames or explosion after the impact test. Standards Compliant: It is confirm to IEC 60086-4: 2014 clause 6.5.2 figure 3, UL1642:2012 clause 14 figure 14.1, UL 2054, UN38.3,
IEC 60598-1 PLC Controller Thermal Enclosure For Luminaries Endurance Test
IEC 60598-1 PLC Controller Thermal Enclosure For Luminaries Endurance Test Overview: The luminaire durability aging test room meets the requirements of Section 12.3 of the Chapter 12 Endurance Test and Annex K Temperature Measurement of IEC60598-1:2014. This testing system has excellent cost performance, long-term operating temperature stability, high precision test data, good test results, highly recommended by lighting manufacturers, quality and technology supervision
UL 1642 FIG. 20.1 Single Station Lithium Battery Fire Exposure Tester
UL 1642 FIG. 20.1 Single Station Lithium Battery Fire Exposure Tester Overview: This instrument complies with UL2054 Article 22 (Figure 22.1), UL 1642-2009 Article 20 (Figure 20.1), GB 31241-2014 Article 7.9 (Figure E.2). Battery fire exposure tester is a necessary test equipment for battery manufacturers and quality inspection departments. The equipment is characterized by easy operation, safety and reliability, and high precision. It is the ideal test equipment for battery