Send Message
products
PRODUCTS DETAILS
Home > Products >
Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell

MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2808
Input Power:
AC220V 50HZ
Control Method:
PLC Control
Drive Mode:
Cylinder
Test Station:
1 Station
Test Pressure:
0.01-0.5Mpa
Hold Time:
0-999999s
Water Injection:
Automatic Switch Valve
Sealing Rubber Pad:
Standard 10 Pieces
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
10 sets per month
High Light:

Medical SSPPM Shell Leak Test Fixture

,

SSPPM Bezel Leak Test Fixture

,

Waterproof Ability Leak Test Fixture

Product Description

 

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell

 

Product Information:

 

The test device is designed and manufactured strictly according to the customer's customized requirements. It is used for the verification of the waterproof ability of the medical SSPPM shell. It is a special test equipment and is suitable for testing and certification agencies and factory laboratory testing departments.

Equipment principle: Use the cylinder to drive the down-pressing fixture, and tightly compress the frame around the sample, so that the down-pressing fixture and the upper surface of the sample form a water storage tank. At the same time, due to the effect of two layers of sealing rubber pads, the lower surface of the sample and the lower groove of the compartment form a sealed air-filled compartment, which are divided into two inflatable compartments, one is the LCD sealed compartment area (LCD compartment), and the other is the keypad sealed compartment area (keypad compartment).

The system controls to fill the water storage tank with water, and then automatically inflate the LCD compartment to the set pressure (monitored by the pressure sensor), and set the time at constant pressure, and observe whether there are bubbles around the LCD upper surface of the sample in the water storage tank. Then deflate the LCD compartment, re-inflate the keypad compartment, observe whether there are bubbles in the sample keypad compartment area in the water storage tank, and accurately judge the leak point.

 

Technical Parameters:

 

No. Item Content
1 Input power AC220V 50HZ, 2kW
2 Control PLC control, touch screen operation
3 Test station 1 station, can be customized
4 Drive Cylinder
5 Test pressure 0.01-0.5Mpa, external air source, pressure sensor monitoring and display
6 Pressure hold time 0-999999s, can be set
7 Sample down-pressing fixture Customized according to the sample, standard 1 set
8 Fixture compartment Customized according to the sample, standard 1 set
9 Sealing rubber pad Customized according to the sample, standard 10 pieces (can seal the LCD compartment and keypad compartment)
10 Water injection Automatic switch valve

Maintenance:

1 Routine maintenance: disconnect the power supply when the device is not working, and keep the device clean.

2 Regular maintenance: Regularly lubricate the bearing (lubricant can use PARKER EO-NIROMONT, etc., and perform maintenance every 3-6 months)

3 Calibrate the pressure sensor once a year.

4 Regularly drain the water in the air filter, and regularly add lubricating oil to the lubricant spray bottle (you can add it when the amount of lubricate oil is too low)

 

Troubleshooting:

 

Symptoms Reason Troubleshooting
The power light is off

1. Blown fuse, bad power connection.

2. The indicator light is damaged.

1. Check the power socket, measure the supply voltage, replace the indicator light.

2. Replace the fuse core.

Touch screen failure

1. The DC power supply has no 24V voltage.

2. The program is corrupted.

3. The communication cable between HMI and PLC is not connected or damaged.

1. Check DC power.

2. Re-download the touch screen program.

3. Replace the communication line.

 

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell 0

 

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell 1

 

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell 2

products
PRODUCTS DETAILS
Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell
MOQ: 1
Price: Customized
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 sets per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN2808
Input Power:
AC220V 50HZ
Control Method:
PLC Control
Drive Mode:
Cylinder
Test Station:
1 Station
Test Pressure:
0.01-0.5Mpa
Hold Time:
0-999999s
Water Injection:
Automatic Switch Valve
Sealing Rubber Pad:
Standard 10 Pieces
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
10 sets per month
High Light

Medical SSPPM Shell Leak Test Fixture

,

SSPPM Bezel Leak Test Fixture

,

Waterproof Ability Leak Test Fixture

Product Description

 

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell

 

Product Information:

 

The test device is designed and manufactured strictly according to the customer's customized requirements. It is used for the verification of the waterproof ability of the medical SSPPM shell. It is a special test equipment and is suitable for testing and certification agencies and factory laboratory testing departments.

Equipment principle: Use the cylinder to drive the down-pressing fixture, and tightly compress the frame around the sample, so that the down-pressing fixture and the upper surface of the sample form a water storage tank. At the same time, due to the effect of two layers of sealing rubber pads, the lower surface of the sample and the lower groove of the compartment form a sealed air-filled compartment, which are divided into two inflatable compartments, one is the LCD sealed compartment area (LCD compartment), and the other is the keypad sealed compartment area (keypad compartment).

The system controls to fill the water storage tank with water, and then automatically inflate the LCD compartment to the set pressure (monitored by the pressure sensor), and set the time at constant pressure, and observe whether there are bubbles around the LCD upper surface of the sample in the water storage tank. Then deflate the LCD compartment, re-inflate the keypad compartment, observe whether there are bubbles in the sample keypad compartment area in the water storage tank, and accurately judge the leak point.

 

Technical Parameters:

 

No. Item Content
1 Input power AC220V 50HZ, 2kW
2 Control PLC control, touch screen operation
3 Test station 1 station, can be customized
4 Drive Cylinder
5 Test pressure 0.01-0.5Mpa, external air source, pressure sensor monitoring and display
6 Pressure hold time 0-999999s, can be set
7 Sample down-pressing fixture Customized according to the sample, standard 1 set
8 Fixture compartment Customized according to the sample, standard 1 set
9 Sealing rubber pad Customized according to the sample, standard 10 pieces (can seal the LCD compartment and keypad compartment)
10 Water injection Automatic switch valve

Maintenance:

1 Routine maintenance: disconnect the power supply when the device is not working, and keep the device clean.

2 Regular maintenance: Regularly lubricate the bearing (lubricant can use PARKER EO-NIROMONT, etc., and perform maintenance every 3-6 months)

3 Calibrate the pressure sensor once a year.

4 Regularly drain the water in the air filter, and regularly add lubricating oil to the lubricant spray bottle (you can add it when the amount of lubricate oil is too low)

 

Troubleshooting:

 

Symptoms Reason Troubleshooting
The power light is off

1. Blown fuse, bad power connection.

2. The indicator light is damaged.

1. Check the power socket, measure the supply voltage, replace the indicator light.

2. Replace the fuse core.

Touch screen failure

1. The DC power supply has no 24V voltage.

2. The program is corrupted.

3. The communication cable between HMI and PLC is not connected or damaged.

1. Check DC power.

2. Re-download the touch screen program.

3. Replace the communication line.

 

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell 0

 

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell 1

 

Leak Test Fixture For SSPPM Bezel For Test Waterproof Ability Of The Medical SSPPM Shell 2

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.