Send Message
products
PRODUCTS DETAILS
Home > Products >
Protective Mask Dead Space Tester Automatic Inhaled Gas CO2 Volume Fraction Detector

Protective Mask Dead Space Tester Automatic Inhaled Gas CO2 Volume Fraction Detector

MOQ: 1
Price: Negotiable
Standard Packaging: Plywood
Delivery Period: 30 Days
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 20 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN122609
Simulated Breathing Frequency:
10~40 Times /min
Tidal Volume Range:
0.5~3.0L/min
Carbon Dioxide Flowmeter Range:
≥ 40L/min
Carbon Dioxide Analyzer Range:
≥ 12%
Breathing Frequency:
20 Times/ Min
Breathing Tidal Volume:
1.5L
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
30 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
20 Sets Per Month
High Light:

mask testing machine

,

mask testing equipment

Product Description

 

Protective Mask Dead Space Tester Automatic Inhaled Gas CO2 Volume Fraction Detector

 

Product overview:

 

The protective mask dead space tester is used for the detection of the protective mask dead space, that is, the volume fraction of CO2 in the inhaled gas.

 

Equipment advantages:

 

1. The test process is completely controlled by a computer program, which realizes automatic detection, automatic recording, and automatic calculation of the change of the carbon dioxide concentration value of the inhaled gas during the entire test process. The operation is simple and easy to use.

2. There is no need to adjust the breathing frequency and the amount of breathing during the test. The breathing frequency and the amount of breathing can be changed by simple parameter setting operations on the computer. The adjustment is very convenient and accurate.

3. The one-way valve that controls the breathing channel is automatically controlled by the ventilator using a solenoid valve group, which is completely synchronized with the action of the ventilator, making the detection result more accurate.

4. All data of the test process is automatically saved in the computer, and a test report is automatically generated. The data of the entire process can be viewed through the computer at any time, and a report of the test results can be printed at any time.

 

Technical parameters:

 
Name Specifications
Simulated breathing frequency 10~40 times /min
Adjustable range of simulated tidal volume 0.5~3.0L/min
Volume fraction of the carbon dioxide gas source 5.0±0.1%
Range of carbon dioxide flowmeter ≥ 40L/min
Range of carbon dioxide analyzer ≥ 12%, accuracy ≥ 0.1%
Electric fan Wind speed 0.5m/s
Breathing frequency 20 times/ min
Breathing tidal volume 1.5L
Power AC220V 50Hz
Dimensions 980mm*820mm*1400mm
products
PRODUCTS DETAILS
Protective Mask Dead Space Tester Automatic Inhaled Gas CO2 Volume Fraction Detector
MOQ: 1
Price: Negotiable
Standard Packaging: Plywood
Delivery Period: 30 Days
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 20 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN122609
Simulated Breathing Frequency:
10~40 Times /min
Tidal Volume Range:
0.5~3.0L/min
Carbon Dioxide Flowmeter Range:
≥ 40L/min
Carbon Dioxide Analyzer Range:
≥ 12%
Breathing Frequency:
20 Times/ Min
Breathing Tidal Volume:
1.5L
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
30 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
20 Sets Per Month
High Light

mask testing machine

,

mask testing equipment

Product Description

 

Protective Mask Dead Space Tester Automatic Inhaled Gas CO2 Volume Fraction Detector

 

Product overview:

 

The protective mask dead space tester is used for the detection of the protective mask dead space, that is, the volume fraction of CO2 in the inhaled gas.

 

Equipment advantages:

 

1. The test process is completely controlled by a computer program, which realizes automatic detection, automatic recording, and automatic calculation of the change of the carbon dioxide concentration value of the inhaled gas during the entire test process. The operation is simple and easy to use.

2. There is no need to adjust the breathing frequency and the amount of breathing during the test. The breathing frequency and the amount of breathing can be changed by simple parameter setting operations on the computer. The adjustment is very convenient and accurate.

3. The one-way valve that controls the breathing channel is automatically controlled by the ventilator using a solenoid valve group, which is completely synchronized with the action of the ventilator, making the detection result more accurate.

4. All data of the test process is automatically saved in the computer, and a test report is automatically generated. The data of the entire process can be viewed through the computer at any time, and a report of the test results can be printed at any time.

 

Technical parameters:

 
Name Specifications
Simulated breathing frequency 10~40 times /min
Adjustable range of simulated tidal volume 0.5~3.0L/min
Volume fraction of the carbon dioxide gas source 5.0±0.1%
Range of carbon dioxide flowmeter ≥ 40L/min
Range of carbon dioxide analyzer ≥ 12%, accuracy ≥ 0.1%
Electric fan Wind speed 0.5m/s
Breathing frequency 20 times/ min
Breathing tidal volume 1.5L
Power AC220V 50Hz
Dimensions 980mm*820mm*1400mm