Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control

Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control

MOQ: 1
Price: Negotiable
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN9913
Test Station:
16 Station
Control Mode:
PLC Control
Voltage Regulator:
0 ~ 300V, 3KW
Test Cycles:
0-999999
Power-on Time Setting:
0-99H99M99S
Power-off Time Setting:
0-99H99M99S
Equipment Power:
AC220V, 50HZ, 1KW
Sample Power:
AC220V, 50HZ, 10KW
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
10 Sets Per Month
High Light:

Luminaires Thermal Aging Rack

,

PLC Luminaires Thermal Aging Rack

Product Description

 

Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control

 

Product Information For Luminaires Thermal Aging Rack:

 

Luminaires thermal aging rack is used for light source and lamp aging life test. The equipment adopts PLC programming control, which can control the lamp aging time and cycle time, etc. It is divided into 3 layers of independent control for various luminaires test requirements. It is equipped with 3 sets of independent voltage regulators, and the voltage values can be display independently.

 

Technical Parameters For Luminaires Thermal Aging Rack:

 

 

 

1. Rack structure: It is divided into three layers, the upper layer is configured with 30 pieces of E27 lamp holders for testing the E27 luminaires, the middle layer is configured with 16 pieces of terminals for testing luminaires are powered directly with a connection to the power cables, and the lower layer is configured with 16 pieces of universal sockets for testing luminaires are powered through a plug.

 

2. Rack material: made of painted sheet metal, with universal feet at the bottom.

 

3. Rack dimensions are approx.: L2600mm*W700mm*H1800mm

 

4. Voltage regulator: 0 ~ 300V, 3KW

 

5. Control: 3 independent voltage adjustment and displaying, 3 independent setting of aging cycles.


a) Test cycles setting: 0-999999.
b) Power-on time setting: 0-99H99M99S.
c) Power-off time setting: 0-99H99M99S.

 

6. Operation: Weinview 7-inch color touch screen.

 

7. PLC: Mitsubishi PLC.

 

8. Voltmeter: Taiwan CW Instrument

 

9. All sample wiring is high temperature resistant.

 

10. Equipment power: AC220V, 50HZ, 1KW.

 

11. Sample power: AC220V, 50HZ, 10KW.

 

Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control 0
 
Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control 1
 
Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control 2
products
PRODUCTS DETAILS
Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control
MOQ: 1
Price: Negotiable
Standard Packaging: Plywood Case
Delivery Period: 30 Days
Payment Method: T/T
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN9913
Test Station:
16 Station
Control Mode:
PLC Control
Voltage Regulator:
0 ~ 300V, 3KW
Test Cycles:
0-999999
Power-on Time Setting:
0-99H99M99S
Power-off Time Setting:
0-99H99M99S
Equipment Power:
AC220V, 50HZ, 1KW
Sample Power:
AC220V, 50HZ, 10KW
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood Case
Delivery Time:
30 Days
Payment Terms:
T/T
Supply Ability:
10 Sets Per Month
High Light

Luminaires Thermal Aging Rack

,

PLC Luminaires Thermal Aging Rack

Product Description

 

Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control

 

Product Information For Luminaires Thermal Aging Rack:

 

Luminaires thermal aging rack is used for light source and lamp aging life test. The equipment adopts PLC programming control, which can control the lamp aging time and cycle time, etc. It is divided into 3 layers of independent control for various luminaires test requirements. It is equipped with 3 sets of independent voltage regulators, and the voltage values can be display independently.

 

Technical Parameters For Luminaires Thermal Aging Rack:

 

 

 

1. Rack structure: It is divided into three layers, the upper layer is configured with 30 pieces of E27 lamp holders for testing the E27 luminaires, the middle layer is configured with 16 pieces of terminals for testing luminaires are powered directly with a connection to the power cables, and the lower layer is configured with 16 pieces of universal sockets for testing luminaires are powered through a plug.

 

2. Rack material: made of painted sheet metal, with universal feet at the bottom.

 

3. Rack dimensions are approx.: L2600mm*W700mm*H1800mm

 

4. Voltage regulator: 0 ~ 300V, 3KW

 

5. Control: 3 independent voltage adjustment and displaying, 3 independent setting of aging cycles.


a) Test cycles setting: 0-999999.
b) Power-on time setting: 0-99H99M99S.
c) Power-off time setting: 0-99H99M99S.

 

6. Operation: Weinview 7-inch color touch screen.

 

7. PLC: Mitsubishi PLC.

 

8. Voltmeter: Taiwan CW Instrument

 

9. All sample wiring is high temperature resistant.

 

10. Equipment power: AC220V, 50HZ, 1KW.

 

11. Sample power: AC220V, 50HZ, 10KW.

 

Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control 0
 
Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control 1
 
Luminaires Thermal Aging Rack For Light Source And Lamp Aging Life Test PLC Control 2
Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.