Model Number
SN881-225L
Applied Standard:
IEC 62368-1
Clause:
5.4.1.5.3, 5.4.8
Temperature Range:
-40 °C ~+150°C
Humidity Range:
20%~98%RH
Heating Rate:
≧2-3°C/min
Cooling Rate:
≧0.7-1°C/min
Control:
PLC Control
Humidity Deviation:
±3%RH
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Standard Exporting Plywood Case
Delivery Time:
30 Days
Payment Terms:
L/C, T/T
Supply Ability:
5 Sets Per Month
High Light:

225L Humidity Test Chamber

,

IEC 62368-1 Humidity Test Chamber

,

PLC Humidity Test Chamber

Product Description

 

IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature and Humidity Test Chamber 225L

 

 

Product overview:

This temperature and humidity chamber is designed and manufactured according to the standard requirements of IEC 62368-1 clause 5.4.1.5.3, 5.4.8 and etc., IEC60335-1 clause 15, 29.3.3, Annex J etc.

This test chamber is used for cold, heat, humidity and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc. The purpose is to confirm the products reliability of storage and transportation under high and low temperature alternating heat and humidity.

 

Structure:

This machine adopts a closed chamber structure with the following features:

A. It has an extremely wide temperature and humidity control range to meet the various needs of users.

B. It adopts a unique balanced temperature adjustment and humidity control mode to adjust the ideal temperature and humidity environment. The heating and humidification capability are stable and balanced, and the temperature and humidity control are high-precision and high-stability.

C. Automatic selection of refrigeration circuit: The automatic control device has the ability of automatically starting the running refrigeration circuit according to the set value of temperature, can start the cooling directly under the high temperature state.

The refrigeration adopts the air-cooled condensing unit with fully enclosed compressor (imported).

D. The door is equipped with an observation window, which is convenient for observing the test state of the test sample.

 

Technical parameters:

 

Applied Standard IEC 62368-1
Clause 5.4.1.5.3, 5.4.8
Power Supply Single phase: AC220V ± 10%, 50Hz
Control & Operation PLC and touch screen intelligent control system

Chamber Size

 

Inner Size External Size
80L, WDH=400×400×500mm (Optional)

WDH=1000×870×1700mm

(Optional)

150L, WDH=500×500×600mm

(Optional)

WDH=1050×970×1750mm

(Optional)

225L, WDH=600×500×750mm WDH=1150×970×1900mm

408L, WDH=800×600×850mm

(Optional)

WDH=1350×1150×1950mm

(Optional)

800L, WDH=1000×800×1000mm

(Optional)

WDH=1450×1300×2100mm

(Optional)

 

1000L, WDH=1000×1000×1000mm

(Optional)

WDH=1470×1400×2100mm

(Optional)

Temperature Range -40 °C ~+150°C
Humidity Range 20%~98%RH
Temperature Resolution 0.1℃
Temperature Fluctuation ±0.5℃
Temperature Uniformity ±2℃
Humidity Deviation ±3%RH
Heating Rate ≧2-3°C/min
Cooling Rate ≧0.7-1°C/min
Temperature and Humidity Range Scheme IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature And Humidity Test Chamber 225L 0
IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature And Humidity Test Chamber 225L 1IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature And Humidity Test Chamber 225L 2

 

products
PRODUCTS DETAILS
IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature And Humidity Test Chamber 225L
MOQ: 1
Price: Negotiable
Standard Packaging: Standard Exporting Plywood Case
Delivery Period: 30 Days
Payment Method: L/C, T/T
Supply Capacity: 5 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN881-225L
Applied Standard:
IEC 62368-1
Clause:
5.4.1.5.3, 5.4.8
Temperature Range:
-40 °C ~+150°C
Humidity Range:
20%~98%RH
Heating Rate:
≧2-3°C/min
Cooling Rate:
≧0.7-1°C/min
Control:
PLC Control
Humidity Deviation:
±3%RH
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Standard Exporting Plywood Case
Delivery Time:
30 Days
Payment Terms:
L/C, T/T
Supply Ability:
5 Sets Per Month
High Light

225L Humidity Test Chamber

,

IEC 62368-1 Humidity Test Chamber

,

PLC Humidity Test Chamber

Product Description

 

IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature and Humidity Test Chamber 225L

 

 

Product overview:

This temperature and humidity chamber is designed and manufactured according to the standard requirements of IEC 62368-1 clause 5.4.1.5.3, 5.4.8 and etc., IEC60335-1 clause 15, 29.3.3, Annex J etc.

This test chamber is used for cold, heat, humidity and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc. The purpose is to confirm the products reliability of storage and transportation under high and low temperature alternating heat and humidity.

 

Structure:

This machine adopts a closed chamber structure with the following features:

A. It has an extremely wide temperature and humidity control range to meet the various needs of users.

B. It adopts a unique balanced temperature adjustment and humidity control mode to adjust the ideal temperature and humidity environment. The heating and humidification capability are stable and balanced, and the temperature and humidity control are high-precision and high-stability.

C. Automatic selection of refrigeration circuit: The automatic control device has the ability of automatically starting the running refrigeration circuit according to the set value of temperature, can start the cooling directly under the high temperature state.

The refrigeration adopts the air-cooled condensing unit with fully enclosed compressor (imported).

D. The door is equipped with an observation window, which is convenient for observing the test state of the test sample.

 

Technical parameters:

 

Applied Standard IEC 62368-1
Clause 5.4.1.5.3, 5.4.8
Power Supply Single phase: AC220V ± 10%, 50Hz
Control & Operation PLC and touch screen intelligent control system

Chamber Size

 

Inner Size External Size
80L, WDH=400×400×500mm (Optional)

WDH=1000×870×1700mm

(Optional)

150L, WDH=500×500×600mm

(Optional)

WDH=1050×970×1750mm

(Optional)

225L, WDH=600×500×750mm WDH=1150×970×1900mm

408L, WDH=800×600×850mm

(Optional)

WDH=1350×1150×1950mm

(Optional)

800L, WDH=1000×800×1000mm

(Optional)

WDH=1450×1300×2100mm

(Optional)

 

1000L, WDH=1000×1000×1000mm

(Optional)

WDH=1470×1400×2100mm

(Optional)

Temperature Range -40 °C ~+150°C
Humidity Range 20%~98%RH
Temperature Resolution 0.1℃
Temperature Fluctuation ±0.5℃
Temperature Uniformity ±2℃
Humidity Deviation ±3%RH
Heating Rate ≧2-3°C/min
Cooling Rate ≧0.7-1°C/min
Temperature and Humidity Range Scheme IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature And Humidity Test Chamber 225L 0
IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature And Humidity Test Chamber 225L 1IEC 62368-1 Clause 5.4.1.5.3, 5.4.8 Temperature And Humidity Test Chamber 225L 2

 

Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.