Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN774-8KV
Control Method:
Siemens PLC
Touch Screen:
7 Inch Weinview
Test Voltage:
100V-8000V Stepless Adjustable
Output Voltage:
AC/DC (switchable)
Voltage Stability:
±1%.
Electrode Thickness:
0.5mm
Electrode Material:
Stainless Steel
Chamber Material:
Stainless Steel
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
30 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
High Light:

8kv Tracking Index Test Chamber

,

IEC 60587 Tracking Index Test Chamber

Product Description

 

IEC 60587 8kv AC and DC High Voltage Tracking Index Stainess Steel Test Chamber

 

Product overview:

 

The high voltage tracking tester is suitable for testing electrical tracking and erosion resistance of electrical and electronic products, household appliances and their materials. Simulating at power frequency (48Hz-62Hz), using liquid contaminants and inclined plane samples, assessing the resistance to tracking and erosion of electrical insulation materials used under severe environmental conditions through measurement of resistance to tracking and erosion. This high voltage tracking tester is designed and manufactured according to IEC60587-2007 and GB_T 6553-2014.

 

Technical Parameters:

 

 

1. Electrode: 0.5mm thick, material: stainless steel.

2. The distance between the upper and lower electrodes: 50.0mm±0.1.

3. Test voltage: 100V-8000V stepless adjustable.

4. Voltage regulator: output: 0~250V can be adjusted.

5. Transformer for testing voltage: Maximum output voltage AC8000V & DC8000V.

6. When the loop current is 60mA, cut off the voltage output.

7. Test time: 6 hours.

8. Dropping accuracy: 0.2%.

9. Voltage stability: ±1%.

10. Judgment of tracking:

According to IEC60587-2007, apply voltage (2.5k V, 3.5k V and 4.5k V) to the sample, and drip the contaminated liquid at a certain flow rate, current under 60mA continues for 6H, if there is no overcurrent, the sample is qualified.

11. Drip device:

Adopt Rover precision peristaltic pump, the flow range is 0.00185 ~ 20 ml/min, the working speed is 0.1 ~ 50 rpm, the flow accuracy error: <0.2%. 12. Output voltage: AC/DC (switchable).

13. The number of experimental groups: five groups (during the test, one pump controls a group of drops, and does not affect each other during the test)

14. Control device:

Siemens PLC + Taiwan weinview touch screen control, precise control, simple operation, completely user-friendly design, automatic report generated at the end of the test, panel thermal printer can print the test results in time.

15. Chamber volume: 800L*750W*850H (mm); volume is 0.56m3.

16. Chassis: SUS304 stainless steel (brushed surface).

17. Sewage tank is made of 316 stainless steel, and a sealing device is equipped.

18. Instrument dimensions: 1250L*800W*1800H (mm).

19. Weight: about 200KG.

 

Main configuration:

 

No.: Name Specification
1 PLC Siemens
2 Touch screen Weinview, 7inch
3 Electrodes 0.5mm thick, made of stainless steel, 1 set
4 Voltage regulator Output: 0~250V can be adjusted
5 Transformer Maximum output voltage AC6000V and DC6000V
6 Drip pump LEAD FLUIDF precision peristaltic pump, flow rate range from 0.00185 to 20 ml/min, working speed from 0.1 to 50 rpm, flow rate accuracy error: <0.2%
 
How to configurate the contaminated liquid?
 
① Concentration requirement of contaminated liquid: Use distilled water to configure mass fraction (0.1±0.002)% analytically pure NH4CL (ammonia chloride) and mass fraction (0.02±0.002)% isooctylphenoxypolyethoxyethanol non-ion type wetting agent mixed solution.

②. Configuration method of contaminated liquid: Add 2000ml of distilled water to the measuring cup, weigh 2g NH4CL analytically pure solid and 0.4g of isooctylphenoxypolyethoxyethanol using a balance, then add to distilled water, and stir evenly with a glass rod.
 
IEC 60587 8kv AC DC High Voltage Tracking Index Test Chamber 0
 
products
PRODUCTS DETAILS
IEC 60587 8kv AC DC High Voltage Tracking Index Test Chamber
MOQ: 1
Price: Negotiable
Standard Packaging: Plywood
Delivery Period: 30 Days
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN774-8KV
Control Method:
Siemens PLC
Touch Screen:
7 Inch Weinview
Test Voltage:
100V-8000V Stepless Adjustable
Output Voltage:
AC/DC (switchable)
Voltage Stability:
±1%.
Electrode Thickness:
0.5mm
Electrode Material:
Stainless Steel
Chamber Material:
Stainless Steel
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
30 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
High Light

8kv Tracking Index Test Chamber

,

IEC 60587 Tracking Index Test Chamber

Product Description

 

IEC 60587 8kv AC and DC High Voltage Tracking Index Stainess Steel Test Chamber

 

Product overview:

 

The high voltage tracking tester is suitable for testing electrical tracking and erosion resistance of electrical and electronic products, household appliances and their materials. Simulating at power frequency (48Hz-62Hz), using liquid contaminants and inclined plane samples, assessing the resistance to tracking and erosion of electrical insulation materials used under severe environmental conditions through measurement of resistance to tracking and erosion. This high voltage tracking tester is designed and manufactured according to IEC60587-2007 and GB_T 6553-2014.

 

Technical Parameters:

 

 

1. Electrode: 0.5mm thick, material: stainless steel.

2. The distance between the upper and lower electrodes: 50.0mm±0.1.

3. Test voltage: 100V-8000V stepless adjustable.

4. Voltage regulator: output: 0~250V can be adjusted.

5. Transformer for testing voltage: Maximum output voltage AC8000V & DC8000V.

6. When the loop current is 60mA, cut off the voltage output.

7. Test time: 6 hours.

8. Dropping accuracy: 0.2%.

9. Voltage stability: ±1%.

10. Judgment of tracking:

According to IEC60587-2007, apply voltage (2.5k V, 3.5k V and 4.5k V) to the sample, and drip the contaminated liquid at a certain flow rate, current under 60mA continues for 6H, if there is no overcurrent, the sample is qualified.

11. Drip device:

Adopt Rover precision peristaltic pump, the flow range is 0.00185 ~ 20 ml/min, the working speed is 0.1 ~ 50 rpm, the flow accuracy error: <0.2%. 12. Output voltage: AC/DC (switchable).

13. The number of experimental groups: five groups (during the test, one pump controls a group of drops, and does not affect each other during the test)

14. Control device:

Siemens PLC + Taiwan weinview touch screen control, precise control, simple operation, completely user-friendly design, automatic report generated at the end of the test, panel thermal printer can print the test results in time.

15. Chamber volume: 800L*750W*850H (mm); volume is 0.56m3.

16. Chassis: SUS304 stainless steel (brushed surface).

17. Sewage tank is made of 316 stainless steel, and a sealing device is equipped.

18. Instrument dimensions: 1250L*800W*1800H (mm).

19. Weight: about 200KG.

 

Main configuration:

 

No.: Name Specification
1 PLC Siemens
2 Touch screen Weinview, 7inch
3 Electrodes 0.5mm thick, made of stainless steel, 1 set
4 Voltage regulator Output: 0~250V can be adjusted
5 Transformer Maximum output voltage AC6000V and DC6000V
6 Drip pump LEAD FLUIDF precision peristaltic pump, flow rate range from 0.00185 to 20 ml/min, working speed from 0.1 to 50 rpm, flow rate accuracy error: <0.2%
 
How to configurate the contaminated liquid?
 
① Concentration requirement of contaminated liquid: Use distilled water to configure mass fraction (0.1±0.002)% analytically pure NH4CL (ammonia chloride) and mass fraction (0.02±0.002)% isooctylphenoxypolyethoxyethanol non-ion type wetting agent mixed solution.

②. Configuration method of contaminated liquid: Add 2000ml of distilled water to the measuring cup, weigh 2g NH4CL analytically pure solid and 0.4g of isooctylphenoxypolyethoxyethanol using a balance, then add to distilled water, and stir evenly with a glass rod.
 
IEC 60587 8kv AC DC High Voltage Tracking Index Test Chamber 0
 