Send Message
products
PRODUCTS DETAILS
Home > Products >
28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber

28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber

MOQ: 1
Price: Negotiable
Standard Packaging: Plywood
Delivery Period: 20 Days
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN122602
Sample Flow Rate Of Channel A:
28.3 L/min
Sample Flow Rate Of Channel B:
28.3 L/min
Spray Flow:
(8~10)L/min
Pump Flow:
(0.006~3.0)mL/min
Front Pressure In Of Flowmeter A:
(-20~0)kPa
Front Pressure In Of Flowmeter B:
(-20~0)kPa
Aerosol Negative Pressure:
(-90~-120)Pa
Cabinet Negative Pressure:
(-50~-200)Pa
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
20 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
High Light:

10.4 inch Medical Material Tester

,

Bacterial Filtration Efficiency Test Chamber

Product Description

 

Face Mask Bacterial Filtration Efficiency (BFE) Test Chamber

 

Facial Mask Tester Bacterial Filtration Efficiency (BFE) Test Chamber 28.3 L/Min Sampling Flow

 

Product overview:

 

The main performance indicators of the mask bacterial filtration efficiency (BFE) tester not only meet the requirements of B.1.1.1 of YY0469-2011 Annex B bacterial filtration efficiency (BFE) test method, but also comply with the requirements stipulated in American ASTM 2100, ASTMF2101 and  European EN14683 standards.  Innovative improvements have been made on this basis. The simultaneous sampling method with dual gas channels has been used to improve the accuracy of sampling. It is suitable for the measurement and verification departments, scientific research institutes, mask manufacturing enterprises and other relevant departments to measure the filtering efficiency of mask bacteria.

 

Equipment Features:

 
1. Negative pressure experiment system to ensure the safety of operators
2. Built-in peristaltic pump in negative pressure cabinet, A / B two-way six-stage Andrsen sampler
3. Flow rate of peristaltic pump can be set
4. The spray flow rate of bacteria liquid of special microbial aerosol generator can be set
5. Good atomization effect
6. Embedded high-speed industrial microcomputer control
7. 10.4 inch industrial-grade high-brightness color touch screen
8. USB interface, support U disk data transfer
9. Built-in high-brightness lighting lamp
10. Built-in leakage protection switch to protect the safety of operators
11. The inner layer of stainless steel is integrally processed and formed, and the outer layer is sprayed with cold-rolled sheet
12. Insulation between inner and outer layers, flame retardant
13. Front opening and closing glass door, convenient for laboratory personnel to observe and operate
14. Removable bracket with adjustable bracket height
15. Support, mobile dual-use casters
 
Technical parameters:
 
Main Parameters Range Resolution Max. Allowed Error
Sample flow rate of channel A 28.3 L/min 0.1 L/min Better than ±2.5%
Sample flow rate of channel B 28.3 L/min 0.1 L/min Better than ±2.5%
Spray Flow (8~10)L/min 0.1 L/min Better than ±2.5%
Peristaltic Pump Flow (0.006~3.0)mL/min 0.001 ml/min Better than ±2.5%
Front Pressure in of Flowmeter A (-20~0)kPa 0.01kPa Better than ±2.5%
Front Pressure in of Flowmeter B (-20~0)kPa 0.01kPa Better than ±2.5%
Front Pressure of Spray Flowmeter (0~300)kPa 0.1kPa Better than ±2.5%
Aerosol Negative Pressure (-90~-120)Pa 0.1Pa Better than ±2.5%
Working Temperature (0~50)℃
Cabinet Negative Pressure (-50~-200)Pa
Data Storage Capacity >10000 groups
High Efficiency Air Filter Characteristics Filtration efficiency for particles above 0.3um ≥99.99%
Aerosol Generator Mass Median Diameter Average particle diameter (3.0 ± 0.3) um, geometric standard deviation≤1.5
Two-way 6-level Anderson Sampler Captures Particle Size Ⅰlevel>7um, Ⅱ level (4.7~7) um,Ⅲ level (3.3~4.7) um,Ⅳ level(2.1~3.3)um,Ⅴ level(1.1~2.1)um, Ⅵ level(0.6~1.1)um
Aerosol Chamber Specifications (Length 600 * diameter 85 * thickness 3) mm
Total Number of Positive Quality Control Sampler Particles (2200±500)cfu
Ventilation Flow of Negative Pressure Cabinet ≥5m³/min
Negative Pressure Door Size (Length 1000 * width 730) mm
Equipment Size (Length 1180 * Width 650 * Height 1300) mm
Bracket Size (Length 1180 * Width 650 * Height 600) mm, height adjustable within 100mm
Working Power Supply AC 220V±10%, 50Hz
Equipment Noise <65dB(A)
Equipment Weight Approx. 150kg
Equipment Power <1500W

 

28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber 0 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber 1

 

products
PRODUCTS DETAILS
28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber
MOQ: 1
Price: Negotiable
Standard Packaging: Plywood
Delivery Period: 20 Days
Payment Method: T/T, L/C, Western Union, MoneyGram
Supply Capacity: 10 Sets Per Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN122602
Sample Flow Rate Of Channel A:
28.3 L/min
Sample Flow Rate Of Channel B:
28.3 L/min
Spray Flow:
(8~10)L/min
Pump Flow:
(0.006~3.0)mL/min
Front Pressure In Of Flowmeter A:
(-20~0)kPa
Front Pressure In Of Flowmeter B:
(-20~0)kPa
Aerosol Negative Pressure:
(-90~-120)Pa
Cabinet Negative Pressure:
(-50~-200)Pa
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Plywood
Delivery Time:
20 Days
Payment Terms:
T/T, L/C, Western Union, MoneyGram
Supply Ability:
10 Sets Per Month
High Light

10.4 inch Medical Material Tester

,

Bacterial Filtration Efficiency Test Chamber

Product Description

 

Face Mask Bacterial Filtration Efficiency (BFE) Test Chamber

 

Facial Mask Tester Bacterial Filtration Efficiency (BFE) Test Chamber 28.3 L/Min Sampling Flow

 

Product overview:

 

The main performance indicators of the mask bacterial filtration efficiency (BFE) tester not only meet the requirements of B.1.1.1 of YY0469-2011 Annex B bacterial filtration efficiency (BFE) test method, but also comply with the requirements stipulated in American ASTM 2100, ASTMF2101 and  European EN14683 standards.  Innovative improvements have been made on this basis. The simultaneous sampling method with dual gas channels has been used to improve the accuracy of sampling. It is suitable for the measurement and verification departments, scientific research institutes, mask manufacturing enterprises and other relevant departments to measure the filtering efficiency of mask bacteria.

 

Equipment Features:

 
1. Negative pressure experiment system to ensure the safety of operators
2. Built-in peristaltic pump in negative pressure cabinet, A / B two-way six-stage Andrsen sampler
3. Flow rate of peristaltic pump can be set
4. The spray flow rate of bacteria liquid of special microbial aerosol generator can be set
5. Good atomization effect
6. Embedded high-speed industrial microcomputer control
7. 10.4 inch industrial-grade high-brightness color touch screen
8. USB interface, support U disk data transfer
9. Built-in high-brightness lighting lamp
10. Built-in leakage protection switch to protect the safety of operators
11. The inner layer of stainless steel is integrally processed and formed, and the outer layer is sprayed with cold-rolled sheet
12. Insulation between inner and outer layers, flame retardant
13. Front opening and closing glass door, convenient for laboratory personnel to observe and operate
14. Removable bracket with adjustable bracket height
15. Support, mobile dual-use casters
 
Technical parameters:
 
Main Parameters Range Resolution Max. Allowed Error
Sample flow rate of channel A 28.3 L/min 0.1 L/min Better than ±2.5%
Sample flow rate of channel B 28.3 L/min 0.1 L/min Better than ±2.5%
Spray Flow (8~10)L/min 0.1 L/min Better than ±2.5%
Peristaltic Pump Flow (0.006~3.0)mL/min 0.001 ml/min Better than ±2.5%
Front Pressure in of Flowmeter A (-20~0)kPa 0.01kPa Better than ±2.5%
Front Pressure in of Flowmeter B (-20~0)kPa 0.01kPa Better than ±2.5%
Front Pressure of Spray Flowmeter (0~300)kPa 0.1kPa Better than ±2.5%
Aerosol Negative Pressure (-90~-120)Pa 0.1Pa Better than ±2.5%
Working Temperature (0~50)℃
Cabinet Negative Pressure (-50~-200)Pa
Data Storage Capacity >10000 groups
High Efficiency Air Filter Characteristics Filtration efficiency for particles above 0.3um ≥99.99%
Aerosol Generator Mass Median Diameter Average particle diameter (3.0 ± 0.3) um, geometric standard deviation≤1.5
Two-way 6-level Anderson Sampler Captures Particle Size Ⅰlevel>7um, Ⅱ level (4.7~7) um,Ⅲ level (3.3~4.7) um,Ⅳ level(2.1~3.3)um,Ⅴ level(1.1~2.1)um, Ⅵ level(0.6~1.1)um
Aerosol Chamber Specifications (Length 600 * diameter 85 * thickness 3) mm
Total Number of Positive Quality Control Sampler Particles (2200±500)cfu
Ventilation Flow of Negative Pressure Cabinet ≥5m³/min
Negative Pressure Door Size (Length 1000 * width 730) mm
Equipment Size (Length 1180 * Width 650 * Height 1300) mm
Bracket Size (Length 1180 * Width 650 * Height 600) mm, height adjustable within 100mm
Working Power Supply AC 220V±10%, 50Hz
Equipment Noise <65dB(A)
Equipment Weight Approx. 150kg
Equipment Power <1500W

 

28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber 0 28.3 L/Min Medical Material Tester Bacterial Filtration Efficiency (BFE) Test Chamber 1

 