Conductors Undue Damage Checking Test Apparatus 10±2 RPM IEC 60884-1 Figure 11

Conductors Undue Damage Checking Test Apparatus 10±2 RPM IEC 60884-1 Figure 11

MOQ: 1 Set
Price: Negotiable
Standard Packaging: Standard Exporting Plywood Case
Delivery Period: 30 days
Payment Method: L/C, T/T
Supply Capacity: 20 Sets / Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate(cost additional )
Model Number
SN2111
Standard:
IEC60884 Clause 12.2.5, Figure 11
Test Sample:
Terminals With Screw Clamping
Rotate Rate:
10±2 RPM
Test Height:
260, 280, 300, 320mm
Gyration Diameter:
75mm
Bushing Diameter:
6.5, 9.5, 13, 14.5mm
Minimum Order Quantity:
1 Set
Price:
Negotiable
Packaging Details:
Standard Exporting Plywood Case
Delivery Time:
30 days
Payment Terms:
L/C, T/T
Supply Ability:
20 Sets / Month
High Light:

switch endurance tester

,

switch life testing machine

Product Description

 

IEC 60884-1 Figure 11 Conductors Undue Damage Checking Test Apparatus

 

Standard: IEC60884-1 clause 12.2.5, figure 11.

 

Application: It is used to check terminals with screw clamping shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s).

 

Test sample: Plugs and socket-outlets terminals.

 

Technical Parameters:

 

Model SN2111
Test rate 10±2 RPM
Diameter of gyration 75mm
Test times 0~9999
Test weights 0.3, 0.4, 0.7, 0.9, 1.4, 2kg
Test height 260, 280, 300, 320mm
Diameter of bushing 6.5, 9.5, 13, 14.5mm
Complied standards IEC60884-1, IEC60669-1
 

Test processes:

 

The terminal is placed in the test apparatus according to figure 11 and fitted with rigid, solid, stranded and/or flexible conductor(s), according to table 3 first with the smallest and then with the largest nominal cross-sectional area, the clamping screw(s) or nut(s) being tightened with the torque according to table 6.

Conductors Undue Damage Checking Test Apparatus 10±2 RPM IEC 60884-1 Figure 11 0

Where rigid stranded conductors do not exist, the test may be made with rigid solid conductors only. In this case, there is no need for further tests.
The length of the test conductor shall be 75 mm longer than the height (H) specified in table 9.
The end of the conductor is passed through an appropriate bushing in a plate positioned at a height (H) below the equipment, as given in table 9. The bushing is positioned in a horizontal plane such that its centre line describes a circle of 75 mm diameter, concentric with the centre of the clamping unit in the horizontal plane; the platen is then rotated at a rate of (10 ± 2) r/min.
The distance between the mouth of the clamping unit and the upper surface of the bushing shall be within ±15 mm of the height specified in table 9. The bushing may be lubricated to prevent binding, twisting, or rotation of the insulated conductor.
A mass as specified in table 9 is suspended from the end of the conductor. The duration of the test is approximately 15 min.
During the test, the conductor shall neither slip out of the clamping unit nor break near the clamping unit, nor shall the conductor be damaged in such a way as to render it unfit for further use.

 

Comparison table of the weight, height and bushing as below:

Nominal cross-sectional area of conductor ( mm²)

Diameter of bushing Hole

( mm)

Height (mm) Mass for conductor (kg)
0.5 6.5 260 0.3
0.75 6.5 260 0.4
1.0 6.5 260 0.4
1.5 6.5 260 0.4
2.5 9.5 280 0.7
4.0 9.5 280 0.9
6.0 9.5 280 1.4
10.0 9.5 280 2.0
16.0 13.0 300 2.9
  1. The Corresponding size with mm² see IEC 60999-1.
  2. The height:±15mm.
  3. If the bushing-hole diameter is not large enough, you can choose the larger one.
  4. 2.9Kg weights are composed of 2Kg weights and 0.9Kg weights
 
products
PRODUCTS DETAILS
Conductors Undue Damage Checking Test Apparatus 10±2 RPM IEC 60884-1 Figure 11
MOQ: 1 Set
Price: Negotiable
Standard Packaging: Standard Exporting Plywood Case
Delivery Period: 30 days
Payment Method: L/C, T/T
Supply Capacity: 20 Sets / Month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate(cost additional )
Model Number
SN2111
Standard:
IEC60884 Clause 12.2.5, Figure 11
Test Sample:
Terminals With Screw Clamping
Rotate Rate:
10±2 RPM
Test Height:
260, 280, 300, 320mm
Gyration Diameter:
75mm
Bushing Diameter:
6.5, 9.5, 13, 14.5mm
Minimum Order Quantity:
1 Set
Price:
Negotiable
Packaging Details:
Standard Exporting Plywood Case
Delivery Time:
30 days
Payment Terms:
L/C, T/T
Supply Ability:
20 Sets / Month
High Light

switch endurance tester

,

switch life testing machine

Product Description

 

IEC 60884-1 Figure 11 Conductors Undue Damage Checking Test Apparatus

 

Standard: IEC60884-1 clause 12.2.5, figure 11.

 

Application: It is used to check terminals with screw clamping shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s).

 

Test sample: Plugs and socket-outlets terminals.

 

Technical Parameters:

 

Model SN2111
Test rate 10±2 RPM
Diameter of gyration 75mm
Test times 0~9999
Test weights 0.3, 0.4, 0.7, 0.9, 1.4, 2kg
Test height 260, 280, 300, 320mm
Diameter of bushing 6.5, 9.5, 13, 14.5mm
Complied standards IEC60884-1, IEC60669-1
 

Test processes:

 

The terminal is placed in the test apparatus according to figure 11 and fitted with rigid, solid, stranded and/or flexible conductor(s), according to table 3 first with the smallest and then with the largest nominal cross-sectional area, the clamping screw(s) or nut(s) being tightened with the torque according to table 6.

Conductors Undue Damage Checking Test Apparatus 10±2 RPM IEC 60884-1 Figure 11 0

Where rigid stranded conductors do not exist, the test may be made with rigid solid conductors only. In this case, there is no need for further tests.
The length of the test conductor shall be 75 mm longer than the height (H) specified in table 9.
The end of the conductor is passed through an appropriate bushing in a plate positioned at a height (H) below the equipment, as given in table 9. The bushing is positioned in a horizontal plane such that its centre line describes a circle of 75 mm diameter, concentric with the centre of the clamping unit in the horizontal plane; the platen is then rotated at a rate of (10 ± 2) r/min.
The distance between the mouth of the clamping unit and the upper surface of the bushing shall be within ±15 mm of the height specified in table 9. The bushing may be lubricated to prevent binding, twisting, or rotation of the insulated conductor.
A mass as specified in table 9 is suspended from the end of the conductor. The duration of the test is approximately 15 min.
During the test, the conductor shall neither slip out of the clamping unit nor break near the clamping unit, nor shall the conductor be damaged in such a way as to render it unfit for further use.

 

Comparison table of the weight, height and bushing as below:

Nominal cross-sectional area of conductor ( mm²)

Diameter of bushing Hole

( mm)

Height (mm) Mass for conductor (kg)
0.5 6.5 260 0.3
0.75 6.5 260 0.4
1.0 6.5 260 0.4
1.5 6.5 260 0.4
2.5 9.5 280 0.7
4.0 9.5 280 0.9
6.0 9.5 280 1.4
10.0 9.5 280 2.0
16.0 13.0 300 2.9
  1. The Corresponding size with mm² see IEC 60999-1.
  2. The height:±15mm.
  3. If the bushing-hole diameter is not large enough, you can choose the larger one.
  4. 2.9Kg weights are composed of 2Kg weights and 0.9Kg weights
 