Programmable Multi-standard Leakage Current Tester 1000VA 2000VA LCD Display
Standards & Clauses:
The tester conforms to IEC 60601-1: 2005+A1:2012, IEC 60950-1: 2005+A1:2009+A2:2013, IEC 60065: 2014, IEC 61010-1: 2010+A1:2016, IEC 60990:2016 and etc.
Samples and Restrictions:
Household appliances, electrical accessories, lamps, medical appliances, information and communication equipment,etc.
Application:
Various types of laboratories, home appliance manufacturers, as well as institutions that conduct home appliance safety testing and certification, research institutes, etc.
Test Contents:
This tester can simulate following 6 types of MD networks:
■MD-A compliant to : IEC 60990
IEC 61010-1
■MD-B compliant to : IEC 60990
IEC 61010-1
IEC 60335-1
IEC 60950-1
IEC 60665
IEC 60598-1
■MD-C compliant to : IEC 60990
IEC 60598-1
■MD-D compliant to : IEC 61010-1
■MD-E compliant to : IEC 60950-1
IEC 61010-1
■MD-F compliant to : IEC 60598-1
Technical Parameters:
Model | SN2212L-1K | SN2212L-2K | SN2212L-3K | SN2212L-4K |
Input characteristics | Single-phase 50Hz, 60Hz 110 / 220Vac ± 10% | |||
Output Capacity | 1000VA | 2000VA | 3000VA | 4000VA |
Output voltage setting | 30.0V ~300.0V, Resolution: 0.1V / Step | |||
Current upper limit setting range | 0.1μA ~20.00mA | |||
Current lower limit setting range | 0.0μA~20.00mA | |||
Wave detection method | DC/AC/AC+DC/AC Peak | |||
Voltmeter |
(0.0-250.0) V Resolution: 0.1 V Accuracy: ± (2% of reading + 2V) |
(0.0-300.0) V Resolution: 0.1 V Accuracy: ± (2% of reading + 2V) |
||
Ammeter |
0.0uA-20.00mA Resolution: 0.1uA for 200.0μA range, 0.001mA for 2mA range, 0.01mA for 20mA range, Accuracy: ± (2% of reading + 2 words) |
|||
Test time |
(0.1-999.9) seconds, 0 = continuous |
(0.0,0.3~999.9)s, 0 = continuous |
||
Intervals |
(0.1-999.9) seconds, 0 = Test time is over, the tester stops automatically |
(0.0-999.9) seconds, 0 = Interval time off |
||
Rise time |
(0.1-999.9) seconds, 0 = rise time off |
(0.0-999.9) seconds, 0 = voltage rise time off |
MOQ: | 1 |
Price: | Customized |
Standard Packaging: | Plywood |
Delivery Period: | 30 Days |
Payment Method: | L/C, , T/T, Western Union, MoneyGram |
Supply Capacity: | 20 sets per month |
Programmable Multi-standard Leakage Current Tester 1000VA 2000VA LCD Display
Standards & Clauses:
The tester conforms to IEC 60601-1: 2005+A1:2012, IEC 60950-1: 2005+A1:2009+A2:2013, IEC 60065: 2014, IEC 61010-1: 2010+A1:2016, IEC 60990:2016 and etc.
Samples and Restrictions:
Household appliances, electrical accessories, lamps, medical appliances, information and communication equipment,etc.
Application:
Various types of laboratories, home appliance manufacturers, as well as institutions that conduct home appliance safety testing and certification, research institutes, etc.
Test Contents:
This tester can simulate following 6 types of MD networks:
■MD-A compliant to : IEC 60990
IEC 61010-1
■MD-B compliant to : IEC 60990
IEC 61010-1
IEC 60335-1
IEC 60950-1
IEC 60665
IEC 60598-1
■MD-C compliant to : IEC 60990
IEC 60598-1
■MD-D compliant to : IEC 61010-1
■MD-E compliant to : IEC 60950-1
IEC 61010-1
■MD-F compliant to : IEC 60598-1
Technical Parameters:
Model | SN2212L-1K | SN2212L-2K | SN2212L-3K | SN2212L-4K |
Input characteristics | Single-phase 50Hz, 60Hz 110 / 220Vac ± 10% | |||
Output Capacity | 1000VA | 2000VA | 3000VA | 4000VA |
Output voltage setting | 30.0V ~300.0V, Resolution: 0.1V / Step | |||
Current upper limit setting range | 0.1μA ~20.00mA | |||
Current lower limit setting range | 0.0μA~20.00mA | |||
Wave detection method | DC/AC/AC+DC/AC Peak | |||
Voltmeter |
(0.0-250.0) V Resolution: 0.1 V Accuracy: ± (2% of reading + 2V) |
(0.0-300.0) V Resolution: 0.1 V Accuracy: ± (2% of reading + 2V) |
||
Ammeter |
0.0uA-20.00mA Resolution: 0.1uA for 200.0μA range, 0.001mA for 2mA range, 0.01mA for 20mA range, Accuracy: ± (2% of reading + 2 words) |
|||
Test time |
(0.1-999.9) seconds, 0 = continuous |
(0.0,0.3~999.9)s, 0 = continuous |
||
Intervals |
(0.1-999.9) seconds, 0 = Test time is over, the tester stops automatically |
(0.0-999.9) seconds, 0 = Interval time off |
||
Rise time |
(0.1-999.9) seconds, 0 = rise time off |
(0.0-999.9) seconds, 0 = voltage rise time off |