Send Message
products
PRODUCTS DETAILS
Home > Products >
CISPR 15 Radiation Emission RE Electromagnetic Compatibility 30MHz-6GHz Test System

CISPR 15 Radiation Emission RE Electromagnetic Compatibility 30MHz-6GHz Test System

MOQ: 1
Price: Customized
Standard Packaging: Plywood
Delivery Period: 60 Days
Payment Method: L/C, , T/T, Western Union, MoneyGram
Supply Capacity: 1 set per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN664
Test Samples:
ISM, ITE And Others
Test Environmen:
Anechoic Chamber
Measuring Distance:
10m Or 3m
Frequency Range:
30MHz-6GHz
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood
Delivery Time:
60 Days
Payment Terms:
L/C, , T/T, Western Union, MoneyGram
Supply Ability:
1 set per month
High Light:

emc test systems

,

electromagnetic testing services

Product Description

CISPR 15 Radiation Emission RE Electromagnetic Compatibility EMI Test Systems

 

Standards & Clauses:

 

CISPR 11 / GB4824: Industrial, scientific and medical (ISM) radio-frequency equipment and similar equipment –Radio-frequency disturbance characteristics –Limits and methods of measurement
CISPR 12: Vehicles, boats and internal combustion engines—Radio disturbance characteristics—Limits and methods of measurement for the protection of off board receivers
CISPR 13 / GB13837: Sound and television broadcast receivers and associated equipment –Radio disturbance characteristics –Limits and methods of measurement
CISPR 14-1 / GB4343.1: Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus -Part 1: Emission
CISPR 15 / GB17743: Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 22 / GB9254: Information technology equipment – Radio disturbance characteristics –Limits and methods of measurement

 

Samples and Restrictions:

 

Engineering medical (ISM) equipment and information technology (ITE) equipment

 

Application:

 

Used to test EUT radiation emissions.

 

Test Principle:

 

CISPR 11, CISPR 32 and other standards, engineering medical (ISM) equipment and information technology (ITE) equipment, the need to open the premises or anechoic chamber 30MHz above the emission test.

 

Structure:

 

Main test equipment: receiver, EMI receiving antenna, preamplifier, EMC test software.
Test environment: anechoic chamber (not included in this system, optional, or customer should prepare it)

 

Use Environment​:

 

Power supply: 380V ± 10% 50 / 60Hz
Ambient temperature: 5 °C ~ +40 °C, there should be no high concentration of dust, corrosive gas, flammable and explosive objects

 

Technical Parameters:

 

Main Test Equipment Receiver, EMI receiving antenna, preamplifier, EMC test software.
Test Environment Anechoic chamber
Measuring Distance It refers to the distance between the point where the EUT is closest to the antenna and the projection of the center of the antenna on the ground. Priority is given to the 10 m method, optional 3 m method
Antenna Height The height of the antenna from the ground should be varied within the specified range to obtain the maximum reading that would occur when the direct and reflected waves are in phase. For measuring distances ≤ 10 m, the height of the antenna is preferably varied from 1 m to 4 m.
Frequency Range 30MHz-6GHz
Schematic Diagram CISPR 15 Radiation Emission RE Electromagnetic Compatibility 30MHz-6GHz Test System 0
 
products
PRODUCTS DETAILS
CISPR 15 Radiation Emission RE Electromagnetic Compatibility 30MHz-6GHz Test System
MOQ: 1
Price: Customized
Standard Packaging: Plywood
Delivery Period: 60 Days
Payment Method: L/C, , T/T, Western Union, MoneyGram
Supply Capacity: 1 set per month
Detail Information
Place of Origin
China
Brand Name
Sinuo
Certification
Calibration Certificate (Cost Additional)
Model Number
SN664
Test Samples:
ISM, ITE And Others
Test Environmen:
Anechoic Chamber
Measuring Distance:
10m Or 3m
Frequency Range:
30MHz-6GHz
Minimum Order Quantity:
1
Price:
Customized
Packaging Details:
Plywood
Delivery Time:
60 Days
Payment Terms:
L/C, , T/T, Western Union, MoneyGram
Supply Ability:
1 set per month
High Light

emc test systems

,

electromagnetic testing services

Product Description

CISPR 15 Radiation Emission RE Electromagnetic Compatibility EMI Test Systems

 

Standards & Clauses:

 

CISPR 11 / GB4824: Industrial, scientific and medical (ISM) radio-frequency equipment and similar equipment –Radio-frequency disturbance characteristics –Limits and methods of measurement
CISPR 12: Vehicles, boats and internal combustion engines—Radio disturbance characteristics—Limits and methods of measurement for the protection of off board receivers
CISPR 13 / GB13837: Sound and television broadcast receivers and associated equipment –Radio disturbance characteristics –Limits and methods of measurement
CISPR 14-1 / GB4343.1: Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus -Part 1: Emission
CISPR 15 / GB17743: Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 22 / GB9254: Information technology equipment – Radio disturbance characteristics –Limits and methods of measurement

 

Samples and Restrictions:

 

Engineering medical (ISM) equipment and information technology (ITE) equipment

 

Application:

 

Used to test EUT radiation emissions.

 

Test Principle:

 

CISPR 11, CISPR 32 and other standards, engineering medical (ISM) equipment and information technology (ITE) equipment, the need to open the premises or anechoic chamber 30MHz above the emission test.

 

Structure:

 

Main test equipment: receiver, EMI receiving antenna, preamplifier, EMC test software.
Test environment: anechoic chamber (not included in this system, optional, or customer should prepare it)

 

Use Environment​:

 

Power supply: 380V ± 10% 50 / 60Hz
Ambient temperature: 5 °C ~ +40 °C, there should be no high concentration of dust, corrosive gas, flammable and explosive objects

 

Technical Parameters:

 

Main Test Equipment Receiver, EMI receiving antenna, preamplifier, EMC test software.
Test Environment Anechoic chamber
Measuring Distance It refers to the distance between the point where the EUT is closest to the antenna and the projection of the center of the antenna on the ground. Priority is given to the 10 m method, optional 3 m method
Antenna Height The height of the antenna from the ground should be varied within the specified range to obtain the maximum reading that would occur when the direct and reflected waves are in phase. For measuring distances ≤ 10 m, the height of the antenna is preferably varied from 1 m to 4 m.
Frequency Range 30MHz-6GHz
Schematic Diagram CISPR 15 Radiation Emission RE Electromagnetic Compatibility 30MHz-6GHz Test System 0
 
Sitemap |  Privacy Policy | China Good Quality Electrical Appliance Testing Equipment Supplier. Copyright © 2019-2024 sinuotek.com . All Rights Reserved.